Use Proper Tools

 

 

Always use proper tools which are in good 

working condition during the installation of the 

product. Using tools other than those listed 

could adversely affect the product and could 

result in property damage.

Failure to follow these instructions could 

result in personal injuries, water damage, and 

other damage to floors, pipes, walls, and other 

portions of your building or home.

1.5 Property Damage

Inspect Before Cutting

  

Make sure no electrical wiring or plumbing 

is present before cutting into a wall.

2. General Information

2.1  Installation / Use & Care Manual

Read all instructions carefully before starting the 

installation and familiarize yourself with the various 

parts of this product.

Remote Water Chillers are designed to reduce the 

temperature of potable water that is routed through 

the water chiller. The chiller is meant to be installed in 

a properly ventilated, non-visible location.

This manual contains Installation, Use & Care 

instructions for the SJ8GRN series Remote Chiller 

units. Followed carefully, these instructions will 

result in trouble-free installation of this Halsey Taylor 

product.

Any deviations, additions, and/or deletions from the 

described methods, without prior written approval 

of Halsey Taylor, will void the warranty covering this 

product. 

Make sure the installation and use of this product 

meets all local, state, and federal plumbing and 

electrical codes.

Unit must be installed properly by trained service 

person.

2.2  Disclaimer

The information contained in this Installation / Use & 

Care  Manual is given free of charge. It is based upon 

technical data which we believe to be reliable and is 

intended for use by persons having knowledge of this 

technical area at their own discretion and risk. Halsey 

Taylor assumes no responsibility for results obtained 

or damage incurred from the use of this material either 

in whole or in part by the buyer.

2.3  Serial Number Location

Please use the serial number located on the Remote 

Chiller unit when contacting us with questions 

concerning the installation of this product. 

 

2.4  Contact Information

General Information 

Halsey Taylor 

1333 Butterfield Road, Suite 200 

 

Downers Grove, IL 60515
Phone: 630.574.8484

 

Email: [email protected] 

Website: http://www.HalseyTaylor.com 

USA/Canada Customer Care  

Phone: 800.476.4106 

 

Email: [email protected]

International Customer Care  

Phone: 630.575.4755 

 

Email: [email protected]

Installation Services 

Phone: 800.952.8064

 

Email: [email protected]  

Website: http://www.HalseyTaylor.com/contact-us/

install

2.5  Notice of Changes

The information, specifications, and illustrations in 

this manual are based on the information that was 

available at the time this material was written and 

can change at any time. In keeping with our policy 

of continuing product improvement, Halsey Taylor 

reserves the right to change specification without 

notice. 

All dimensions are given in inches (") and millimeters 

(mm).

2.6  Warranty

This product is covered by a Limited Warranty and 

Halsey Taylor will not be held responsible for damage 

of any kind in connection with the installation of the 

product. 

Refer to the Halsey Taylor website 

 

http://www.HalseyTaylor.com

Содержание SJ8GRN

Страница 1: ...SJ8QGRN_1C 630 574 8484 Halsey Taylor 2000000697 Rev A 07 22 Page 1 SJ8GRN Refrigeration Package INSTALLATION CARE AND USE MANUAL ...

Страница 2: ...3 Installation Preparation Read Before Beginning Installation 7 4 Tools and Supplies 7 4 1 Tools Required 7 4 2 Installer Supplied Parts 7 4 3 Tools Items required but not provided 7 5 Ratings 7 5 1 SJ8GRN Series 7 6 Preparation 8 6 1 General Information 8 7 Installation Electrical Connection 8 8 Start Up 9 9 Service 9 9 1 Service Adjustments 9 9 1 1 Temperature Control 9 9 2 Service Inspection Cl...

Страница 3: ...followed by a signal word such as WARNING or CAUTION 1 3 Definitions DANGER The signal word that indicates a hazard with a high level of risk which if not avoided will result in death or serious injury WARNING The signal word that indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury CAUTION The signal word that indicates a hazard with a low le...

Страница 4: ...aintenance make sure the unit is unplugged and circuit breakers are turned OFF Prior to installation test for live circuits or wiring inside the wall before cutting or drilling into the wall Failure to follow these instructions could result in personal injuries water damage and other damage to floors pipes walls and other portions of your building or home CAUTION Follow all instructions related to...

Страница 5: ...son 2 2 Disclaimer The information contained in this Installation Use Care Manual is given free of charge It is based upon technical data which we believe to be reliable and is intended for use by persons having knowledge of this technical area at their own discretion and risk Halsey Taylor assumes no responsibility for results obtained or damage incurred from the use of this material either in wh...

Страница 6: ... 8 263mm 16 3 4 426mm 3 3 8 87mm C D 1 3 8 35mm 2 51mm A B 13 1 4 338mm 1 25mm LEGEND A 1 4 O D TUBE WATER OUTLET B 1 4 O D TUBE WATER INLET C TEMPERATURE ADJUSTMENT D ELECTRICAL USES HFC 134A REFRIGERANT Electric shock hazard Disconnect power before servicing unit WARNING ...

Страница 7: ...isk of water damage Thoroughly flush all water lines and fittings of all foreign matter before connecting to chiller If inlet pressure is above 100 psig 0 69 MPa a pressure regulator must be installed in water supply line Any damage caused by the water pressure outside its rated pressure is not covered by warranty 4 Tools and Supplies 4 1 Tools Required Tool Used For Phillips Screwdriver Remove el...

Страница 8: ... each side of chiller When mounting unit in a cavity or behind a wall maintain a minimum space of 4 102mm on each side 4 102mm on the top and a depth of 12 305mm 6 Water inlet is 3 8 10 mm O D unplated tube Contractor to supply connections as required 7 Connecting lines to be made of unplated copper Thoroughly flush all lines to remove all foreign matter before connecting to chiller If flushing do...

Страница 9: ...bly and return to service practices 9 2 1 Condenser Fan Motor Visually check and confirm the condenser fan turns freely If the condenser fan does not spin freely have an authorized service personnel to check and replace the fan 9 2 2 Ventilation Cabinet louvers and the condenser fins should be periodically cleaned with a brush air hose or vacuum cleaner Cleaning should be done twice each year or m...

Страница 10: ...BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Operation of Quick Connect Fittings Fig 2 Fig 3 NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 4 O D TUBE WATER INLET TO CHILLER 3 8 O D UNPLATED COP PER TUBE CONNECT COLD WATER SUPPLY Fig 1 WHT GND BLK FAN 3 1 2 5 M S C 1 2 3 COLD CONTROL WATER 6 RELAY OVERLOAD COMPRESSOR RUN CAPACITOR Wiring Diagram ...

Страница 11: ...All correspondence pertaining to any of the above water chiller or orders for repair parts MUST include model number and serial number of chiller name and part number of replacement part Kit Evap Replace Assy Cabinet Kit Condenser Drier Kit Fan Mtr Blade Nut Shroud Bracket Fan Mounting Panel Rear In line Strainer Kit Elbow 5 16 x 1 4 3 Pack Kit Heat Exchanger Drier Drier Compressor Service Pack Co...