background image

 

 

SC-3H 

 

RS-232 

Connect RS-232 out to the controlled device such as a projector using the appropriate 

RS-232 cable. In “slave mode” you can use the serial port to control the SC-3H, Please 

refer to Section 5.0 for more details. 

 

AUX-CTRL 

Connect to a Optional SW3-UI (or SW3-UI-VOL) keypad via CATx cabling. 

 

4.3 Factory Default 

Hold the ‘POWER’ and ‘INPUT’ buttons for more than 4 seconds to reset the unit to the 

‘FACTORY DEFAULT’ state. Factory default can also be set via PC GUI

 

 

4.4 Power Connection 

A universal 5 Volt DC power supply is provided. 

4.5 L/R IN and L/R OUT Connections 

 

 NOTE     

The L/R IN connection expects a line level signal (maximum of ~0.9 vDC). 

If you need an external preamp for low-level microphones, the Hall Research Model 

HR-101-S

 

may work for your needs. In most classroom installations, the wireless microphone present 

may have a line-level output. 
Use the following diagram for connection of external preamp (such as wireless microphone 

receiver) to the system. 
Ground referenced means that the external preamp has a connection to ground (the AC cord 

has a ground prong). 
If the preamp does not provide a balanced (differential) output, you should not tie the return of 

your source to the ground of the SC-3H. Doing so would create a ground loop that will most 

likely cause audio hum.  
If you are sure that your external preamp is floating (its AC cord has no ground prong), then it 

may be advisable to connect the negative input signal to ground at the SC-3H. 

TIP, RING and SLEEVE refer to the 

L/R IN and L/R OUT 3.5mm connectors

 

 

Figure 5 –L/R IN and L/R OUT Wiring Diagram

 

Содержание SC-3H

Страница 1: ...User s Manual SC 3H MULTI FORMAT PRESENTATION SWITCHER RS 232 CONTROLLER UMA1256 Rev 2 Copyright 2017 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Phone 1 714 641 6607...

Страница 2: ...Any other trademarks mentioned in this manual are acknowledged as the property of the trademark owners FCC RADIO FREQUENCY INTERFERENCE STATEMENT This equipment can radiate radio frequency energy and...

Страница 3: ...isplay and when the SC 3H is turned on it will send the on command to the display and upon turning the device off an off command will be issued The power commands can also function automatically In Au...

Страница 4: ...l command EDID management Supports VGA HDMI MHL on HDMI 1 and DVI Locking power supply input connector Compact Rugged Reliable and Economical 2 1 Package Contents Qty 1 SC 3H Qty 1 5V DC Universal DC...

Страница 5: ...OFF commands for external devices the unit will send those commands as it turns on or off To enter or exit Auto Power Command Mode press and hold the button for 7 seconds POWER AUTO LED This LED show...

Страница 6: ...to a compatible video source VGA HD IN Connect the VGA connector to a compatible video source L R IN Connect the 3 5mm jack to compatible line level audio source This signal is only available when us...

Страница 7: ...w level microphones the Hall Research Model HR 101 S may work for your needs In most classroom installations the wireless microphone present may have a line level output Use the following diagram for...

Страница 8: ...hown as CR in table below Invalid input spaces and line feed characters 0x0A are ignored RS 232 communication at the rear connector is configurable factory default is 9600 bps 8 Bit No Parity 1 Stop b...

Страница 9: ...Set Parity to ODD XT XT CR Transmit from RS 232 OUT with specific baud and parity Terminated with 0x17 0x0D SPx SPx CR Controls the Serial Data Pass Thru Status SP CR Query current Serial Pass Thru Se...

Страница 10: ...ensing different parameters of the currently selected input source Source Video 5V 5V from source detected will cause the ON string to be sent out 5V from source lost for more than the programmed OFF...

Страница 11: ...If you still are not able to get the system working properly contact Hall Research support preferably via email or via www hallresearch com with a detailed description of the issue and the troubleshoo...

Страница 12: ...1200 2400 4800 9600 19200 38400 57600 or 115200 USB 1 Mini B General Power Supply 100 VAC to 240 VAC 47 63 Hz External 5 VDC Temp humidity Storage 40 to 158 F 40 to 70 C 10 to 90 non condensing Operat...

Страница 13: ...SC 3H 13...

Страница 14: ......

Страница 15: ......

Страница 16: ...ght 2017 Hall Research Inc All rights reserved Toll free in the U S 800 959 6439 Email support hallresearch com Hall Research 1163 Warner Ave Tustin CA 92780 www hallresearch com CUSTOMER SUPPORT INFO...

Отзывы: