2. SPECIFICATIONS
4. OPERATION
4. OPERATION
1. PACKING LIST AND PART NAMES
1
1
1
Main filter (inside main unit) 1
10pcs.
FUME EXTRACTION
3.WARNINGS, CAUTIONS, NOTES AND EXAMPLES
2012.3
MA01866XZ120301
Copyright © 2012 HAKKO Corporation. All Rights Reserved.
●
Duct set (not included)
1. Open the upper cover and then remove the
plastic bag from the main filter.
2. Put the main filter on the main unit. Set the
filter with the arrow pointing down
(as shown in the illustration).
3. Fit the pre-filter on top of the main filter.
(orange side facing up )
●
Attach the duct
2. Fit the net on the nozzle. (Figure.2)
3. Insert the duct into the open port.
If using one duct, ensure the cap is in place
on the unused port.
When using two ducts, please store the cap
inside the main unit next to the main filter as
shown in Figure 3 (right).
B. How to attach bench top hood.
A. How to attach duct set
(Fig.1)
Duct set (Duct / Adapter / Rectangular nozzle or
Round nozzle / Net)
Net
*When using the duct for B2410
(φ75 mm
)
, set the 3 inch
adapter to the main unit.
Rectangular nozzle
*1 When using 2 ducts
*2 It is an initial value of collection efficiency based on counting method for airborne dust collected
by a single plate of filter (unfolded).
●
HAKKO FA-430
When using a bench top hood,
the following parts are required:
●
3 inch adapter
●
3 inch duct (φ75 )
●
Duct band
*Refer to “7. PARTS LIST” for part numbers.
*The standard duct for the HAKKO FA-430
can not be used to connect a bench top hood.
Do not absorb combustible, explosive or corrosive gas.
Store the fume extraction unit in a dry place.
Do not block the exhaust vent of the fume extraction unit.
Use only genuine HAKKO replacement parts.
Turn the power off when not in use, or left unattended.
Turn the power off when changing parts or storing the HAKKO FA-430.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the appliance.
●
●
●
●
●
●
●
●
●
To prevent accidents or damage to the HAKKO FA-430, be sure to observe the followings:
●
●
●
●
Do not operate the fume extraction without the filter; otherwise it may cause the unit to malfunction.
Hold the plug when inserting or removing the cord in/from the outlet.
Do not allow the HAKKO FA-430 to become wet, or use it with wet hands.
While using the HAKKO FA-430, don’t do anything which may cause bodily harm or physical damage.
Thank you for purchasing the HAKKO FA-430 Fume Extraction system.
Please read this manual before operating the HAKKO FA-430.
Keep this manual readily accessible for reference.
Please check to make sure that all items
listed below are included in the package.
This product includes such features as electrically conductive plastic parts and grounding of the unit
as measures to protect the device to be soldered from the effects of static electricity. Be sure to observe
the following instructions:
1. The plastic parts are not insulators, they are conductors. When making repairs or replacing
parts, take sufficient care not to expose live electrical parts or damage insulation materials.
2. Be sure to ground the unit during use.
4. Close the upper cover
Be sure the pre-filter lies flat and completely
covers the top of the main filter with no gaps.
1. Refer to Figure 1(right), and attach the
nozzle and adapter to the duct.
Insert the nozzle and adapter until it stops,
turn the nozzle clockwise. Make sure the
nozzle and adapter are firmly attached.
Twist the nozzle tight enough to avoid
coming off.
Instruction Manual
HAKKO FA-430 Fume extraction system
Power cord
Cap (inside main unit)
Pre-filter
Instruction manual 1
Power Consumption
Suction Capacity *1
Filtering Efficiency *2
Duct diameter
Dimensions
Weight (w/o cord)
*Specifications and design are subject to
change without notice.
or
Duct
Adapter
Round nozzle
●
Option
Bench top hood
3 inch adapter
WARNING
CAUTION
(Fig.3)
(Fig.2)
Cap
120W
High
Medium
Low
4.7m³/min 3.7m³/min 2.8m³/min
High: 99.96% / Medium·Low:
99.97%
φ55 mm
330(W) x 366(H) x 343(D) mm
7.5 kg
風扇組合
插頭
1 Insert the nozzle
until it stops.
Turn the nozzle clockwise.
2
Be sure the duct is
facing in the
proper direction
during assembly.
or
Instruction manual in the language of Japanese, English, Chinse, French, German and Korean
can be downloaded from the HAKKO Document Portal.
(Please note that some languages may not be available depending on the product.)
HAKKO FA-430
Fume extraction
Cap
Main filter
Pre-filter
Power cord
●
Set the filter
Pre-filter
(orange side
facing up)
Main filter
(facing the
arrow
downward)
●
Fume extraction unit
1. Connect the power cord to the power
receptacle on the right of the unit.
2. Plug the power cord into a ground wall socket.
3. Turn the power switch on. Power lamp will light up.
4. Adjust the flow suitable for working environment
by using flow selection switch.
5. Adjust the angle of the duct and nozzle as needed
for optimal performance.
Close the cover before turning the power switch on.
●
Do not block the open port on purpose.
●
When the fan is running, do not open the
upper cover.
●
Turn the power off when not in use.
Failure to do so may result in shorter filter life.
●
If it passes more than 2500 hours or one year
since the HAKKO FA-430 is used, replace the
main filter with new one at once.
If using the main filter over replacement
timing, doing so may result in damage to
the main unit.
Replacement Indicator Lamp
(Pre-filter/ orange)
Low
High
Medium
Replacement Indicator Lamp
(Main filter/ red)
Power lamp (Green)
Flow selection
switch
Filter life reset
Power switch
3 inch
adapter
3 inch
duct
Duct band
Exhaust vent