Fire detection and evacuation solutions that save lives.

 

MAN3070

-

5

 

Overview

 

XPander  is  a  range  of  addressable  multistate  detectors  and 

associated products developed to enhance the capabilities of 

our  addressable  range.  It  is  an  entirely  new  range  which  is 

connected to an XP95 or Discovery system via interface units 

wired to the loop. The interface units communicates with each 

other and with the field devices by means of radio signals. 

 

XPander can be incorporated into fire d e tection systems in 

heritage listed and architecturally sensitive buildings where the use of fire cables is either impracticable or undesirable.  It 

may also be used in sites with discrete buildings which need to be connected to a central control panel but where wiring 

might present problems. 

 

XPander has been tested and approved to the following standards: 

 

AS 7240 

-

7

 

optical smoke detector 

 

AS 7240 

-

5 —

 

heat detector 

 

AS 7240

-

25 —

 

components using radio links and system requirements 

 

...Ampac Wireless Detectors 

 

Contact points for enquiries and help:

 

 

 
 
 
 
 

All information in this guide is given in good faith but Ampac Fire Detectors cannot be held responsible for any omissions or 

errors. The company reserves the right to change the specifications of products at any time and without prior notice. 

 

General Queries

 

[email protected]

 

Phone Number Head Office (WA)

 

+61 8 9201 6100

 

Fax

 

+61 8 9201 6101

 

Website

 

ww.ampac.net

 

Содержание Ampac XPander

Страница 1: ...Product Guide Ampac addressable range expansion Wireless Minimises disruptions to buildings and occupants Enables rapid retrofit or temporary solution AS7240 25 Dual batteries for enhanced integrity...

Страница 2: ...either impracticable or undesirable It may also be used in sites with discrete buildings which need to be connected to a central control panel but where wiring might present problems XPander has been...

Страница 3: ...here to Use Optical Detectors 10 Detector Operating Principles 10 Technical Data 10 Contents XPander MultiSensor Smoke Detector 11 Where to Use MultiSensor Detectors 11 Detector Operating Principles 1...

Страница 4: ...comprises of two types of interface the Radio Hub and the Radio Communications Cluster or RCC The Radio Hub communicates with the control panel using the XP95 addressable two wire power and communica...

Страница 5: ...s for ease of installation Radio Communications Fire detection systems are life saving systems and must therefore be highly reliable in use Radio communications have been developed to a point where hi...

Страница 6: ...included in the booklet supplied with the survey kit and is also available from the Ampac website Training in the technique of surveying a site and designing an XPander system is mandatory Optical Sm...

Страница 7: ...arily developed to enable fully wireless fire alarm systems to be designed providing almost unlimited configuration and installation options With each Hub capable of supporting up to 500 field devices...

Страница 8: ...Diversity Interface transmits and receives signals via the integral Diversity Aerials which require no adjustment or maintenance This product is tested and approved to the AS7240 25 standards Item Nu...

Страница 9: ...adio Hub supports up to four loops of detection and alarm devices An integral LCD display is provided on the Radio Hub along with function buttons to allow programming and diagnostics to be carried ou...

Страница 10: ...articles over a wide range of angles The optical arrangement comprises an infrared emitter with a prism and a photo diode at 90 to the light beam with a wide field of view The detector s microprocesso...

Страница 11: ...Photo electric detection of light scattered by smoke particles over a wide range of angles The optical arrangement comprises an infra red emitter with a prism and a photo diode at 90 to the light beam...

Страница 12: ...measures the air temperature every 2 seconds A microprocessor stores the temperatures and compares them with preset values to determine whether a fixed upper limit the alarm level has been reached In...

Страница 13: ...are tested and approved to the following standards AS 7240 5 AS 7240 7 and AS 7240 25 Item Numbers 4111 1303 XPander Combined Sounder and Optical Detector Item Numbers 4111 1501 XPander Combined Sound...

Страница 14: ...e with three C size alkaline batteries which provide a working life of typically 3 5 years The three year life includes weekly tests and a half hour sounding in a fire condition The Sounder Visual Ind...

Страница 15: ...nual Call Points are supplied with a resettable operating element as standard The call point uses the priority interrupt feature to give a fast response on operation This product is tested and approve...

Страница 16: ...Output Unit All data is supplied subject to change without notice Specifications are given at 23 C and 50 relative humidity unless otherwise stated Technical data Supply Voltage 3V DC Relay Rating 2A...

Страница 17: ...Adding Devices to the XPander Interface Up to 31 wireless detectors or alarm signalling devices may be assigned to a single interface Prior to adding devices to the Interface batteries must be enabled...

Страница 18: ...s Eliminates cable problems Minimises disruption Enables rapid retrofit Modern styling Loop powered interface 915MHz Wireless addressing Radio base with wireless circuitry and battery compartment Auto...

Отзывы: