IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN 

AUTHORIZED SERVICE PERSON

HANGER BRACKETS & TRAP 

INSTALLATION

1)  Remove hanger bracket fastened to back of cooler by removing one (1) screw.

2)  Mount the hanger bracket and trap as shown in Figure 2.  

NOTE:

  Hanger Bracket MUST be supported securely.  Add fixture support carrier if wall 

will not provide adequate support.

IMPORTANT:

•  6-1/4 in. (159mm) dimension from wall to centerline of trap must be maintained for

• 

proper fit.

• 

Anchor hanger securely to wall using all five (5) 1/4 in. dia. mounting holes.

3)  Install straight valve for 3/8” O.D. tube.

INSTALLATION OF COOLER

4)  Hang the cooler on the hanger bracket.  Be certain the hanger bracket is engaged properly 

in the slots on the cooler back as shown in Figure 2.

5)  Loosen the two (2) screws holding the lower front panel at the bottom of cooler base 

and two (2) screws at the top 

(Use torx bits sold separately)

.  Remove the front panel 

and set aside.

6)  Connect water inlet line--See Note 4 of General Instructions.

7)  Remove the slip nut and gasket from the trap and install them on the cooler waste line 

making sure that the end of the waste line fits into the trap.  Assemble the slip nut and 

gasket to the trap and tighten securely.

START UP

Also See General Instructions

8)  Stream height is factory set at 45-50 PSI.  If supply pressure varies greatly from this, 

adjust screw using the access hole in the pushbutton (insert screwdriver).  CW adjust-

ment will raise stream and CCW adjustment will lower stream.  For best adjustment, 

stream should hit basin approximately 6-1/2” (165mm) from bubbler.

Basin

Fig. 3

VANDAL RESISTANT BUBBLER DETAIL

1

Содержание HVRBLFR Series

Страница 1: ...Page 1 98353C Rev J 01 19 HVR8BLFR 1B HVRDBLFR C HVRBLFR Series Barrier Free Water Coolers Owners Manual ...

Страница 2: ...mponents shown above Other components and rough in are the same as shown 20 38 22 42 1 16 3 See Fig 3 25 25 45 40 21 43 19 11 32 37 45 45 12 21 49 33 45 37 8 32 33 21 45 42 16 16 2 1 4 4 48 13 See Fig 4 15 9 9 41 9 21 See Fig 4 Note Danger Electric shock hazard Disconnect power before servicing unit Uses HFC 134A refrigerant FIG 2 ...

Страница 3: ...5mm 1 3 8 35mm 12 5 16 312mm 4 1 8 105mm 8 203mm 18 5 8 474mm 27 686mm ADA REQUIREMENT 31 7 8 810mm 32 15 16 837mm 39 1 2 1003mm 2 5 8 67mm HANGER BRACKET FIJADOR DE SUSPENSION SUPPORT DE SUSPENSION 5 3 4 146mm 5 3 4 146mm 6 3 4 173mm LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF BY OTHERS 3 IN 76mm MAXIMUM OUT FROM WALL B RECOMM...

Страница 4: ...ger securely to wall using all five 5 1 4 in dia mounting holes 3 Install straight valve for 3 8 O D tube INSTALLATION OF COOLER 4 Hang the cooler on the hanger bracket Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 2 5 Loosen the two 2 screws holding the lower front panel at the bottom of cooler base and two 2 screws at the top Use torx bits s...

Страница 5: ...19 HVR8BLFR 1B HVRDBLFR C Fig 4 Refrigerated side shown 30 46 18 1 45 8 25 15 LH unit 13 RH unit 1 1 23 17 39 33 14 27 27 27 35 36 27 27 44 45 29 45 47 34 26 45 31 24 45 45 32 Items 31 24 also used on the LH unit 7 1 45 47 27 ...

Страница 6: ...H Unit Power Cord LH Unit Compressor Serv Pak Kit Electrical Relay Overload Cover Wasteline Refrig Unit Kit Regulator Holder Nut Wasteline LH unit Tubing Poly Cut To length Nut Slip Joint 1 1 4 Plug Drain 1 1 2CP Drier Evaporator Assembly Screw 10 x 1 2 Lg HHSM Kit Tee 1 4 3 Pack Gasket Drain Screen VR Kit Basin Replacement Stainless Steel Panel Bottom Dispenser Kit Push Button Assembly Nuts Sleev...