Veterinary Anesthesia WorkStation  

Operating Manual

 

 
 

 

 

Содержание AWS Anesthesia WorkStation

Страница 1: ...Veterinary Anesthesia WorkStation Operating Manual ...

Страница 2: ... or property including the equipment itself resulting from operation not in accordance with the authorized maintenance instructions unauthorized repair or modification of the equipment or accessories or from the use of components or accessories that have either been damaged or not authorized for use with this equipment by Hallowell EMC WARNINGS AND CAUTIONS Personnel operating the workstation must...

Страница 3: ...d warranty period not reported by the end user to HEMC prior to the expiration of the warranty period as defined 4 Products which have had the serial number removed or made illegible 5 Damage resulting from use of non HEMC approved accessories 6 All plastic surfaces and all other externally exposed parts that are scratched or damaged due to normal customer use 7 Products operated outside published...

Страница 4: ...y All WorkStations include and are shipped with the following Hallowell EMC Model AWS AWS accessory kit PN 000A2777 Containing 1 PN 000A3401 AWS Breathing System Assembly 24 that includes a PN 152A1261 Endotraceal Tube Adapter 2 5mm w side port b PN 220A3264B Wye AWS c PN 201A3364 Tube Clear AWS BS 10mm x 24 d PN 152A1265 Endotraceal Tube Adapter 8 5mm two 2 PN 200A2692A Valve Disc AWS two 3 PN 15...

Страница 5: ... 10mm breathing system tubes to and from the patient wye In the rear 5 SUPPLY GAS 6 SCAVENGING PORT 7 Electrical power The supply gas connection in the rear is a standard male DISS O2 connector The scavenging port will accept either the 19mm scavenger tubing or a 15mm ET adapter The electrical power inlet is the standard IEC320 connector The power supply in the AWS is a universal supply that will ...

Страница 6: ...m is leak free confirming that with no fresh gas flow FGF the ventilator puck returns to the same position at the top for several cycles If the AWS does not perform as described above DO NOT use the unit Resolve the discrepancy or remove the unit for service Warm Up Period The breathing system chamber inside the hinged cover is heated to help keep the humidity of breathing gases at saturation near...

Страница 7: ...nuing the BPM display changes to a count down at or below 5 BPM As the countdown progresses the BPM readout switches back to read the current BPM setting for two seconds at each multiple of 10 seconds and sounds a small beep This gives a visual and auditory indication that the cycle is proceeding even with long cycles Cleaning and Maintenance Use no alcohol on or near any plastic parts Clean only ...

Страница 8: ...ent tubes are also available HEMC Part 240A3267 In the event that shipping the AWS is necessary be sure to REMOVE all CO2 absorbent and seal the AWS in a plastic bag Double boxing the unit with plenty of packing material is requested RETURNING FOR SERVICE If the WorkStation has a problem which cannot be resolved using the trouble shooting procedures please call your dealer or Hallowell EMC immedia...

Страница 9: ...as Pressure 40 65 psig 275 448 kPa Rate Linear 2 80 bpm Volume 10 turn metering valve Adjustable Pressure Limit Linearly Adjustable 10 30 cm H2O Power On Front Panel mounted green LED Standby Mode Front Panel mounted yellow LED Alarm Visual Front Panel mounted yellow LED Alarm Audio Internal audio transducer PHYSICAL Unit Weight 16 lbs 7 3 kg Dimensions 9 W x 10 D x14 5 H 228mm W x 254mm D x 368mm...