93
Silencer Series Booster Pump
p/n: 029-0020-83-0
Corrective Maintenance
❑
6.9
SERVICING THE BOOSTER PUMP (ALL EXCEPT
TBP)
APS series volutes are mounted for either engine rotation (clockwise), as
viewed from the suction inlet, or opposite engine rotation (counterclockwise).
MBP series pumps are available in the engine rotation (clockwise) only.
Note the direction of flow of the impeller for proper mounting of the volute. Also
see Figure 2-6: “Pump / Engine Rotation” on page 20.
Volute (All Except TBP)
See Figure 6-8: “Booster Pump Parts Breakdown” on page 94
The volute is secured by hex screws (quantity dependent on pump model).
Replace the volute gasket whenever the volute is removed.
1.
Remove the suction manifold (if still installed).
2.
Unthread the compression fittings
and disconnect gearbox cooler
hoses from the volute. See See
Figure 6-7: “Typical Water Cooling
Lines’
3.
Remove the 7/16”-14 screws and
hardware securing the volute to the
pump head. Remove the volute
being careful not to damage the
impeller or scratch the sealing sur-
faces of the volute.
Note: A dead blow hammer could be
needed. Tap, in a crisscross pattern,
around the volute until it is separated from
the cover plate. Support the weight of the volute as it weighs approximately 45 lbs
(17 kgs).
Figure 6-7: Typical Water Cooling Lines
Содержание Silencer APS Series
Страница 6: ...Overview 6 Silencer Series Booster Pump p n 029 0020 83 0...
Страница 22: ...Introduction 22 Section 2 Introduction Hale Products Inc May 2006 Rev B...
Страница 32: ...Accessories Options 32 Section 2a Accessories Hale Products Inc May 2006 Rev B...
Страница 66: ...Preventive Maintenance 66 Silencer Series Booster Pump p n 029 0020 83 0...
Страница 124: ...Installation 124 Basic Installation Hale Products Inc August 06 Rev B...
Страница 143: ...143 Appendix F Cavitation Hale Products Inc Nov 2005 Rev A Cavitation...
Страница 144: ...Cavitation 144 Appendix F Cavitation Hale Products Inc Nov 2005 Rev A...