Hall Research Technologies HR-722A Скачать руководство пользователя страница 6

 

 

Model 722A 

How to setup the HR-722A 

Notes:  

 

All units transmit at 1310 nm wavelength over single 
mode or multimode fiber. ST connectors are 
provided. 

 

Loss Budget and Maximum Transmission Distance: 

 

Wavelength

 

Loss Budget (in 
dB)

 

Distance* (in 
km)

 

1310 MM 

0-15 

0.75 

1310 SM 

0-15 

35 

* Distance specifications are only approximate and are not guaranteed. 
Operating loss budget must not be exceeded

 

 
The HR-722 System is ready for immediate use. There are 
LED indicators on the units for monitoring purposes. The 
following instructions describe the typical installation 
procedure and the function of the LED indicators. 

 

1.

 

Connect the video source to the video input HD-15F 
connector on the transmitter unit. 

2.

 

Connect the video output on the receiver unit to the 
HD-15F connector 

3.

 

Connect the fiber optic cable between the two units 

4.

 

Connect the audio input signals to 
the transmitter stereo jack and the 
audio output to the receiver stereo 
jack. 

5.

 

Apply power to both units. Refer to 

Figure 1. 

6.

 

When power is applied, the green POWER LED will 
light, indicating the presence of operating power.  

7.

 

The system should now be operational. 

 

Содержание HR-722A

Страница 1: ...tter Unit with Power supply 1 Receiver Unit with Power supply P P PC C C V V Vi i id d de e eo o o A A Au u ud d di i io o o T T Tr r ra a an n ns s sm m mi i is s ss s si i io o on n n S S Sy y ys s...

Страница 2: ......

Страница 3: ...ansmission System over Single Fiber Optic Cable 1 Table of Contents TABLE OF CONTENTS 1 DESCRIPTION 2 FEATURES 3 HOW TO SETUP THE HR 722A 4 FEDERAL COMMUNICATIONS COMMISSION STATEMENT 7 WARRANTY 8 LIM...

Страница 4: ...reduces installation time particularly since only 1 fiber is needed Fiber optic cable also has certain intrinsic benefits for installation success including resistance to electromagnetic interference...

Страница 5: ...ments equalization or de skewing during installation 5 Transmits signals over one single mode or multimode fiber optic core at 1310 nm 6 Virtually no audio video skew 7 Ideal for digital signage broad...

Страница 6: ...the units for monitoring purposes The following instructions describe the typical installation procedure and the function of the LED indicators 1 Connect the video source to the video input HD 15F co...

Страница 7: ...INKING Indicates audio detected on the transmitter unit RECEIVER Video OFF Indicates no video detected over fiber and as a result no video present on the output BLINKING GREEN Indicates either H or V...

Страница 8: ...fications Number of Audio Channels 2 unbalanced Frequency Response 0 0 5 dB 20 Hz 20 kHz Bits per Sample Sampling Rate 24 bits 54 kHz Maximum Audio Level 10 dBu SNR A Weighted 95 dB Input Impedance 24...

Страница 9: ...been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of the FCC rules Harmful interference when operated in a commercial environment Operation of this eq...

Страница 10: ...nauthorized modification Instructions must be followed in obtaining RMA number as explained below Any defective part should be returned insured and freight prepaid to Hall Research with the following...

Страница 11: ......

Страница 12: ...Made in the USA Copyright 2010 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Ph 714 641 6607 Fax 714 641 6698...

Отзывы: