Page 3
HVRGRN8BL*1B HVRGRN8BLWF*1B HVRGRNDBL*B HVRGRNDBLWF*B
98660C (Rev. F - 01/17)
O
RI
FI
CE
HE
IG
HT
AL
TU
RA
D
EL
O
RI
FI
CI
O
HA
UT
EU
R
D
E
L'
O
RI
FI
CE
O
RI
FI
CE
HE
IG
HT
AL
TU
RA
D
EL
O
RI
FI
CI
O
HA
UT
EU
R
D
E
L'
O
RI
FI
CE
FI
NI
SH
ED
F
LO
O
R
PI
SO
A
CA
BA
DO
PL
AN
CH
ER
F
IN
I
RI
M
HE
IG
HT
AL
TU
RA
D
E
LA
C
O
RO
NA
HA
UT
EU
R
D
U
BO
R
D
C
D
A
B
F
25
1
/8
"
63
8m
m
20
1
/8
"
51
1m
m
18
3
/4
"
47
6m
m
13
7
/8
"
35
2m
m
C L
C L
4
1/
2"
11
4m
m
3
1/
2"
89
m
m
6
1/
4"
15
8m
m
1
1/
2"
38
m
m
10
"
25
4m
m
5" 12
7m
m
2
7/
16
"
63
m
m
20
3
/8
"
51
8m
m
37
1
/2
"
95
2m
m
E
E
F
6
1/
2"
16
6m
m
5/
16
"
(8
m
m
) D
IA
. (
10
H
OL
ES
)
8m
m
(1
0
AG
U
JE
RO
U
S)
8m
m
(1
0
TR
OU
S)
18
1
/1
6"
45
9m
m
5
3/
4"
14
6m
m
1
3/
8"
35
m
m
5
3/
4"
14
6m
m
1
3/
8"
35
m
m
1
3/
8"
35
m
m
1
3/
8"
35
m
m
12
5
/1
6"
31
2m
m
4
1/
8"
10
5m
m
8" 20
3m
m
18
5
/8
"
47
4m
m
27
"
68
6m
m
31
7
/8
"
81
0m
m
32
1
5/
16
"
83
7m
m
39
1
/2
"
10
03
m
m
2
5/
8"
67
m
m
HA
NG
ER
B
RA
CK
ET
FI
JA
DO
R
DE
S
U
SP
EN
SI
ON
SU
PP
O
RT
D
E
SU
SP
EN
SI
ON
*
5
3/
4"
14
6m
m
5
3/
4"
14
6m
m
6
3/
4"
17
3m
m
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W
ATER SUPPL
Y LOCA
TION 3/8 O.D. UNPLA
TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY
OTHERS) 3 IN. (76
mm
) MAXIMUM OUT FROM W
ALL
La UBICACION 3/8 O RECOMENDADA
de
ABASTECIMIENT
O DE
AGUA. D. El
TUBO del COBRE de UNPLA
TED CONECT
A
TALONARIO CON
AP
AGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA
DE
PARED
L’O.D de 3/8 d’EMPLACEMENT
DE PROVISION D’EAU RECOMMANDE. LE
TUBE DE CUIVRE DE UNPLA
TED CONNECTE STUB
AVEC ETEINT
(P
AR LES
AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU
MUR
B = RECOMMENDED LOCA
TION FOR W
ASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM W
ALL
UBICACIÓN RECOMENDADA
P
ARA
EL
DRENAJE DE SALIDA
DE
AGUA, DE 1-1/2” DE DIÁMETRO.
El
TALONARIO 2 FUERA
DE P
ARED
EMPLACEMENT
RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SOR
TIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/2 TRAP
NOT FURNISHED
PURGADOR DE 1-1/2 NO PROPORCIONADO SIPHON 1-1/2 NON FOURNI
D = ELECTRICAL
SUPPL
Y (3) WIRE RECESSED BOX
CAJA
RECESIV
A DE
ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENT
ATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILA
TION BY
MAINT
AINING 6” (152
mm
) (MIN.) CLEARANCE FROM CABINET LOUVERS T
O W
ALL.
ASEGURE UNA
VENTILACIÓN
ADECUADA
MANTENIENDO UN ESP
ACIO E 6” (152
mm
) (MÍN.) DE HOLGURA
ENTRE LA
REJILLA
DE VENTILACIÓN DEL
MUEBLE
Y LA
P
ARED
ASSUREZ-VOUS UNE BONNE VENTILA
TION EN GARDANT
6” (152
mm
) (MIN.) ENTRE LES ÉVENTS DE L
’ENCEINTE ET
LE MUR.
F = 7/16 BOL
T HOLES FOR F
ASTENING UNIT T
O W
ALL
AGUJEROS DE LAS
TUERCAS DE 7/16 P
ARA
SUJET
AR LA
UNIDAD
A LA
P
ARED
TROUS D’ÉCROUS 7/16 POUR FIXER L
’APP
AREIL
AU MUR
FIG. 2
* * *
ADA
REQUIREMENT
REQUISIT
O DE
A.D.A.
EXIGENCE
ADA
REDUCE HEIGHT
BY
3” FOR INST
ALLA
TION OF CHILDREN’S
ADA
COOLER