HAKO FA-430 Скачать руководство пользователя страница 1

®

2. SPECIFICATIONS

4. OPERATION

4. OPERATION

 1. PACKING LIST AND PART NAMES

 

1

 

 

1

Main filter (inside main unit)                                            1

                                 

10pcs.

FUME EXTRACTION

3.WARNINGS, CAUTIONS, NOTES AND EXAMPLES

2012.3

MA01866XZ120301

Copyright © 2012 HAKKO Corporation. All Rights Reserved.

Duct set (not included)

1. Open the upper cover and then remove the 

    plastic bag from the main filter.

2. Put the main filter on the main unit. Set the 

    filter with the arrow pointing down

    (as shown in the illustration).

3. Fit the pre-filter on top of the main filter. 

   (orange side facing up )

Attach the duct 

2. Fit the net on the nozzle. (Figure.2)

3. Insert the duct into the open port. 

    If using one duct, ensure the cap is in place 

    on the unused port.

    When using two ducts, please store the cap 

    inside the main unit next to the main filter as

    shown in Figure 3 (right).

   

B. How to attach bench top hood.

A. How to attach duct set

(Fig.1)

Duct set (Duct / Adapter / Rectangular nozzle or 

               Round nozzle / Net)

Net

*When using the duct for B2410

  (φ75 mm

, set the 3 inch 

  adapter to the main unit.

Rectangular nozzle

*1 When using 2 ducts

*2 It is an initial value of collection efficiency based on counting method for airborne dust collected 

    by a single plate of filter (unfolded).

HAKKO FA-430

When using a bench top hood, 

the following parts are required:

3 inch adapter 

3 inch duct (φ75 )

Duct band 

*Refer to “7. PARTS LIST” for part numbers.

*The standard duct for the HAKKO FA-430 

  can not be used to connect a bench top hood.

Do not absorb combustible, explosive or corrosive gas.

Store the fume extraction unit in a dry place.

Do not block the exhaust vent of the fume extraction unit.

Use only genuine HAKKO replacement parts. 

Turn the power off when not in use, or left unattended.

Turn the power off when changing parts or storing the HAKKO FA-430.

This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible 

for their safety.

Children should be supervised to ensure that they do not play with the appliance.







To prevent accidents or damage to the HAKKO FA-430, be sure to observe the followings:




Do not operate the fume extraction without the filter; otherwise it may cause the unit to malfunction. 

Hold the plug when inserting or removing the cord in/from the outlet.

Do not allow the HAKKO FA-430 to become wet, or use it with wet hands.

While using the HAKKO FA-430, don’t do anything which may cause bodily harm or physical damage.

Thank you for purchasing the HAKKO FA-430 Fume Extraction system.

Please read this manual before operating the HAKKO FA-430.

Keep this manual readily accessible for reference.

Please check to make sure that all items 

listed below are included in the package.

This product includes such features as electrically conductive plastic parts and grounding of the unit 

as measures to protect the device to be soldered from the effects of static electricity. Be sure to observe 

the following instructions:

1. The plastic parts are not insulators, they are conductors. When making repairs or replacing

parts, take sufficient care not to expose live electrical parts or damage insulation materials.

2. Be sure to ground the unit during use.

4. Close the upper cover

Be sure the pre-filter lies flat and completely 

covers the top of the main filter with no gaps.

1. Refer to Figure 1(right), and attach the 

    nozzle and adapter to the duct.

    Insert the nozzle and adapter until it stops, 

    turn the nozzle clockwise. Make sure the 

    nozzle and adapter are firmly attached.

     

Twist the nozzle tight enough to avoid 

coming off.

Instruction Manual

HAKKO FA-430 Fume extraction system

Power cord 

Cap (inside main unit)

Pre-filter

Instruction manual                                                           1 

Power Consumption

Suction Capacity *1

Filtering Efficiency *2  

Duct diameter

Dimensions

Weight (w/o cord)

 *Specifications and design are subject to 

  change without notice.

or

Duct

Adapter

Round nozzle

Option

Bench top hood

3 inch adapter

WARNING

CAUTION

(Fig.3)

(Fig.2)

Cap

120W

High    

  

Medium    

   

Low

4.7m³/min   3.7m³/min      2.8m³/min

High: 99.96% / Medium·Low:

 

99.97%

φ55 mm

330(W) x 366(H) x 343(D) mm

7.5 kg

風扇組合

插頭

1 Insert the nozzle 

until it stops.

Turn the nozzle clockwise.

2

Be sure the duct is 

facing in the 

proper direction 

during assembly.

or

Instruction manual in the language of Japanese, English, Chinse, French, German and Korean

can be downloaded from the HAKKO Document Portal.

(Please note that some languages may not be available depending on the product.) 

HAKKO FA-430

Fume extraction

Cap

Main filter

Pre-filter

Power cord

Set the filter

Pre-filter

(orange side

 facing up)

Main filter

(facing the

 arrow 

 downward)

Fume extraction unit

1. Connect the power cord to the power 

    receptacle on the right of the unit.

2. Plug the power cord into a ground wall socket.

3. Turn the power switch on. Power lamp will light up.

4. Adjust the flow suitable for working environment

    by using flow selection switch.

5. Adjust the angle of the duct and nozzle as needed 

    for optimal performance.

Close the cover before turning the power switch on.

Do not block the open port on purpose.

When the fan is running, do not open the 

   upper cover.

Turn the power off when not in use. 

   Failure to do so may result in shorter filter life.

If it passes more than 2500 hours or one year 

   since the HAKKO FA-430 is used, replace the 

   main filter with new one at once.

   If using the main filter over replacement 

   timing, doing so may result in damage to

   the main unit.  

Replacement Indicator Lamp 

(Pre-filter/ orange)

Low

High

Medium

Replacement Indicator Lamp 

(Main filter/ red)

Power lamp (Green)

Flow selection 

switch

Filter life reset

Power switch

3 inch

adapter

3 inch

duct

Duct band

Exhaust vent

Отзывы: