![Haldex EB Plus Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/haldex/eb-plus/eb-plus_operators-manual_3311308010.webp)
DTC DISPLAYED
EPRV 22 HOLD AND DUMP SOLENOID GROUP
EPRV 22 HOLD SC
Modulator 22 hold solenoid short circuit
EPRV 22 DUMP SC
Modulator 22 dump solenoid short circuit
EPRV 22 HOLD OC
Modulator 22 hold solenoid open circuit
EPRV 22 DUMP OC
Modulator 22 dump solenoid open circuit
EPRV 22 HOLD SC DRIVE
Modulator 22 hold solenoid short circuit permanently energised
EPRV 22 DUMP SC DRIVE
Modulator 22 dump solenoid short circuit permanently energised
EPRV 22 HOLD UNSPEC
Modulator 22 hold solenoid control circuit fault
EPRV 22 DUMP UNSPEC
Modulator 22 dump solenoid control circuit fault
DEMAND PRESSURE TRANSDUCER GROUP
DEMAND SC
Service line pressure transducer short circuit
DEMAND OC
Service line pressure transducer open circuit
DELIVERY PRESSURE TRANSDUCER GROUP
EPRV 21 DEL SC
Modulator 21 delivery pressure transducer short circuit
EPRV 21 DEL OC
Modulator 21 delivery pressure transducer open circuit
EPRV 22 DEL SC
Modulator 22 delivery pressure transducer short circuit
EPRV 22 DEL OC
Modulator 22 delivery pressure transducer open circuit
ONE WHEEL WITH SLOW RECOVERY GROUP
EPRV 21 SLOW REC
Slow recovery of one wheel of modulator 21
EPRV 22 SLOW REC
Slow recovery of one wheel of modulator 22
Possible causes:
Slow brake release, foundation brake mechanical faults, dry
bearings, broken spring, restricted piping
Check for kinks and blockages etc. Incorrect piping, Wiring.
Modulator fault. Sensor wiring crossed across an axle.
RESERVOIR PRESSURE TRANSDUCER GROUP
RESR SC
Reservoir pressure transducer short circuit
RESR OC
Reservoir pressure transducer open circuit
SUSPENSION PRESSURE TRANSDUCER GROUP
SUSP SC
Suspension pressure transducer short circuit
SUSP OC
Suspension pressure transducer open circuit
SUSP LOW
Suspension pressure values outside operating range
PRESSURE SWITCH GROUP
REV SWITCH SC
Relay emergency valve pressure switch short circuit
REV SWITCH OC
Relay emergency valve pressure switch open circuit
REV SWITCH PNEUMATIC
Relay emergency valve pressure switch pneumatic fault
REV SWITCH SIGNAL
Relay emergency valve pressure switch failed to activate
10