background image

2

Pressing a parameter symbol on your remote control, 

displays the saved value directly on the LCD-screen. 

Do not unlock first.

HOW TO USE THE LCD?

To adjust contrast, push and turn 

the grey button simultaneously. 

During normal function only.

Push to 

select

parameter

Scroll 

menu 

up-down

Select 

Back

 to 

return to previous 

menu or display.

Select 

More

 to go to 

next level: 

- basic settings

- advanced settings

- diagnostics

Negative display = active output

Select your language before 

entering the first LCD-menu. 

During the first 30 seconds after 

power-on of the sensor or later in 

the diagnostics menu. 

CHANGING A VALUE

Scroll 

values 

up-down

Push 

to save 

new value

VALUE CHECK WITH REMOTE CONTROL

DISPLAY DURING NORMAL FUNCTIONING 

FACTORY VALUE VS. SAVED VALUE

NAVIGATING IN MENUS

Scroll menu 

items

Push to enter 

the LCD-menu

new value is 
displayed

more values are 
displayed

current value is 
displayed 

displayed value = saved value

displayed value = factory value

Opening 

impulse

Presence

6

6

Enter password if 

necessary

Not during the first 

minute after power-on 

of the sensor.

CHANGING A ZIP CODE

Password

X X X X

ZIP code

ZIP code

ZIP code

ZIP code

ZIP code

ZIP code

ZIP code

ZIP code

ID #

H24 1 56-KG4

01 0 800/02

D

E24 1 56 KG4

01 0 800 02F

E24 1 56-KG4

01 0 800/02F

E

24 1 56-KG4

01 0 800/02F

H

24 1 56-KG4

01 0 800/02F

H24 1 56-KG4

01 0 800/02F

V

...

See application note on ZIP CODE

Validate the last digit in order to activate the new ZIP code:

- v = valid ZIP code, values will be changed accordingly

- x = invalid ZIP code, no values will be changed

- v/x = valid ZIP code, but from a different product. 

           Only available values will be changed.

Содержание BEA IXIO-DO1 I

Страница 1: ...nt knob 8 IR curtain angle adjustment knob OPENING PRESENCE SENSOR FOR AUTOMATIC INDUSTRIAL DOORS ACCESSORIES BA Bracket accessory CA Ceiling accessory CDA Curved door accessory RA Rain accessory 9 V...

Страница 2: ...FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value sa...

Страница 3: ...ing height of the sensor RED BLACK YELLOW YELLOW PINK PINK BLUE BLUE POWER SUPPLY OPENING PRESENCE NOT USED Depending on OUTPUT CONFIGURATION settings SENSOR ENGLISH IXIO DO1 I INSTALLATION GUIDE DOOR...

Страница 4: ...are not visible use the Spotfinder to locate the curtains The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR...

Страница 5: ...ifferent frequency increased immunities 1 curtain increased immunities redirection motion and presence factory values for radar immunity IR immunity IR number and redirection small large bi uni uni AW...

Страница 6: ...ned firmly Check position of cable and cover Increase the IR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check...

Страница 7: ...red green It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions Do not use aggressive products to clean the optical parts MAINTENANCE Fo...

Страница 8: ...contact current 100 mA Max contact voltage 42 V DC 30 V AC Holdtime 0 3 to 1 s Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20...