background image

98072C (10/04)

HBW8AQ*1L, 2L    HBW13AQ*1L, 2L    HBW*H-L-R

PAGE 3

FIG. 3

Stream height is factory set at 35 PSI. If supply pressure varies greatly from this,

remove items 24 and 25 and adjust screw on item 27. Clockwise adjustment will raise stream

and counter-clockwise adjustment will lower stream. For best adjustment, stream should hit

basin approximately 6-1/2" (165mm) from bubbler.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

HANGER BRACKETS & TRAP  INSTALLATION

1) Remove hanger brackets fastened to back of cooler by removing screws.

2) Mount the hanger brackets and trap as shown in Figure 2.

NOTE:

  Hanger Brackets and trap MUST be supported securely.  Add fixture support carrier if wall will not provide adequate

             support.

IMPORTANT:

- 5-1/2 in. (140mm) dimension from wall to centerline of trap must be maintained for proper fit.

- Anchor hanger securely to wall using all mounting holes.

3) Install straight valve for 3/8" O.D. unplated copper tube.

INSTALLATION OF COOLER

4) Hang the cooler on the hanger brackets.  Be certain the hanger brackets are engaged properly in the frame and wrapper.

5) Remove the access panel on the underside of the cooler and set it aside.

6) Connect water inlet line--See Note 4 of General Instructions.

7) Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste

line fits into the trap.  Assemble the slip nut and gasket to the trap and tighten securely.

START UP

Also See General Instructions

8) Replace the front panel and secure by retightening all screws.

CORRECT STREAM HEIGHT

FIG. 4

WRAPPER

27

25

26

24

28

29