Purpose of instruction manual 

 

This instruction manual describes the features of the KAL 84 calibration device and 

provides guidelines for its use. 

 

Improper use of this instrument or failure to follow these instructions may cause injury 

or equipment damage.  All individuals responsible for operating this instrument must 

therefore be properly trained and aware of the hazards, and must carefully follow 

these operating instructions and the safety precautions detailed within. 

Contact the 

manufacturer if you do not understand any part of this instruction manual.

 

 

Handle this manual with care: 

  It must be readily available throughout the lifecycle of the instrument. 

  It must be provided to any individuals who assume responsibility for operating the 

instrument at a later date. 

  It must include any supplementary materials provided by the manufacturer. 

 

The manufacturer reserves the right to continue developing this instrument model 

without documenting such development in each individual case. The manufacturer 

will be happy to determine whether this manual is up-to-date.

 

 

Conformity

 

 

This instrument corresponds to the state of the art and meets all legal requirements 

set forth in EC directives as evidenced by the CE label.

 

 

 

 

© 2005

 

 

The manufacturer owns the copyright to this instruction manual. This manual contains 

data, instructions and drawings pertaining to the features and usage of this 

instrument; copying this manual in part or in full or distributing it to third parties is 

prohibited.

 

 

Содержание KAL 84

Страница 1: ...3554 12 2015 Instruction Manual KAL 84 Calibration Device halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Germany Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E Mail info halstrup wal...

Страница 2: ...6 2 2 User interfaces 6 2 2 1 The 4 digit LCD 7 2 2 2 ON OFF 7 2 2 3 Backlighting 7 2 2 4 Analog output 7 2 2 5 Units of pressure 7 2 2 6 Pressure ports 7 2 2 7 Purge valves 7 2 2 8 Automatic zero po...

Страница 3: ...le throughout the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary materials...

Страница 4: ...y technical personnel who are appropriately trained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections The instrument may only be operated...

Страница 5: ...Symbols The symbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards WARNING This warns you of a potential hazard that c...

Страница 6: ...strument ideal for use in assembling pressure transducers as it allows the transducers to be calibrated on site Use of the KAL 84 for quality assurance purposes e g as a transfer standard for test equ...

Страница 7: ...e This feature allows the operator to toggle between 2 units of pressure e g Pa and mmHg A red LED indicates the units used 2 2 6 Pressure ports These ports are for connecting the test object to the K...

Страница 8: ...strument is run from the power adapter even if the KAL 84 is not turned on Because the battery may or may not be fully charged upon delivery we recommend charging the battery before start up The KAL 8...

Страница 9: ...A manual pump can quickly generate high levels of pressure which can destroy the instrument Caution is particularly advised when using instruments with low measurement ranges 5 Replacing the battery...

Страница 10: ...t least once a year A halstrup walcher certificate of linearity or a calibration certificate from a testing facility accredited by Germany s National Accreditation Body DAkkS is available upon request...

Страница 11: ...arting point setting 0 2 1 Digit for 1kPa measurement range 50kPa or 0 5 1 Digit Ambient conditions medium air all non aggressive gases operating temperature 10 C to 40 C storage temperature 10 C to 7...

Страница 12: ...ontact with measurement medium beryllium bronze CuBe2 Araldite CY236 HY988 Mu metal nickel alloy Loctite 242e Brass CuZn39Pb3 Carbonyl iron Aluminum AlCuMgPb AlMg3 KEL FPM fluorinated rubber Silicon t...

Страница 13: ...KAL 84 Instruction Manual 13 KAL 84 Instruction Manual 9 Dimension drawing 7100 003554_KAL84 doc 14 12 2015 Me...