96974C (Rev. J - 5/04)
7120 FTN
PAGE 3
INSTALLATION INSTRUCTIONS
1.
Wall should already be framed for the fountain using the positioning dimensions shown in Figure 3.
Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight).
2.
Install
rough-in plumbing as shown in Figure 3. Run the supply water inlet line and connect to a service
stop (not provided). Turn on supply water and flush thoroughly.
3.
Remove bottom access panel from fountain basin and save the screws. Install the fountain to the wall
using (7) 5/16" bolts and washers (not provided). Bolts should be long enough to securely fasten the
fountain to the wall. Tighten securely, but do not over tighten. Over tightening will crack the fountain.
4.
Remove elbow from end of p-trap and attach it to drain tube. Reattach elbow to p-trap and cut waste
tube to required length using plumbing hardware and trap as a guide.
5.
Make water supply connections from service stop to the 3/8" O.D. unplated copper tube coming out of
the strainer. Turn on water supply and check for leaks. Newly installed water supply line should be
insulated after leak check is completed.
DO NOT SOLDER TUBES INSERTED INTO THE STRAINER
AS DAMAGE TO THE O-RINGS MAY RESULT.
6.
These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above
105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of
connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not
covered by warranty.
7.
Check stream height from bubbler. Stream height is factory set at 40-50 PSI. If supply pressure varies
greatly from this, remove items 8 & 12 (See Fig. 5) by loosening set screw (Item 17) and adjust the
screw on the regulator (Item 14). Clockwise adjustment will raise stream height and counter-clockwise
will lower stream height. For best adjustment stream height should be approximately 1-1/2" (38mm)
above the bubbler guard.
8.
Replace bottom access panel to fountain using the screws provided. Tighten securely.
CARE AND MAINTENANCE OF HALSEY TAYLOR MARBLYTE FOUNTAINS
1.
Marblyte
provides an extremely durable, nonporous surface which resists staining. Care is very simple.
Routine cleaning with a soft sponge or cloth, or with water or a non-abrasive aerosol foam cleaner, is all
that is normally needed to give many years of trouble free service. Cleaners left standing on the fountain
surface can dull the surface finish. Be certain to rinse all cleaning agents completely and polish with a
soft cloth.
2.
Harsh abrasive cleaners are not required and should not be used.
3.
Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple
scratches and stains. Cigarette burns can normally be removed without noticeable effect. Deeper
scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a green
scotchbrite pad.
4.
To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like
products will keep the finish looking like new.
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy:
Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits
may be removed from orifice with a small round file not over 1/8" diameter or a small diameter wire.
CAUTION:
Do not file or cut orifice materials.
2. Stream Regulator:
If orifice is free of material deposits, regulate flow according to instruction on page 3.
3. Actuation of Quick Connect Water Fittings:
Cooler is provided with lead-free connectors which utilize
an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar
while pulling on the tubing (See Figure 2). To insert tubing, push tube straight into the fitting until it
reaches a positive stop, approximately 3/4".