background image

96893C (Rev. B - 2/00)

PAGE 3

ASSEMBLY

1. Assemble support brackets to the fountain by aligning holes in bracket with holes in cooler and fastening with

(4) #10 screws provided.

2. Slide drain tube into drain fitting and secure by sliding drain nut over drain tube and tightening nut to

drain fitting.

3. Attach bubbler to fountain by inserting bubbler nipple through the hole in the cooler top and securing

with the washer and nut provided.

INSTALLATION

1. This fountain is to be mounted on a smooth, flat, finished wall surface, with adequate support structure.

2. Establish rim height fountain is to be mounted.

3. Refer to rough-in for plumbing.

4. Locate and install trap. (Trap not included).

5. Install shut-off valve on building water supply. (Shut off valve not furnished).

6. Locate and install hanger bracket using 1/4" (10mm) lag screws or bolts. (Not included).

7. Install and center fountain on hanger bracket by slipping the back edge of the cooler top over the

flange on the hanger bracket. Secure fountain using 1/4" (10mm) minimum lag screws or bolts (Not

included).

CAUTION:

 This fountain is rated for inlet water pressure of 20-90 psi. Should the inlet water supply exceed

90 psi, a pressure reducing regulator should be used.

8. Connect fountain to building supply line by running a 3/8" (10mm) water line between the shut-off

valve and fountain.

9. Turn "ON" water supply and check all connections for leaks.

10. Adjust bubbler stream height. (See instructions below).

TROUBLE SHOOTING AND MAINTENANCE

Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be

removed from the orifice with a small round file not over 1/8" diameter or small diameter wire.

CAUTION: DO NOT

 file or cut orifice material.

Stream Regulator: If orifice is clean, regulate flow as stated below. If replacement is necessary, see parts list for

correct regulator part number.

STREAM HEIGHT ADJUSTMENT: 

Stream height is factory set

at 45-50 PSI. If supply pressure varies greatly from this, remove

items 16, and 17 (See figure 2) from bubbler assembly and

adjust the screw on the regulator (Item 20). Clockwise adjust-

ment will raise stream height and counterclockwise will lower

the stream height. A stream height of 1-1/2" (38mm) is recom-

mended.

FIG. 1

Отзывы: