PROGRAMMING/
SETUP
The DK-12 has been programmed with factory-default settings. They are defined on the chart on page 5 and 6.
Please review the factory default settings before making any changes to the DK-12. If at any time the factory default
settings are appropriate for your application, you
DO NOT
have to change them. Only change the parameters that are
needed to customize your application.
With the help of data wires from LO-21/SS-21, the DK-12 has the capability of having two different memory locations:
DOOR OPEN and DOOR CLOSED. This feature enables the DK-12 to have different settings for the
pattern
selection
and the
sensitivity
in both the DOOR OPEN and DOOR CLOSED positions. All the other settings of the
DK-12 remain the same, independent of the position of the door.
DOOR OPEN & DOOR CLOSED memory location capabilities:
Dependent on door position
Independent of door position
Pattern selection
Relay hold time
Sensitivity Relay
mode
Auto learn time
Frequency
To program the DK-12, complete the following steps:
1.
Review the default settings.
2.
Determine which settings need to be changed.
3.
Change any setting that is independent of the door position (relay hold time, relay mode, auto learn,
frequency):
•
Remove left end cap.
•
Stand within 6’ of the left side of the sensor (do not be afraid to stand in the pattern area, but move
out of the pattern after making a change).
•
Point the remote control toward the opening (the receiver is located inside of DK-12 near terminal)
•
Press the function button followed by the number that corresponds to the desired setting.
4.
With the door in the CLOSED position, select the pattern size and the sensitivity
setting desired.
+ 1
5. Launch a DOOR CLOSED set-up with the remote: The LED will flash for
approximately 10 sec. and stop once the set-up is complete (see set-up for more
details).
6.
Place the door into hold open.
7.
With the door in the OPEN position, select the pattern size and the sensitivity
setting desired.
+ 2
8. Launch a DOOR OPEN set-up with the remote: The LED will flash for
approximately 10 sec. and stop once the set-up is complete (see set-up for more
details).
HELPFUL NOTES:
Once a set-up is launched the LED will flash at 5 Hz for approximately 10 seconds.
•
If the set-up is successful, the LED will go off and the detector will function normally.
•
If the set-up is not successful, the LED will continue to flash, but at a lower frequency of 2.5 Hz.
•
Possible problems during setup:
a.
If a person walks through the detection zone during the set-up, the set-up can be disturbed.
b.
If a very reflective object is placed within 32 inches from the DK-12, it can blind the detector and make
the set-up impossible.
c.
If the set-up that corresponds to the DOOR OPEN state is launched when the door is closed, the set-up
will be ignored and vice versa.
NOTE:
When two DK-12’s are installed on the same door, place the end cap on one DK-12 and program the
open DK-12. Once the first DK-12 is programmed, install its end cap and remove the second DK-12’s
end cap and repeat the programming procedure.
75.0082.05 20080125
Page 7 of 10