05-7182-01.fm
83
Maintenance and Servicing
5.5.3
Ejecting the brushes/pads
1. Make sure that the rotating brush unit has been raised and the machine is
stationary.
2. Select soft key
Eject brushes
using the turn-push knob and
confirm. The action window
opens. Use the turn-push knob to
confirm the start.
The procedure starts and symbols
Fig. 42-C, D
appear on the multifunction
display one after the other. Only now is the procedure complete.
3. Open the wiper, see section 5.8.1 and remove the brushes/pads.
5.5.4
Coupling the brushes/pads
:
1. Make sure that the rotating brush unit has been raised and the machine is
stationary.
2. Open the wiper and place the brushes/pads in a central position
underneath the brush head holder.
3. Select soft key
Couple brushes
using the turn-push knob and
confirm. The action window
opens. Use the turn-push knob to
confirm the start.
The procedure starts and symbols
Fig. 43-C, D
appear on the multifunction
display one after the other. Only now is the procedure complete.
4. Check whether the brushes have been coupled.
5. Close the wiper.
Fig. 42:
A
B
C
D
Fig. 43:
B
C
D
A