17
CONNECTING
20 LBS. TANK
ADDED FEATURE
Your appliance is equipped with an adjustable low-pressure regulator. The
normal operating pressure is 11" water column and the lower operating pressure
available is 8.5" water column. When operating your appliance under normal
circumstances you will want to have the regulator set at the 11" water column
pressure. If you want to cook with slightly lower temperatures, then set the
regulator to the 8.5" water column setting. Depending on what temperature
setting you have the control knob set at will determine how much lower your
temperatures will be when using the lower pressure setting. Please see the
instructions on how to change from the 11" water column setting and back again.
1. Place LP tank on tank support bracket and secure with tank retention wire
or level, and stable surface.
2. Make sure burner valve is on off position.
3. LP tank should be in OFF position, if not turning wheel clockwise until stop.
4. Remove the protective cap from LP tank valve. Always use cap and strap
supplied with OPD valve.
5. DO NOT USE A POL TRANSPORT PLUG (plastic part with external threads)!
IT WILL DEFEAT THE SAFETY FEATURE OF THE VALVE.
6. The hose and regulator is equipped with Quick Connect. Align the insert
fitting on the regulator to the quick connect insert on the side of the Flat
Top Griddle. Pull back the spring-loaded coupling then push the into
insert firmly and release. The Quick Connect will snap in and lock in place.
CONNECTING HOSE + ADJUSTABLE
REGULATOR
20 LBS. TANK
8.5" Water Column
11" Water Column
11" Water Column
8.5" Water Column
11" Water Column
8.5" Water Column
Leak Check
WARNING
The LP tank used with this Flat Top Griddle must meet the following requirements:
• Use appliance only with LP (propane) gas and the regulator/valve assembly supplied.
• Installation must conform with local codes, or in their absence with National Fuel Gas Code, NFPA 54/ANSI Z223.1. Handling and
storage of LP cylinders must conform to LP Gas Code NFPA/ANSI 58.
•
Do not modify this appliance. Modifications will result in a safety hazard.
•
Apartment Dwellers: Check with management to learn the requirements and fire codes for using an LP Gas appliance at an apartment.
If allowed, use outside on the ground floor with a 10-foot clearance from walls or rails.