background image

                                                                 

                 

                   

 

Page 9 of 24 

 

V2.0 

 

 

Position Sensitivity:    None 

 

Expected Sensor Life:    5 years in non-corrosive environment. 

 

Display Unit: ppm (4 digit LCD) or mg/m

3

 

 

Memory: Up to 500 sets of data   

 

Interface: USB (Window XP/7/8 compatible) 

 

Power: Rechargeable Lithium ion battery (3.7V/1200mAh); AC charger 100~ 

240VAC to 5VDC/1A 

 

Dimension: 80 (W) 

 157 (H) 

 45 (D) mm   

 

Weight: Less than 240 grams 

 

Environmental Condition: Operating: 0 ~ 40

C, 15% ~ 90%RH; Storage: -20 ~ 50

C, 

<90%RH 

 

Standard accessories: AC charger, USB cable, CD with data download software and 

user manual 

 

Optional accessories: Digital pressure, temperature, and humidity sensor probe 

 

1.3 Sensor cross sensitivity data 

Chemicals 

Cross Sensitivity 

Ethanol

 (

C

2

H

6

O) 

45% 

Sulfur Dioxide (SO

2

12% 

Phenol (C

6

H

6

O) 

7% 

Carbon Monoxide (CO)   

1% 

Hydrogen Gas (H

2

0.1% 

Chlorine Gas(Cl

2

   

-3% 

Acetone

 (

C

3

H

6

O), Ammonia (NH

3

), CO

2

, slow

 

H

2

O vapor have no response; 

C

2

H

4

, H

2

S, NO, and NO

2

 have no data. 

Содержание HFX205

Страница 1: ...L HFX205 Handheld Formaldehyde Meter Monitor Operational Manual 7970 Cherry Avenue Suite 303 Fontana CA 92336 USA Phone 855 438 4258 toll free Fax 866 402 9190 toll free Info haltechnologies com http...

Страница 2: ...Page 2 of 24 V2 0 This Page intentionally left as blank...

Страница 3: ...eatures 8 1 2 Specifications 8 1 3 Sensor cross sensitivity data 9 II Basic Operation 10 2 1 Measuring Screen 10 2 1 1 Detailed Screen Description 11 2 2 Browsing Screen 13 2 3 Setting Screen 15 2 3 1...

Страница 4: ...e 4 of 24 V2 0 Version Table Date Version Comment May 22 2015 2 0 User Interface Redesigned February 1 2014 1 2 Window 7 8 Compatible Upgrade May 3 2012 1 1 Final Release May 18 2010 1 0 Initial Relea...

Страница 5: ...t any time without notice or obligation Published in the United States of America Copyright 2015 by Hal Technology All rights reserved No part of the contents of this manual may be reproduced transmit...

Страница 6: ...wing situations DO NOT expose to combustible explosive environments DO NOT expose to environments where rust or radioactivity are present DO NOT expose to an environment exceeding the specified limits...

Страница 7: ...on time Low power design allows long operation time Exceptional linearity and stability allow easy and very long intervals between calibration checks The external digital temperature and humidity sens...

Страница 8: ...erature and humility sensor probe options Temperature compensated reading option Live data streaming and TWA STEL measurement capabilities through USB Excess limit warning user defined Window XP 7 8 c...

Страница 9: ...Less than 240 grams Environmental Condition Operating 0 40 C 15 90 RH Storage 20 50 C 90 RH Standard accessories AC charger USB cable CD with data download software and user manual Optional accessori...

Страница 10: ...screen or item ENTER Confirm the current selection enter a parameter or save the current sampling value BACK Change the concentration unit while the unit is measuring or return from the current selec...

Страница 11: ...STOP key to stop measuring The instrument will automatically shut off after 5 minutes of inactivity unless the unit is sampling 2 1 1 Detailed Screen Description Figure 1 Annotated measure screen of t...

Страница 12: ...the alarm were turned off an X would appear next to the alarm icon Battery Status The battery indicator displays the battery s remaining charge graphically Three bars represent 100 of charge in the b...

Страница 13: ...ure sensor probe to function If no probe is installed the unit will display hPa Time Current time set by a user is displayed Date Current date set by a user is displayed By default the backlight will...

Страница 14: ...number of records e g 253 253 In Figure 2 the user is viewing record number 253 of a total 253 records Delete a Record Press the UP or DOWN key to select the record to be deleted and press the ENTER...

Страница 15: ...creen An arrow will appear as in Figure 4 Use the UP and DOWN buttons to scroll through the different settings Scroll to the desired setting and press the ENTER button to select that parameter A new s...

Страница 16: ...have made press the ENTER button When completed press the BACK button to exit the date setting screen Sample Interval The sample interval parameter can be set to either take a sample every n minutes w...

Страница 17: ...ound This options allows the user to set the keypad sound options Neither the alarm indicator nor the power up sounds will be affected by this setting To modify the button sounds option go into the so...

Страница 18: ...ast setting screen and press the ENTER button The currently selected option will have a blinking underscore beneath it and using the UP and DOWN buttons will change the option between 1 and 9 To cance...

Страница 19: ...Y values in the second column represent the response of the sensor to be calibrated The values in the third column are the calibration coefficients An example calibration procedure is described below...

Страница 20: ...N STOP button to start sampling Wait for Y value to stabilize and then press the RUN STOP button again 8 After finishing both samplings move the cursor back to the first row Press and hold the ENTER b...

Страница 21: ...c Unauthorized opening of the instrument Damage due to operation in an un specified environmental condition Abnormal operation due to instrument needing calibration Limitation of Warranty A Hal Techno...

Страница 22: ...to pay when due any portion of the purchase price or any other payment required from Buyer to Hal Technology under this contract or otherwise all warranties and remedies granted under this Section ma...

Страница 23: ...n site at buyer s facility by a Hal Technology authorized employee Buyer pays shipping costs to factory seller will pay standard return shipping costs during the warranty period Buyers may select a fa...

Страница 24: ...information to the email address below services haltechnologies com User Registration Form Company _____ Contact Person ______________ Address ______ ______ __ City ____State Province Country _____ Po...

Отзывы: