Foil 94
10. Error Table With Information
On Service Display
Error code in
Malfunction
Remark
the display
1.3.6.2.
Blocking protection
Jammed? Lifting element stopped by
Lifting element
limit stop before being switched off by
Side brush
micro-switch? Check coding of
1); 2)
Module 3 Code D Measure
operating current
(approx. 1.2A max. during lifting)
1.4.6.1.
Electronic circuit-breaker Jammed? Lifting element stopped by
Lifting element
limit stop before being switched off by
Squeegee
micro-switch? Check coding of
1); 2); 3); 4); 5)
Module 1 Measure operating current
(approx. 3.2A max. during lifting)