4420BFFR_FTN _A    LK4420BFFR_FTN_A

1000003686 (Rev. D - 03/20)

The following items are included with

the 4420BFFR Fountain

28467C

98901C

66346C

1000003814*

45476C

0000000325

45931C

98685C

66815C

66816C

97446C

75724C

97247C

98679C

98680C

98681C

1000003692

1000003693

98683C

98684C

40551C

98686C

1000003812*

1000003813*

28703C

28703C-LK

28091C-HT

1000005456

75565C

56092C

56123C

56307C

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

41

41a

41b

42

NS

NS

NS

NS

Basin

Kit - FR Push Button/Sleeve/Nuts

Tube-Drain

Cover - Round Plate

Tube - Drain

Kit - Drain Plug/Gasket

Plug - Outdoor Bottle Filler Drain

Kit - Hardware/Bolts/Nuts/Washers/Torx Screws

Tube - Drain

Tube - Drain (Arm Only)

Kit - VR Bubbler

Pinned Torx Screw - 1/4-20 x 3/4"

Kit - VR Torx Screws/Bit

Kit - Nozzle/Aerator/Gasket/Pin

Kit - Aerator/Key

Kit - Blank Bottle Filler Trim

Kit - LK4420BFFR Bottle Filler Trim

Kit - 4420BFFR Bottle Filler Trim

Kit - Plastic Drain

Kit - 90° Plastic Drain

Tailpipe - 1-1/4" X 6-7/8"

Kit - Bottle Filler Waterway

Panel - Access

Cover - Bottom 

Blank Nameplate Insert (only)

LK4420BFFR Nameplate Insert (only)

4420BFFR Nameplate Insert (only)

Aesthetic Collar

Fitting - Double Male Connector

Poly Tubing - 1/4" 

(Cut To Length) - To Bubbler

Poly Tubing - 1/8" 

(Cut To Length) - To Actuator

Poly Tubing - 3/8"

 (Cut to Length)

ITEM NO.

PART NO.

PARTS LIST

DESCRIPTION

PRINTED IN U.S.A.

Halsey Taylor – halseytaylor.com

Elkay – elkay.com 

FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816

1333 BUTTERFIELD RD, DOWNERS GROVE, ILLINOIS 60515

*select color option to complete part number

  NS = Not Shown

*FINISH COLOR OPTIONS – 

Choose color option to 

complete your model number, add as suffix example: 

4420BFFRK

EVG

Matte finish:       Evergreen = 

EVG

Gloss finish:

 

Beige = 

BGE

 

Gray = 

GRY

 

Terracotta = 

TER

 

Black = 

BLK

 

Orange = 

ORN

 

White = 

WHT

 

Blue = 

BLU

 

Purple = 

PUR

 

Yellow = 

YLW

 

Brown = 

BRN

 

Red = 

RED

Vandal-Resistant 

Bubbler Detail 

FIG. 10

BASIN

28

            

TROUBLESHOOTING AND MAINTENANCE

Insufficient Bubbler Flow:

 

Check that the shut-off valve is wide open.  Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve 

body.  Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve.

No Flow:

 

 Check for leaks in the air tubing going from the push button to the valve.  Make sure the air tubing compression nut is hand tight.  Disconnect air tube from 

push button.  Place finger over air outlet. Push button to test diaphragm.  Tighten diaphragm cap screws.  Replace diaphragm if necessary.

Continued Insufficient or Varied Height of Bubbler Flow:

 •

 Check for kinks in the tubing.

 •

 Remove the valve assembly from the  PVC column by carefully pulling up on the strap and connecting tubing at the same time. Check stream height from the    

    bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw on the regulator (Item 13, Fig. 5, Page 7). Clockwise  

    adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment stream height should be approximately. 1-1/2" (38mm) above 

     the bubbler guard. Replace the valve into the PVC column. Make sure the supply hose coils into the bottom of the PVC column without any kinks and double check  

    that the valve is positioned fully at the bottom of the PVC column.

Continuous Bubbler Flow:

 

Insure that push button is not obstructed and springs back to normal position. Remove four screws which secure plastic diaphragm block 

to valve body.  Pull plastic and rubber diaphragm assembly out of valve body.  Locate tiny hole in rubber diaphragm just under lip of plastic part.  Clean debris from this 

hole.  Inspect valve seat for grooves.  If valve seat was OK and diaphragm hole was free from debris, inspect rubber button located at center of floating steel disc in valve 

diaphragm block assembly.  If button is worn, turn disc over or replace it.  If diaphragm and seats are in good condition, stretch spring slightly.  Spring is located behind 

floating stainless steel plate.  Insure that air bleed port on valve plastic block assembly is not plugged.

Содержание 4420BFFR FTN A Series

Страница 1: ...4420BF1LFR MODEL 4420BF1UFR 4420BFFR Fountains are among the easiest to install Fountains on the market today To assure you install these models easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING ELECTRICAL AND OTHERAPPLICABLE CODES After installation save these instructions for future reference ...

Страница 2: ...installed in a non freezing area or below frost line Tubing must be cut to right length Do not coil any excess tubing or it will cause the valve to malfunction Do not pull up on lines coming out of the PVC column This raises the water valve above the frost line Use the nylon strap ref Item 10 to lift the unit to prevent damage to the valve General Installation Tips 1 Be sure to flush water supply ...

Страница 3: ... 8 INCH INSIDE DIA PVC PIPE TRIM TO DESIRED LENGTH SUPPLIED BY INSTALLER PVC 8 x 8 x 4 COMBINATION Y 1 8 BEND REDUCING ASSY SUPPLIED BY INSTALLER 4 PVC PIPE SUPPLIED BY INSTALLER 4 102mm 4 PVC 1 4 BEND SUPPLIED BY INSTALLER 36 MIN 914mm 60 MAX 1524mm FROST LINE 1 1 2 DRAIN TUBE SUPPLIED BY INSTALLER CLEANOUT PLUG FOR ACCESS SUPPLIED BY INSTALLER SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN...

Страница 4: ...Y LOCAL CODES A SEE DETAIL A 8 203mm 30 762mm 44 1 16 1119mm 14 9 16 371mm 19 483mm 27 1 8 689mm 10 254mm O 29 737mm 33 7 16 850mm O 14 356mm 4420SS BFFR1U 36 MIN 914mm 60 MAX 1524mm FROST LINE FIG 2 SUGGESTED SITE PREPARATION DETAIL FOR THE 4420BF1UFR FTN WHEN USING THE SANITARYFR2 VALVE 1 1 2 DRAIN TUBE SUPPLIED WITH FTN AIR GAP ASSY SUPPLIED WITH VALVE 1 1 2 DRAIN TUBE SUPPLIED BY INSTALLER Det...

Страница 5: ... 1 2 NPT CONNECTOR DRAIN LINE BY INSTALLER AS REQUIRED BY LOCAL CODES A SEE DETAIL A O 14 356mm 8 203mm 30 762mm 41 1 2 1054mm 19 483mm 27 1 8 689mm 3 76mm 37 3 16 945mm 14 9 16 371mm 29 737mm 10 254mm O 4420SS BFFR1L 36 MIN 914mm 60 MAX 1524mm FROST LINE LEGEND A ACCESS PANEL 8 X 10 B REMOVABLE BOTTOM COVER SUGGESTED SITE PREPARATION DETAIL FOR THE 4420BF1LFR FTN WHEN USING THE SANITARYFR2 VALVE ...

Страница 6: ...nsert the 1 4 O D tube s Labeled E F into the 1 4 union s provided with valve assembly Insert the 1 4 O D water lines coming from the fountain s into union s Trim any excess length Step 4 Insert the 1 4 O D tube Labeled G into the air gap assembly Step 5 Secure the 1 4 O D tube Labeled H to the waste line assembly This line is a vent line and should be open to the air LABEL A ON OFF CONTROL LINE F...

Страница 7: ...PAGE 7 4420BFFR_FTN _A LK4420BFFR_FTN_A 1000003686 Rev D 03 20 DETAIL B 16 6 3 2 4 12 15 14 7 7 SEE DETAIL B 8 15 Stream Height Adjustment 5 13 8 8 8 FIG 5 ...

Страница 8: ...RT NO Hex Nut 3 8 16 Bracket Regulator Holder Hex Nut 1 5 16 Dual Valve Regulator Holder Regulator Nut Poly Tubing 1 4 Cut To Length Poly Tubing 1 8 Cut To Length Canister Nylon Strap 6 ft Air Gap Assy Fitting 1 2 Union w Strainer Kit 1 0 GPM Regulator Fitting Elbow 1 4 Stem x 1 4 Tube Fitting Connector 1 4 x 1 4 NPTF Fitting Elbow 1 4 x 1 4 NPTF U Bolt Fitting Union 1 4 ITEM NO PARTS LIST The Fol...

Страница 9: ... of the fountain ensuring the vertical edge of the collar is upright and the curved edge sits below the mounting surface Mount bottle filler to arm with collar centered between the two pieces Install bottle filler to arm being sure drain tube is above mounting plate of filler Install filler onto fountain and secure with supplied mounting hardware 7 Connect water supply and fountain drain Connect d...

Страница 10: ... LK4420BFFR_FTN_A 1000003686 Rev D 03 20 25 29 21 37 37 37 25 32 25 ARM ONLY 27 26 31 33 24 42 34 FIG 9 Included with Sanitary Valve 18 23 22 28 25 30 35 35 19 19 41 41a 41b 40 40a 40b 23 34 38 39 20 36 23 23 18 25 30 FIG 8 ...

Страница 11: ... Insufficient Bubbler Flow Check that the shut off valve is wide open Verify minimum 20 PSI supply pressure Clean inlet strainer screen located in the valve body Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve No Flow Check for leaks in the air tubing going from the push button to the valve Make sure the air tubing compression nut is hand tig...

Отзывы: