— 06 —
— 07 —
LIST OF FAULT CODES
Error
Code
Potential Cause
Solutions
High Temperature Warning
Please stop using the product and let it cool down
to room temperature until the icon disappears.
Low Temperature Warning
Please stop using the product until the icon disappears.
E01
Battery overvoltage
Please disconnect the charging cable and stop charging
E02
Battery undervoltage
Please disconnect the output and charge the device
E03
Inverter overheating
Please disconnect the output and wait 1-2 hours before
operation
E04
Abnormal input voltage
Please disconnect the charging cable
E05
Abnormal grid frequency
Please disconnect the charging cable
E06
Abnormal output voltage
Please contact customer service center
E07
AC and USB outputs are overloaded or
short-circuited
Please disconnect the output and check the electrical
equipment
E08
DC output is overloaded or short-circuited Please disconnect output
E09
Inverter failure
Please contact customer service center
E16
Charge overload
Please disconnect the output load
NOTE: When the DC load is abnormal, the system will automatically turn off the output
and will not show the fault code. Please disconnect the output and check the electrical
equipment then try again. When the USB load is abnormal, the corresponding output
power will be zero and the system will not show the fault code. Please disconnect the
outputs and check the electrical equipment, then try again.
① AC Input: During AC charging, this icon displays on the LCD.
② DC Input: When solar panel or DC source is connected to the DC/Solar input, the icon will turn on.
③Uninterruptible Power Supply (UPS): An uninterruptible power supply (UPS) is backup feature
that provides near instantaneous power in the event of an unexpected power failure or outage
which protect sensitive equipment from damage.
Devices with sensitive electronics like CPAP machines, some medical equipment, or computers
can benefit from the UPS feature. Instead of powering down during an outage, they maintain
performance despite the power outage.
④ Input Power: When the power station 1600 is being charged by AC, DC, or AC and DC, the total
charging power will be displayed under "INPUT". DC/Solar input takes priority over AC input,
when both are being used.
⑤ Input Time: Estimated time remaining to fully charged the internal battery.
⑥ AC Charge Mode: When displayed, AC slow charging is enabled, fast charge by default.
⑦ Cooling Fan Status: Cooling fan is on when the fan icon is displayed.
⑧ High Temperature Warning: When this icon illuminates, the internal temperature has reached
its high temperature limit, the unit will shut off automatically.
⑨ Low Temperature Warning: When this icon illuminates, the internal temperature has reached
its low temperature limit, the power station will not be able to provide output or being charged.
⑩ AC Output Frequency: Indicates the AC output frequency.
⑪ Wireless Icon: wireless output is on when this icon is displayed.
⑫ Discharge Time: Estimated time to fully discharge the internal battery.
⑬ Output Power: Shows the total output power.
Note: This value displays the real-time power consumption, it changes accordingly when
change in power consumption of the devices connected.
⑭ AC Output: This icon is on indicates the AC output is enabled.
⑮ DC Output: This icon indicates DC 12V and cigarette lighter socket is enabled.
⑯ USB Output: Indicates USB port is enabled.
⑰ Battery Level Indicator: Shows the battery charged level.