![Halstead iHeat 24c Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/halstead/iheat-24c/iheat-24c_user-instructions_3433149005.webp)
5
55
55
© Halstead Boilers Ltd 2008
correct
pressure
value
flow/return
pipe
control
valve
temporary
connection
control
valve
supply
pipe
double
check valve
fig. 2
fig. 2
fig. 2
fig. 2
fig. 2
2.0
2.0
2.0
2.0
2.0 How to ...
How to ...
How to ...
How to ...
How to ...
fig. 3
fig. 3
fig. 3
fig. 3
fig. 3
COLOUR
COLOUR
COLOUR
COLOUR
COLOUR
FREQUENCY
FREQUENCY
FREQUENCY
FREQUENCY
FREQUENCY
FAULTS/STATUS
FAULTS/STATUS
FAULTS/STATUS
FAULTS/STATUS
FAULTS/STATUS
ACTION REQ’D
ACTION REQ’D
ACTION REQ’D
ACTION REQ’D
ACTION REQ’D
Green
Green
Green
Green
Green
Flashing every 6-seconds
At stand-by with no faults
None
Flashing 8-times every second
SARA function
None
On every 0.5 second
Temporary fault
Wait
Yellow
Yellow
Yellow
Yellow
Yellow
On every 0.5 second
Service function
Contact service centre
On permanently
DHW fault
Contact service centre
R e d
R e d
R e d
R e d
R e d
On every 0.5 second
Safety shutdown and/or
Check pressure gauge
internal fault
Check gas supply
Leave 2-minutes and reset
appliance, if fault continues,
contact service centre
On permanently
Appliance overheat
Contact service centre
APPLIANCE LED STATUS INDICATOR
APPLIANCE LED STATUS INDICATOR
APPLIANCE LED STATUS INDICATOR
APPLIANCE LED STATUS INDICATOR
APPLIANCE LED STATUS INDICATOR
2.1
2.1
2.1
2.1
2.1
USE THE APPLIANCE FOR THE FIRST TIME
USE THE APPLIANCE FOR THE FIRST TIME
USE THE APPLIANCE FOR THE FIRST TIME
USE THE APPLIANCE FOR THE FIRST TIME
USE THE APPLIANCE FOR THE FIRST TIME
Before switching the appliance on please familiarise yourself
on how to isolate the appliance from the electricity, gas, and
water supplies. If in doubt contact your installer.
2.2
2.2
2.2
2.2
2.2
U
U
U
U
USE T
SE T
SE T
SE T
SE THE M
HE M
HE M
HE M
HE MODE SEL
ODE SEL
ODE SEL
ODE SEL
ODE SELECT
ECT
ECT
ECT
ECTOR SWI
OR SWI
OR SWI
OR SWI
OR SWITTTTTCH
CH
CH
CH
CH
Turn the mode selector switch to the OFF position, switch
on the electrical supply to the appliance. The green LED
should be flashing, you may now select either HOT WATER
ONLY or HEATING AND HOT WATER.
2.2.1
2.2.1
2.2.1
2.2.1
2.2.1
OB
OB
OB
OB
OBTTTTTAIN HO
AIN HO
AIN HO
AIN HO
AIN HOT W
T W
T W
T W
T WA
AA
A
ATTTTTER
ER
ER
ER
ER
By turning on a hot water outlet (tap) the boiler will fire to
deliver hot water.
The appliance will have been commissioned by your installer
to deliver hot water at both a reasonable temperature and
flow rate, should you wish to alter the temperature of the
hot water, simply change the setting of the DHW temperature
selector and/or change the flow of water as it comes out of
the tap. Please consult your installer for further advice if
required.
2.2.2
2.2.2
2.2.2
2.2.2
2.2.2
OBTAIN CENTRAL HEATING
OBTAIN CENTRAL HEATING
OBTAIN CENTRAL HEATING
OBTAIN CENTRAL HEATING
OBTAIN CENTRAL HEATING
When the time clock is in an ‘on’ position, and the room
thermostat – if fitted – is calling for heat, the boiler will
fire to provide central heating.
2.3
2.3
2.3
2.3
2.3
R
R
R
R
RE-PR
E-PR
E-PR
E-PR
E-PRES
ES
ES
ES
ESSURING T
SURING T
SURING T
SURING T
SURING THE S
HE S
HE S
HE S
HE SY
YY
YYSSSSSTTTTTEM
EM
EM
EM
EM
The system will need re-pressurising if the red LED is
illuminated and the pressure gauge is reading below 0.4bar.
Locate the filling valve and if necessary connect the loop
(fig. 2) slowly open the valve until you hear the water
entering the appliance. The red LED will go out first. Go on
with re-pressuring until the pressure shown on the
manometer is between 1 & 1.5 bar (fig. 3). The appliance
must not be operated until the system has been re-
pressurised. If in doubt contact your installer.
2.4
2.4
2.4
2.4
2.4
SHU
SHU
SHU
SHU
SHUT DO
T DO
T DO
T DO
T DOWN T
WN T
WN T
WN T
WN THE S
HE S
HE S
HE S
HE SY
YY
YYSSSSSTTTTTEM F
EM F
EM F
EM F
EM FOR SHOR
OR SHOR
OR SHOR
OR SHOR
OR SHORT P
T P
T P
T P
T PERIODS
ERIODS
ERIODS
ERIODS
ERIODS
The system can be shut down for short periods by simply
turning the mode selector to the OFF position. It is also
advisable to turn off the main water supply to the house.
2.5
2.5
2.5
2.5
2.5
SHU
SHU
SHU
SHU
SHUT DO
T DO
T DO
T DO
T DOWN T
WN T
WN T
WN T
WN THE S
HE S
HE S
HE S
HE SY
YY
YYSSSSSTTTTTEM F
EM F
EM F
EM F
EM FOR L
OR L
OR L
OR L
OR LONG P
ONG P
ONG P
ONG P
ONG PERIODS
ERIODS
ERIODS
ERIODS
ERIODS
If the house is to be left unoccupied for any length of time
– especially during the winter - the system should be
thoroughly drained of all water. The gas should be turned
off at the meter and the main water supply should be turned
off at the stopcock. If necessary contact your installer for
further advice.
2.6
2.6
2.6
2.6
2.6
CARE FOR THE APPLIANCE
CARE FOR THE APPLIANCE
CARE FOR THE APPLIANCE
CARE FOR THE APPLIANCE
CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp cloth. Do
not use any scourers or abrasive cleaners.
Содержание iHeat 24c
Страница 7: ......