HAKO FA-430 Скачать руководство пользователя страница 2

7. PARTS LIST

HAKKO FA-430

Pre-filter

Main filter

Cap

Knob

Power switch 

Power cord, 3 wired cord but no plug

Power cord, 3 wired cord & BS plug

Power cord, 3 wired cord& European plug

Power cord, 3 wired cord & BS plug

Power cord, 3 wired cord & Australian plug

Power cord, 3 wired cord & Chinese plug

Power cord, 3 wired cord & American plug

Power cord, 3 wired cord & SI plug

Power cord, 3 wired cord & BR plug

 

1

2

3

4

5

6

A1572

A1573

B3619

B1486

B2852

B2421

B2422

B2424

B2425

B2426

B2436

B3508

B3550

B3616

Part No.

Part Name      

Specifications

Item No.

Specifications

Nothing happens when the power switch 

   is turned on.

Orange lamp keeps flashing after replacing 

    the pre-filter.

Red lamp is flashing for 5 seconds just 

   after turning the power switch on.

Red lamp keeps flashing after replacing 

   the main filter.

Red lamp lights up.

All lamp flashes at the same time.

Is the power cord disconnected ?
Connect it.
Is the main filter set properly ?
Fit the main filter properly before turning 
on the power switch again.
Is the flow control set to RESET ?
Adjust the flow suitable for working 
environment by using the flow 
selection switch.

When replacing the filter, Is the flow 
selection switch adjusted to RESET with 
the power switch on ?
Make sure that power switch is ON, 
and set the flow selection switch to 
RESET again.

When replacing the filter, Is the flow 
selection switch adjusted to RESET with 
the power switch on?
Make sure that power switch is on 
and set the flow selection switch to RESET. 
Lift the main filter more than 3 seconds.

Main filter needs to be replaced. 
Recommend replacing the main filter 
otherwise performance
will be reduced.

Main filter has exceeded its service life 
and was never replaced. It has passed 
more than 2500 hours since it is used.
Main filter must be replaced. Failure to do 
so may result in damage to the unit.
Contact your HAKKO representative 
because it is necessary to repair the 
main unit.

1

2

10

5

7

4

3

6

3

4

9

9

8

11

Option

Duct set / 

Rectangular nozzle

Duct set / 

Round nozzle

Duct

Adapter

Adapter

Rectangular nozzle 

Round nozzle 

Bench top hood 

Net

Duct

Duct band 

Duct (1) / Adapter (1)

Rectangular nozzle(1) / Net (1)

Duct (1) / Adapter (1)

Round nozzle (1) / Net (1)

φ 55 mm

For 3 inch

5 pcs.

For 3 inch (φ 75 mm)

Set of 2

C1571

C1572

B3642

B3620

B3621

B3622

B3623

B2418

B3625

B2410

B2416

10
11

Item No. Part No.

Part Name      

1

2

3
4
5
6
7
8
9

7. PARTS LIST

6. TROUBLE SHOOTING GUIDE

5. MAINTENANCE

Performing proper and periodic maintenance extends the product life. Wear of the product will 

differ depending on work environment, the quality and quantity of the solder and flux.  

Apply the following service procedure as dictated by the conditions of the usage.

How to replace the filter

The lamp status indicates appropriate time to replace the main filter and pre-filter.

    If continuing to use the main filter or pre-filter after the lamp status indicates it is time for

    replacement, it may result in reduced performance and/or subsequent damage to the unit.

A. Pre-filter

In case of replacing the pre-filter only with the red and orange lamp flashing.

B. Main filter 

*If not replacing the main filter after the lamp indicated to replace it, the red lamp 

 will flash for 5 seconds every time the power switch is turned on.

When replacing the filter, set the flow selection switch to RESET 

    without turning off the power switch.

Pre-filter lamp (orange) flashes. 

Set the flow selection switch to RESET with the power switch on. (The fan will stop.)

Open the upper cover and remove the pre-filter only. Fit the new pre-filter on top of the main filter 

so that it lies flat with no gaps, then close the upper cover.

Set the flow selection switch back to the previous position. 

The fan will start running and the unit will return to a normal operating condition.

Pre-filter : 80% of the pre-filter is clogged or it was used for 200 hours. (The orange lamp flashes.)

Pre-filter lamp (orange) and main filter lamp (red) flash.

Set the flow selection switch to RESET with the power switch on. (The fan will stop.)

Open the upper cover and then remove the pre-filter only. Fit the new pre-filter on top of the 

main filter so that it lies flat with no gaps, then close the upper cover.

Set the flow selection switch back to the previous position. 

After 5 seconds are passed, the red lamp will be turned off.

1

2

3

4

Turning on the power 

After 

5 seconds

MAIN

POWER

PRE

MAIN

POWER

PRE

After

5 seconds

MAIN

PRE

POWER

MAIN

POWER

PRE

MAIN

POWER

PRE

MAIN

POWER

PRE

MAIN

POWER

PRE

MAIN

POWER

PRE

MAIN

PRE

POWER

MAIN

POWER

PRE

1

2

3

4

Pre-filter lamp (orange) and main filter lamp (red) flash.

Set the flow selection switch to RESET with the power switch on. (The fan will stop.)

Open the upper cover and then remove both main filter and pre-filter.

Replace the filters with the new filters, fit them in the main unit and close the upper cover.

Set the flow selection switch back to the previous position. 

The fan will start running and the unit will return to a normal operating condition.

1

2

3

4

MAIN

POWER

PRE

MAIN

POWER

PRE

MAIN

POWER

PRE

Flashing
Lighting
OFF

Do not lift the main filter when replacing the pre-filter.If the main filter is lifted for more than 

3 seconds with the power switch on and the flow control set to RESET, 

the used number of the pre-filter are reset to zero.

Filter replacement timing

Main filter : When the 10th pre-filter needs replacing. (The orange and red lamp flash.)

Replacing the filter without following the procedure will disrupt the timing for filter replacement

and may cause the overuse of the filters and subsequent damage to the unit.

10 pcs.

HAKKO FA-430 counts used number of the pre-filter in order to determine the 

remaining life of the main filter. There are a few points to observe when replacing filters. 

Read “How to replace the filter” and follow the procedure. 

Replacing the filter without following the procedure may cause the overuse 

of the main filter and subsequent damage to the unit.