background image

Page 5

98986C  (Rev. M - 12/17)    

HTHBHVR8-NF*1A, *2A, *3A    HTHBHVR-NF*A, *2A    HTHBHVR8*1A, *2A, *3A    HTHBHVR*A, *2A    

Fig. 4

 

Note:  Screw the locknut hand tight to seal

Fig. 5

BOTTLE  FILLER  INSTALLATION

(FOR NON-FILTERED AND FILTERED HVR MODELS)

1)    

Remove wall mounting plate

 from Cooler. Install Wall Mounting Plate as per rough-in diagram (See rough-in on page 4).

     

NOTE:

 Mounting plate 

MUST

 be supported securely. Add fixture support carrier if wall will not provide adequate support. 

2)    

Install water cooler onto wall bracket

 and secure to wall. Connect drain and water inlet to cooler as required (See rough-in on page 4).

    

DO NOT

 connect power to cooler at this time or turn water supply on.

3)   

Remove HTHBHVR Bottle Filler

 from carton. Remove 3/8” to 1/4” reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler on water 

cooler basin and cut insulation from tube even with bottom of unit, remove this insulation from the 3/8” tube, but do not discard.  Feed the power cord and waterline through the 

hole on top of water cooler. Feed the Reset Button wire from circuit board down through the hole in the basin.  

      

NOTE:

 To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it.

4)   

With the power cord,

 waterline and reset button wires through the hole on top of water cooler place Bottle Filler on to mounting bracket on basin. (See Fig. 3). Make sure Bottle 

Filler is installed properly on the basin gasket.

5)   

Once Bottle Filler

 is installed on basin mounting bracket, tighten the two screws (supplied) one on each side of the Bottle Filler. Install Top Cover on Bottle Filler (See Fig. 3) with 

two mounting screws (supplied). Caution do not over tighten screws.

6)   

Install remaining tube insulation to the waterline

 from Bottle Filler. Connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” waterline with the 3/8” to 

1/4” union and short piece of poly tube that was previously installed to the tee at the evaporator outlet. 

7)    

For Filtered Model HTHBHVR coolers install filter cartridge:

 Remove filter from carton. Remove protective cap and attach filter to filter head by firmly inserting into head and 

rotating filter clockwise.

    

NOTE: 

If the existing plumbing rough-in locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler cabinet, the filter can be installed 

horizontally below the unit.  A retrofit kit is available to mount the filter beneath the cooler.

8)    

Turn water supply on

 and inspect for leaks. Fix all leaks before continuing.

9)    

Once unit has been inspected

 for leaks and if any leaks that are found are corrected, plug Bottle Filler and HTHBHVR unit into wall. Be sure to reinstall fuse to the circuit or 

switch the circuit breaker back to the “ON” position.

10) 

Once power is applied to Bottle Filler,

 the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.

11) 

Verify proper dispensing

 by depressing the button at the top of the Bottle Filler and verify water dispenses. Note: the first initial dispenses might have air in line which may 

     cause a sputter. This will be eliminated once all air is purged from the line.14)  

Once unit tests out

, install Lower Panel back on HTHBHVR water cooler. Unit is now ready for 

use.

MOUNTING BRACKET

FOR  FASTENING UNIT

TO WALL

TOP COVER

MOUNTING 

SCREWS

Fig. 3

MOUNTING SCREWS

DO NOT REMOVE

MOUNTING SCREWS

DO NOT REMOVE

BOTTLE FILLER

WATER COOLER

NOTE: TRIM PLATES MUST 

BE INSTALLED ON THE 

INSIDE OF THE BOTTLE 

FILLER SIDE PANEL SLOTS.

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

Содержание HydroBoost HTHBHVR8

Страница 1: ...2A HTHBHVR8 1A 2A 3A HTHBHVR A 2A Owners Manual IMPORTANT THIS IS AN INDOOR APPLICATION ONLY ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON Model HTHBHVR8 HTHBHVR8 HTHBHVR8 25 HTHBHVR8 2...

Страница 2: ...NES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A...

Страница 3: ...2A Uses HFC 134A refrigerant Note Danger Electric shock hazard Disconnect power before servicing unit Pictured is unit only without Bottle Filler 8 17 18 6 20 21 21 21 11 9 See Fig 7 10 4 5 1 4 See Fi...

Страница 4: ...m MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Fig 2 REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEN...

Страница 5: ...aterline with the 3 8 to 1 4 union and short piece of poly tube that was previously installed to the tee at the evaporator outlet 7 For Filtered Model HTHBHVR coolers install filter cartridge Remove f...

Страница 6: ...t scratching the basin place a towel or soft cloth over the entire basin when working above it 2 Loosen but DO NOT remove the two 2 Pinned Torx Head Screws from the sides of the Bottle Filler Remove t...

Страница 7: ...HTHBHVR8 NF 1A 2A 3A HTHBHVR NF A 2A HTHBHVR8 1A 2A 3A HTHBHVR A 2A PUSH BUTTON MECHANISM 32 17 17 33 17 17 17 18 26 31 13 1 25 Fig 7 Fig 8 17 14 14 14 14 15 22 Fig 9 VANDAL RESISTANT BUBBLER DETAIL...

Страница 8: ...unt and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG R...

Страница 9: ...again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS...

Страница 10: ...3 2 2 Fig 12 WIRING DIAGRAM 120 VOLT 220 VOLT SINGLE BI LEVEL MICRO SWITCH ACTIVATION Fig 10 Filter Installation Detail 28 27 C OM N O N C MAIN BOARD I R BOARD NOT USED LED BOARD GND SOLENOID RED POWE...

Страница 11: ...er 220V 60Hz Power Inlet Wire Assembly ITEM NO PART NO DESCRIPTION 220V 240V PARTS LIST Fig 14 220V 240V POWER INLET DETAIL 35 34 115V WIRING DIAGRAM 97446C 98777C 98775C 36322C 0000000238 75524C 9877...

Отзывы: