6.0 Network Settings
As shipped from the factory (or after restoring factory defaults), the HSM-44-BX
IP address is set for static IP address of 192.168.1.1. To change the IP or to
switch to DHCP, you can use either RS-232 or Telnet.
For example, to use the RS-232 port to change the IP address do the following:
•
Connect a PC with Terminal-Emulator software to the RS-232 port
•
DHCPn command can be used to change DHCP setting
•
Please see the next section with further information on commands
7.0 Serial & Telnet Commands
Telnet port is
6324
, RS-232 port settings are:
Baud rate: 115200, Parity: None, Stop: 1-bit
•
Commands are in ASCII format.
•
Commands are case sensitive.
•
Use a single <CR> character to terminate each command.
•
Responses from the Matrix are terminated with <CR><LF>.
•
Other than Power command (PW1), the matrix must be powered on.
•
Unknown commands respond with “INVALID COMMAND”<CR><LF>.
•
After plugging power to the matrix, you must wait ~45 seconds for it to fully
boot up before sending any commands.
•
Command characters should be sent continuously without pauses. If you
pause for more than 5 seconds, the command will not execute.
•
When the front panel buttons are used, some serial commands will be sent
out the RS-232 port.
Command
Description
Response
CVn,m
n= Output [1-4]
m= Input [1-4] or
m=x to blank Output
(x must be lower case)
Connect Video
output
n
to input
m
CVn,m
CV*,m
m= Input [1-4]
m=x to blank Output
(x must be lower case)
Connect all Outputs to
Input
m
CV1,m
CV2,m
:
CV4,m