background image

PAGE 5

SCWT14WQ*1K

98702C (Rev. D - 04/16)

ITEM NO.  PART NO. 

DESCRIPTION

15005C

51544C

101507531550

101453431640

102639931640

160270508640

28346C

26860C

26861C

26862C

35839C

36312C

35840C

35768C

75589C

192668451550

45696C

66581C

75561C

50986C

66798C

66811C

55880C

61314C

66203C

75494C

55996C

55913C

75588C

56159C

70682C

See Color Table

See Color Table

35843C

35844C

56092C

70683C

75583C

See Color Table

Nut-Regulator Retaining

Bubbler 

Push Button Stem

Cap Push Button

Drain Plug

Strainer Plate

Basin

Regulator Lever 

Pivot Bracket

Regulator Retaining Bracket

Cold Control

Compressor Service Pak

Overload

Relay Cover

Gasket

Power Cord

Tailpipe Assy

Heat Exchanger

Elbow - 3/8"

Regulator Holder

Condenser Assy

Evaporator

Regulator Mounting Bracket

Regulator

Drier

Check Valve

Strainer

Adaptor-Drain W/O Holes

Nut - Slip Joint 1-1/4

Nipple - Bubbler

Tee - 1/4

Side Panel - Right

Side Panel - Left

Relay

Capacitor

Poly Tubing (Cut To Length)

Union - 1/4

Elbow - 5/16" x 1/4"

Front Panel

401536248410

401536242830

401536348410

401536342830

401507448410

401507442830

RIGHT PANEL

FRONT PANEL

LEFT PANEL

*INCLUDES RELAY & OVERLOAD.  IF UNDER WARRANTY, REPLACE 

WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.

NOTE:  All correspondence pertaining to any of the above water coolers or 

orders for repair parts MUST include Model No. and Serial No. of cooler, 

name and part number of replacement part.

ITEMIZED PARTS LIST

1

2

3

4

5

6

7

8

9

10

11

*12

13

14

15

16

**17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

NS

NS

FIG. 6

CONDENSER WATER VALVE ADJUSTMENT

The condenser water valve is factory preset for a 

condenser water outlet temperature of 95° to 105° F.

If actual temperature varies greatly from this, readjust water 

flow rate at the valve using the following procedures.

1. 

START UP COMPRESSOR

This can be accomplished by depressing the cooler   

push button (See Fig. 1 - Item 4).  Keep water 

running during the entire readjustment procedure.

        

2.      

ADJUSTMENT CONDENSER WATER VALVE

Adjust valve by rotating adjustment stem.  Rotating stem   

clockwise will increase water flow.  

Counterclockwise rotation will decrease water flow.   

Increasing water flow will result in a lower 

condenser outlet temperature, while decreasing water   

flow will result in a higher outlet temperature.  

Proper adjustment is attained when condenser outlet  

temperature is 95° to 105° F. 

 

 

 

      

**Includes Items 15, 28 & 29

Platinum (PV)

Stnlss Stl (SS)

COLOR

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.