EHWM14FP*A     EHWM17FP*A

Installation & Use Manual

Heavy Duty 14 Gauge Barrier Free Slimline

®

Freeze Resistant Fountains

EHWM14FP

EHWM17FP

Halsey Taylor Fountains are among the easiest to install Fountains on the market today. To assure you install 

these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING 

THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, 

AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future 

reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s) contains 

the Freeze Resistant Package(s) 

LKFRB1 

that are installed on an interior heated wall. The interior space must 

maintain a minimium temperature of 50° F (10° C). Refer to the Freeze Resistant Package for the rough-in 

dimensions for installation.

INSTALLER

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES 

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM 

THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN 

ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE 

WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN 

FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE 

FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

Содержание EHWM14FP A Series

Страница 1: ...LKFRB1thatareinstalledonaninteriorheatedwall Theinteriorspace must maintain a minimium temperature of 50 F 10 C Refer to the Freeze Resistant Package for the rough in dimensions for installation INSTA...

Страница 2: ...m 16 406mm 26 660mm 6 152mm 1 2 13mm 5 1 4 133mm 5 1 4 133mm 24 11 16 628mm 28 711mm 29 1 2 749mm WALL PLATE ASSEMBLY A B D C Finished Floor E 1 2 13mm LEGEND A 1 3 4 DIA 44mm HOLE FOR WASTE LINE B 7...

Страница 3: ...lready be framed for the fountain using dimensions shown in Fig 1 Shown dimensions pertain to installation location These dimensions are required for compliance with ANSI Standard A117 1 and ADA Frami...

Страница 4: ...ATER SUPPLY TUBE C 7 8 DIA 22mm HOLE FOR OPERATING CABLE D 1 4 DIA 6mm HOLES FOR MOUNTING PLATE TO WALL E 3 8 DIA 10mm HOLES FOR MOUNTING PLATE TO WALL Finished Floor 28 711mm 29 1 2 749mm 43 3 4 1111...

Страница 5: ...ded Tighten securely 4 Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide 5 Install freeze resistant box see box instructions 6 Replace bottom cover Adu...

Страница 6: ...PAGE 6 98402C Rev c 02 18 EHWM14FP A EHWM17FP A FIG 8 FIG 5 FIG 6 See Fig 6 See Fig 5 FIG 7 CABLE SHEATH ADJUSTMENT To Increase Free Play To Reduce Free Play...

Страница 7: ...elieve water pressure push in on dark gray collar while pulling out on the tubing See Figure 10 5 Connect drain and water supply lines to the freeze resistant fountain Refer to Figure 1 or Figure 3 fo...

Страница 8: ...VR BUBBLER ASSEMBLY PUSH BUTTON SLEEVE PUSH BUTTON GUIDE DRAIN PLUG 1 1 2 KIT DRAIN TAILPIPE SNAP BUSHING BUMPER REG VALVE ASSY FOUNTAIN ARM PUSH BUTTON EXTENSION POLY TUBING CUT TO LENGTH DRAIN GASKE...

Отзывы: