background image

22-2

 

22.  SHARP PLC

JW100/70H COM Port, JW20 COM Port: System Memory Setting

The settings for communications with the V7 series should be made at the system memory as shown 
below.

JW-70CU/100CU, JW70CUH/100CUH, JW22CU

JW-32CUH/33CUH

- Communication port 1

- Communication port 2

Available Memory

The available memory setting range varies depending on the PLC model.  Be sure to set within the 
range available with the PLC to be used.  Use [TYPE] when assigning the indirect memory for macro 
programs.

*1

File Register Setting on V-SFT Editor
Enter “file number” + “: (colon)” + “address” in order.

System Memory

Setting

Contents

#236

30H

Stop bit: 2 bits, parity: even, baud rate: 19200

#237

01H

Port

System Memory

Setting

Contents

#234

30H

Stop bit: 2 bits, parity: even, baud rate: 19200

#235

01H

Port

System Memory

Setting

Contents

#236

30H

Stop bit: 2 bits, parity: even, baud rate: 19200

#237

01H

Port

Memory

 TYPE

Remarks

X9XXX

(register)

0

XXXXX

(relay)

1

 for word device

EXXXX

(self diagnosis)

2

bXXXX

(timer, counter/current value)

3

Fn

(file register)

7

*1

Example:   F1 : 00002

Address
Colon
File number

Содержание V Series

Страница 1: ...V Series...

Страница 2: ...Record of Revisions Reference numbers are shown at the bottom left corner on the back cover of each manual Printing Date Reference No Revised Contents February 2004 2200NE0 First edition...

Страница 3: ...CC LINK are contained 1028NE Specifications for PROFIBUS Communication Unit Instructions for PROFIBUS are contained 1036NE Connection with AB Control Logix The connection communication parameters and...

Страница 4: ...when you set up the unit connect cables or perform maintenance and inspection Otherwise electrical shock or damage may occur Never touch any terminals while the power is on Otherwise electric shock ma...

Страница 5: ...r incorrect cable connection could cause fire malfunction or damage to the unit Be sure to establish a ground of MONITOUCH Ground FG terminal which must be used for the unit Otherwise electric shock o...

Страница 6: ...OUCH surface Use alcohol or benzine commercially available If a data receive error occurs when MONITOUCH and the counterpart PLC temperature controller etc are started at the same time read the manual...

Страница 7: ...le Memory 3 2 Wiring 3 2 4 Baldor PLC Available PLCs 4 1 Communication Setting 4 1 Available Memory 4 1 Wiring 4 2 5 DELTA PLC Available PLCs 5 1 Communication Setting 5 1 Available Memory 5 1 Wiring...

Страница 8: ...2 Wiring 14 4 15 Matsushita Electric Works PLC Available PLCs 15 1 Communication Setting 15 1 MEWNET Link Unit Switch Setting 15 2 Available Memory 15 2 Wiring 15 3 16 MITSUBISHI ELECTRIC PLC Availabl...

Страница 9: ...ilable PLCs 24 1 Communication Setting 24 1 Available Memory 24 4 Wiring 24 7 25 TAIAN PLC Available PLCs 25 1 Communication Setting 25 1 Available Memory 25 1 Wiring 25 2 26 Telemecanique PLC Availab...

Страница 10: ...ink 2 Multi link 2 App2 1 Wiring App2 2 V SFT Setting App2 6 Communication Error App2 7 Appendix 3 n 1 Connection Multi link Multi link App3 1 Wiring App3 2 V SFT Setting App3 5 Appendix 4 1 n Connect...

Страница 11: ...7 V Link V Link App7 1 Wiring App7 2 V SFT Setting App7 4 Protocol App7 5 NAK Error Codes App7 9 1 byte Character Code List App7 10 Connection Compatibility List V712 V710 V708 V706 DU 01 List 1 V706...

Страница 12: ...ications according to the protocol of the PLC Consequently it is not necessary to have the dedicated communication program on the PLC slave station The V7 series reads the PLC memory for screen displa...

Страница 13: ...eries is connected to multiple PLCs Maximum connectable PLCs 31 Notes on Connection For more information refer to Appendix 4 1 n Connection Multi drop PLC1 PLC2 PLC3 PLCn CN1 Maximum length V7 series...

Страница 14: ...e one for 1 1 connection Use the RS 485 2 wire connection between stations of the V7 series Please use Hakko Electronics multi link 2 master cable V6 MLT for connection between the master station Loca...

Страница 15: ...els refer to Connection Compatibility List at the back of this manual RS 422 connection between the V7 series PLC must be in 2 wire connection The V7 and V6 series can be used together Notes on Connec...

Страница 16: ...gnal ground 8 Not used 9 5 V Use prohibited 10 0 V Use prohibited 11 Not used 12 SD RS 422 send data 13 SD RS 422 send data 14 RS RS 422 RS send data 15 Not used 16 Not used 17 RS RS 422 RS send data...

Страница 17: ...de of the V706 The switch is factory set to RS 422 When RS 422 is selected the slide switch is in the lower position To select RS 232C slide the switch to the upper position MJ2 Pin No Signal Name Con...

Страница 18: ...cation cable refer to the CN1 pin arrangement With V6 TMP Refer to the PLC wiring diagram and the MJ2 pin arrangement Example Connecting to MITSUBISHI A1SJ71UC24 R2 PLC 1 2 3 4 5 7 RD SD RS CS DR SG C...

Страница 19: ...ground Connect the shielded cable to the metal shell of modular jack 2 Twisted pairs of 0 3 mm sq or above are recommended If noise disturbs communications use twisted pairs between SD SG and RD SG DA...

Страница 20: ...option unit DU 01 must be installed The DIP switch on the side or back of V7 series units is used to set the terminating resistors For more information refer to the description of the DIP switch setti...

Страница 21: ...types available Depending on the selected type the setting items in the Comm Parameter dialog or those for the memory vary Select 1 1 for 1 1 connection Local No Set the port number of the PLC Trans...

Страница 22: ...t Process LSB MSB MSB LSB When processing characters choose either option for arranging 1st 2nd bytes in one word Code DEC BCD Choose the code for entering numerical data For some numerical data such...

Страница 23: ...tus command Address Name Contents n RCVDAT Sub command data n 1 SCRN_COM Screen status command n 2 SCRN_No Screen number command BZ0 0 1 leading edge Free To forcibly change the bits for free area the...

Страница 24: ...en command number 5 remains the same as before in the memory address D2 in the read area for the screen number command In such a case it is possible to forcibly switch the screen to the screen number...

Страница 25: ...ata in read area n n 1 SCRN_COM Screen status n 2 SCRN_No Displayed screen number BZ0 Free BZ1 System reserved setting 0 Calendar setting System reserved setting 0 15 14 13 12 11 10 09 08 07 06 05 04...

Страница 26: ...t PLC Type PLC Unit Port Connection PLC 5 PLC 5 1785 KE RS 232C Wiring Diagram 1 1770 KF2 RS 232C Wiring Diagram 2 RS 422 Wiring Diagram 6 SLC500 SLC 5 03 and later CPU processor module RS 232C channe...

Страница 27: ...supported Transmission code Data length 8 8 Stop bit 1 1 Protocol Full duplex fixed Error check BCC fixed Reponse NO fixed Item Setting on PLC V7 Comm Parameter Setting Baud rate 9600 bps 9600 bps Po...

Страница 28: ...current value 4 C PRE counter set value 5 I input 6 O output 7 S status 8 T timer control 9 C counter control 10 R control 11 R LEN control data length 12 R POS control data position 13 D BCD 14 A ASC...

Страница 29: ...using SW6 Asynchronous link communication speed Adjust to the settings of the V7 series No Setting Contents 1 ON Data highway 57 6 kbps 2 ON 3 ON Link communication speed 19 2 kbps 4 ON 5 ON 6 ON Loca...

Страница 30: ...ssion link Switch Setting Contents 1 2 OFF ON RS 232C ON OFF RS 422 Driver DF1 Full Duplex Baud 19200 Parity EVEN Control Line No Handshaking Error Detection BCC Embedded Responses Auto Detect ACK Tim...

Страница 31: ...Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TXD RXD PLC RTS CTS 2 3 4 5 6 DSR SG 7...

Страница 32: ...1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RXD PLC TXD DTR 2 3 4 5 COM 6 7 8 DSR RTS CTS 1 2 3 4 5 7 SD RD RS C...

Страница 33: ...06 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC RTS CTS DSR DCD 4 5 6 8 14 TDA RDA 16 18 20 25 R...

Страница 34: ...13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 9 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the mod...

Страница 35: ...2 10 2 Allen Bradley PLC Please use this page freely...

Страница 36: ...unit RS 232C Wiring Diagram 3 D4 430 RS 232C Wiring Diagram 1 RS 422 Wiring Diagram 5 D4 440 Port 1 on a CPU unit D4 450 Port 0 on a CPU unit RS 232C Wiring Diagram 4 Direct LOGIC K Sequence Port 3 on...

Страница 37: ...ring Diagram 1 Memory TYPE Remarks V data register 0 X input relay 1 Y output relay 2 C internal relay 3 S stage 4 GX global inputs 5 GY global outputs 6 T timer contact 7 CT counter contact 8 SD RD P...

Страница 38: ...1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TXD RXD PLC RTS CTS 0V 2 3 4 5 7 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 U...

Страница 39: ...metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RXD RXD PLC CTS1 TXD1 TXD1 RTS1 RTS1 CTS1 9 10 11 14 16 18 19 23 SG 7 1 7 12 13 24 25 SG SD SD...

Страница 40: ...D 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male In case SU 6M it is possible to use terminal blocks D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used a...

Страница 41: ...3 6 3 Automationdirect PLC Please use this page freely...

Страница 42: ...set within the range available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type Unit Port Connection Mint NextMove Comms Data Array RS 232C Wirin...

Страница 43: ...TR SG 2 3 4 5 DSR RTS CTS 6 7 8 1 2 3 SD RD SHELL 8 7 1 7 SG 5 Use shielded twist pair cables D sub 9 pin female D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The...

Страница 44: ...ith the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Unit Port Connection DVP series DVP series RS 485 Communication port RS 485 Wiring Diagram 1 I...

Страница 45: ...iring Diagram 1 PLC 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell...

Страница 46: ...ograms Select PLC Type PLC Unit Port Connection Power Mate Power Mate Model H D Port on the CPU unit JD14 RS 422 Wiring Diagram 2 Power Mate i Model H D JD42 RS 232C Wiring Diagram 1 JD40 RS 422 Wirin...

Страница 47: ...e metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No Half pitch 20 pin PLC JD14 RDB RDA SDB 1 3 2 4 11 SDA 0V RDB RDA 1 2 R JD15 R 120 1 2W 1 7 12...

Страница 48: ...0V 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular ja...

Страница 49: ...6 4 6 FANUC PLC Please use this page freely...

Страница 50: ...macro programs Select PLC Type PLC Unit Port Connection FACON FB series FACON FB series FB DTBR RS 232 Wiring Diagram 1 Wiring Diagram 2 RS 422 Wiring Diagram 3 Item Setting on PLC V7 Comm Parameter...

Страница 51: ...Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RTS1 RXD1 CTS1 SG 2 4 5 7 TXD1 3 PLC 1...

Страница 52: ...7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2...

Страница 53: ...7 4 7 FATEK AUTOMATION PLC Please use this page freely...

Страница 54: ...F70S NC1L RS2 RS 232C Wiring Diagram 1 NC1L RS4 RS 485 Wiring Diagram 3 F80H F120H F120S F140S F15 S FFU120B RS 232C Wiring Diagram 1 FFK120A RS 485 Wiring Diagram 3 SPB N Mode FLEX PC series 1 NS T N...

Страница 55: ...ting SW 0 for both 10 1 RS 485 terminating resistance ON Character switches Item Setting on PLC V7 Comm Parameter Setting Baud rate 19200 bps 19200 bps Port 0 0 Parity Even Even Transmission code Data...

Страница 56: ...s processed as described below For input Upper 8 bits are 0 For output Lower 8 bits are written 3 To set up the file memory on the V SFT editor enter file number colon address in order Notes on V4 or...

Страница 57: ...Y 5 WY as word device R file register W 6 TN timer current value TN 7 CN counter current value CN 8 T timer contact T 9 C counter contact C 10 WS step relay Not provided 11 Memory TYPE Remarks D data...

Страница 58: ...Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RD SD CTS RTS NJ B16 2 3 4 5 SG 7 1 2...

Страница 59: ...V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name PLC SG 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1...

Страница 60: ...iring Diagram 2 90 series SNP X Series 90 micro Series 90 30 CPU port RS 485 Wiring Diagram 3 Item Setting on PLC V7 Comm Parameter Setting Baud rate 19200 bps 19200 bps Port 01 0 for 10 1 1 0 Parity...

Страница 61: ...en assigning the indirect memory for macro programs 90 Series 90 Series SNP X Memory TYPE Remarks R data register 0 I input 1 Q output 2 Memory TYPE Remarks R data register 0 I input 1 Q output 2 M in...

Страница 62: ...CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No 0V PLC SD A RTS A 7 9 10 11 CTS A 13 21 22 RD A SD B RTS B CTS B RT RD B...

Страница 63: ...S A 13 14 15 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 15 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The m...

Страница 64: ...he CPU module RS 232C Wiring Diagram 1 EH150 HITACHI s EH RS05 cable 1 RS 232C Wiring Diagram 1 On H 252C CPU module PERIPHERAL 1 RS 232C Wiring Diagram 1 PERIPHERAL 2 HITACHI s CNCOM 05 cable 1 RS 23...

Страница 65: ...e to set within the range available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs HIDIC H Item Setting on PLC V7 Comm Parameter Setting Baud rate 7 19200 bps S...

Страница 66: ...evice C up down counter contact 8 CW as word device TS on delay timer set value 9 TC on delay timer elapsed value 10 US one short timer set value 11 UC one shot timer elapsed value 12 CS up down count...

Страница 67: ...t pair cables D sub 25 pin male D sub 15 pin male V Series CN1 Signal Name Pin No Signal Name Pin No RD PLC SD 2 3 5 SG 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use shielded twist pair cables D sub 9...

Страница 68: ...N1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RxDP TxDP RxDN PLC TxDN 1 SHELL 1 12 13 24 25 S...

Страница 69: ...hown below URX H UTX H URX L PLC UTX L 50 50 1 SHELL 1 12 13 24 25 SD SD RD RD 1 2 7 8 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as F...

Страница 70: ...Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Unit Port Connection MICRO3 MICRO3 Loader port RS 232C IDEC cable FC2A KC1 or IDEC cable FC2A KC1 Wiring Diagram 1 M...

Страница 71: ...1 3 4 GND 5 DR 6 RS 7 CS 8 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use shielded twist pair cables D sub 9 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG...

Страница 72: ...ng Diagram 2 RS 422 Wiring Diagram 6 KZ A500CPU KZ A500 CPU modular port RS 232C Wiring Diagram 3 RS 422 KEYENCE s cable KZ C20 Hakko Electronics cable MB CPUQ 1 MITSUBISHI A series link KZ L10 Port 1...

Страница 73: ...he instruction manual for KZ L10 KZ KV Series CPU Communication parameters for the V7 series are automatically set Item Setting on PLC V7 Comm Parameter Setting Port 0 0 Baud rate 19200 bps 19200 bps...

Страница 74: ...able is 57600 bps If a higher baud rate is selected communications are performed at 9600 bps Item Setting on PLC V7 Comm Parameter Setting Port 0 0 Baud rate 1 9600 bps 9600 bps Parity Even Transmissi...

Страница 75: ...er 2 TN timer current value 3 CN counter current value 4 M internal relay 6 L latch relay 7 B link relay 8 X input relay 9 Y output relay 10 TS timer contact 11 TC timer coil 12 CS counter contact 13...

Страница 76: ...le RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SD PLC RD SG 1 2 3 4 5...

Страница 77: ...e metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No Modular Connector 6 pin PLC RD SD RS CS DR SG 3 2 4 5 6 7 8 CD 1 2 3 4 5 7 SD RD RS CS SG SHE...

Страница 78: ...J2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC SDB SDA RDB RDA SG 1 7 12 13 24 25 SG SD SD RD RD 5...

Страница 79: ...12 8 12 KEYENCE PLC Please use this page freely...

Страница 80: ...rt on CPU RS 232C Wiring Diagram 1 RS 422 Wiring Diagram 4 PZ3 Universal communication port on the CPU unit RS 232C Wiring Diagram 2 RS 485 Wiring Diagram 6 SR T SR 6T Toyota version U01 DM RS 232C Wi...

Страница 81: ...on PLC V7 Comm Parameter Setting Baud rate 19200 bps 19200 bps Port 0 10 1 1 1 Parity Odd Odd Transmission code Data length 8 8 Stop bit 1 1 Functions Host link function fixed Response delay time 0 f...

Страница 82: ...10 1 for 1 SW4 DIP switch SW5 DIP switch No Setting Contents 1 ON Same as that set on V7 Normally 19200 bps 2 ON 3 ON 4 ON With parity 5 OFF Self diagnosis 6 OFF Response delay time 0 msec 7 OFF 8 OF...

Страница 83: ...SENABLE SW1 DIP switch SW2 DIP switch No Setting Contents 1 ON Unit No 1 2 OFF 3 OFF 4 OFF 5 OFF 6 OFF 7 OFF 8 OFF 1 N 9 OFF Slave No Setting Contents 1 ON Same as that set on V7 Normally 19200 bps 2...

Страница 84: ...N1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TXD RXD PLC RTS CTS 0V 2 3 4 5 7 1 2 3 4 5 7 SD...

Страница 85: ...es CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No OUT OUT PLC IN IN 14 15 16 17 0V 7 1 7 12 1...

Страница 86: ...ll of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name 0V TXD PLC TXD RTS RTS RXD CTS CTS 7 9 10 11 12 13 14 15 RXD 6 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1...

Страница 87: ...of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TXD3 TXD3 PLC RXD3 RXD3 12 13 24 25 SG 7 1 7 12 13 24 25 SG SD SD RD R...

Страница 88: ...K1000S CPU port RS 232C Wiring Diagram 3 MASTER KxxxS CNET K4F CUEA RS 232C Wiring Diagram 4 RS 422 Wiring Diagram 7 GLOFA CNET G4L CUEA GLOFA GM series CPU GM4 GM6 GM7 CPU port RS 232C Wiring Diagram...

Страница 89: ...Comm Parameter Setting Baud rate 38400 bps 38400 bps Parity Not provided Not provided Transmission code Data length 8 8 Stop bit 1 1 Memory TYPE Remarks D data register 0 M auxiliary relay 1 P input o...

Страница 90: ...ontact 9 CC counter contact 10 Memory TYPE Remarks P input output relay 0 PW as word device input read only M auxiliary relay 1 MW as word device L link relay 2 LW as word device K keep relay 3 KW as...

Страница 91: ...CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC TXD RXD GND 2 3 7 1 2 3 SD RD SHELL 8 7 1...

Страница 92: ...as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC RXD TXD GND 2 3 5 RTS CTS 7 8 CD 1 DTR 4 DSR 6 1 2 3 4 5 7 SD RD RS CS SG SHELL...

Страница 93: ...1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SD SD PLC 10 11 1 SHELL 1 12 13 24 25 SD SD RD RD 1 2 7 8 Use shielded twis...

Страница 94: ...2 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on...

Страница 95: ...14 8 14 LG PLC Please use this page freely...

Страница 96: ...rt on the CPU unit RS 232C Wiring Diagram 1 FP3 AFP3462 RS 232C Wiring Diagram 1 AFP3463 RS 422 Wiring Diagram 4 FP5 AFP5462 RS 232C Wiring Diagram 1 FP10 RS 232C tool port on the CPU unit RS 232C Wir...

Страница 97: ...hat set on V7 normally 19200 bps 2 OFF 3 OFF 4 OFF Data length 7 bits 5 ON With parity 6 ON Even 7 OFF Stop bit 1 8 OFF CS CD invalid Memory TYPE Remarks DT data register 0 X external input relay 1 WX...

Страница 98: ...5 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC SD SG 2 7 RS 4 CS 5 RD 3...

Страница 99: ...V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name PLC 1 SHELL 1 12 13 24 25 SD SD RD RD 1 2 7 8 Use shield...

Страница 100: ...ram 5 A0J2 A0J2H A0J2C214 S1 A2US A1SJ71UC24 R2 RS 232C Wiring Diagram 1 A1SJ71UC24 R4 RS 422 Wiring Diagram 5 A1SJ71UC24 PRF RS 232C Wiring Diagram 1 A1S A1SJ A2S A1SJ71C24 R2 RS 232C Wiring Diagram...

Страница 101: ...CPU Q02 Q02H Q06H Q12H Q25H Tool port 2 Q00J 00 01 CPU Q00J Q00 Q01 Tool port Select PLC Type CPU Unit Port Connection PLC2Way FX series CPU FX1 2 Tool port 1 RS 232C Hakko Electronics cable PC CX24A...

Страница 102: ...ect PLC Type dialog GX Developer MITSUBISHI programming software 1 Double click PLC Parameter 2 In the Qn H Parameter dialog click the Serial tab 3 Check Use serial communication Set the options such...

Страница 103: ...ers for the V7 series are automatically set FX Series Link A Protocol 1 Select RS 485 when the link unit FX2N 485 BD FX2N 422 BD FX1N 485 BD FX1N 422 BD or FX0N 485 ADP is used We recommend to set 2 m...

Страница 104: ...Baud rate 19200 bps 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 6 7 8 9 A B C D E F STATION No 10 STATION No 1 MODE SW11 SW12 SW13 SW14 SW15 SW16 SW17 SW18 SW21 SW22 SW...

Страница 105: ...unit is given byte address 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 6 7 8 9 A B C D E F STATION No 10 STATION No 1 MODE SW03 SW04 SW05 SW06 SW07 SW08 SW09 SW10 SW11...

Страница 106: ...data is processed as double words For those where bits or words can be used data is processed as words consisting of lower 16 bits For input Upper 16 bits are ignored For output 0 is written for upper...

Страница 107: ...iagrams with the PLC are shown below RS 232C Wiring Diagram 1 Memory TYPE Remarks D data register 0 TN timer current value 1 CN counter current value 2 1 32CN counter 32 bits 3 2 M internal relay 4 S...

Страница 108: ...2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC RD SD SG 2 3 5 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5...

Страница 109: ...J2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC SDA SDB SG RDB RDA 1 7 12 13 24 25 SG SD SD RD RD 5...

Страница 110: ...sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC FG SG...

Страница 111: ...ores are optionally available When ordering the ferrite core state GD FC ID 8 mm OD 20 mm In consideration of such noise problems it is recommended that the standard type link unit be used when the ca...

Страница 112: ...illustration below that are connected Available CPU No 1 to 30 When the V7 series reads from or writes to the CPU 1 1 in the above illustration equipped with the standard type link unit Set 31 for CPU...

Страница 113: ...ecution resulting in a communication error For more information on the macro function refer to the Reference Manual Function Also refer to the explanation on network registration contained in the oper...

Страница 114: ...however it is possible to write ladder programs or monitor the PLC memory using the V7 series without disconnecting and reconnecting the cables Applicable Models 1 n communication multi drop multi lin...

Страница 115: ...oftware it is not possible to use one COM port for both purposes at the same time Stop using either software for communications MELSEC CN1 RESET disc GPPW V SFT V6 CP MJ1 2 COM F1 F2 F3 F4 F5 F6 F7 SY...

Страница 116: ...itor are not avaliable There are two methods for enabling communications with the V SFT editor With the V609E employ the method for automatically enabling communications with V SFT At this time check...

Страница 117: ...becomes valid again Making the above baud rates the same will improve performance 4 Transferring the ladder communication program When transferring screen data the ladder communication program is als...

Страница 118: ...that the screen display speed becomes slower than usual during communications between the V7 series and the PLC even if the PLC programming software is not started 2 Also when the ladder program is tr...

Страница 119: ...16 20 16 MITSUBISHI ELECTRIC PLC Please use this page freely...

Страница 120: ...set within the range available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Unit Port Connection Modbus RTU Modbus RTU Modbus RS 232C Wiri...

Страница 121: ...3 4 GND 5 DSR 6 RTS 7 CTS 8 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use shielded twist pair cables D sub 9 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as F...

Страница 122: ...sure to set within the range available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Connection PS4 PS4 201 MM1 PRG port RS 232C Wiring Di...

Страница 123: ...1 TX RX SG PLC 3 2 5 1 2 3 SD RD SHELL 8 7 1 7 SG 5 Use shielded twist pair cables D sub 9 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell...

Страница 124: ...C2000H C500 LK203 RS 232C Wiring Diagram 3 RS 422 Wiring Diagram 4 C200HX C200HG C200HE CPU unit with built in port host link port RS 232C Wiring Diagram 2 Mounted on the CPU slot C200HW COM02 to 06 R...

Страница 125: ...rds higher 4 bits as 0 A Regards higher 4 bits as 1 Displayable range 1 word 1999 to 9999 2 words 19999999 to 99999999 SYSMAC CS1 CJ1 SYSMAC CS1 CJ1 DNA 3 CS1 CPU unit RS 232C port RS 232C Wiring Diag...

Страница 126: ...e screen as shown on the right PLC Memory Indication on V7 0000 to 9999 0 to 9999 F001 to F999 1 to 999 A000 to A999 1000 to 1999 00000000 to 99999999 0 to 99999999 F0000001 to F9999999 1 to 9999999 A...

Страница 127: ...olding relay 2 A alarm relay 4 T timer current value 5 C counter current value 6 EMn extended data memory 7 1 W internal relay 8 TU timer contact 9 Read only CU counter contact 10 Read only Example EM...

Страница 128: ...N1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RS SD CS SG 2 4 5 7 RD 3 PLC 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use...

Страница 129: ...of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SDB RDB RDA SDA 8 2 6 1 PLC SG 9 1 7 12 13 24 25 SG SD SD RD RD 5 1 2...

Страница 130: ...n No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SDB RDB RDA SDA 8 2 6 1 PLC 1 SHELL 1 12 13 24 25 SD SD RD RD 1...

Страница 131: ...m Setting Comm Parameter Detail tab and select 1 n for Connection Select System Setting Network Table Setting PLC The network table edit window is displayed Double clicking on the number brings up the...

Страница 132: ...within the range available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Unit Port Connection PCD PCD1 PGU port RS 232C Wiring Diagram 1 PC...

Страница 133: ...CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TX RX GND PLC 12 11 10 PCD7 F120 1 2 3 SD RD S...

Страница 134: ...0 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jac...

Страница 135: ...20 4 20 SAIA PLC Please use this page freely...

Страница 136: ...available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Connection SPC series SPC series RS 232C Wiring Diagram 1 RS 422 485 Wiring Diagra...

Страница 137: ...V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TR PLC TR 6 7 1 SHELL 1 12 13 24 25...

Страница 138: ...ing Diagram 3 JW 32CUH JW 33CUH Communication port 1 on the CPU unit Communication port 2 on the CPU unit RS 232C PG COMM2 Wiring Diagram 2 RS 422 PG COMM1 Wiring Diagram 5 PG COMM2 Wiring Diagram 5 I...

Страница 139: ...se TYPE when assigning the indirect memory for macro programs 1 File Register Setting on V SFT Editor Enter file number colon address in order System Memory Setting Contents 236 30H Stop bit 2 bits pa...

Страница 140: ...eries CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SD RD RTS 2 4 8 SG 7 PLC CTS 12 1 2 3 4...

Страница 141: ...G L1 L2 L4 L3 GND PLC 1 SHELL 1 12 13 24 25 SD SD RD RD 1 2 7 8 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of th...

Страница 142: ...Use TYPE when assigning the indirect memory for macro programs Only D register of SELMART is available No other devices can be used Be sure to note the above though the setting on the V SFT editor is...

Страница 143: ...LC RD RS 2 3 4 CS 5 SG 7 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use shielded twist pair cables D sub 25 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG T...

Страница 144: ...e 3964R Transmission Protocol SIEMENS s 6ES5 734 1BD20 cable 1 RS 232C Wiring Diagram 3 S5 PG port S5 series Programming port on the CPU unit 2 S7 S7 300 CP 341 3964R RK512 RS 232C Wiring Diagram 2 RS...

Страница 145: ...ess Highest MPI Address setting example If port numbers 13 and 20 are selected respectively for the PLC and the V7 series select 31 Item Setting on PLC V7 Comm Parameter Setting Baud rate 9600 bps 960...

Страница 146: ...ing example If port numbers 13 and 20 are selected respectively for the PLC and the V7 series select 31 TI500 505 TI500 505 V4 Item Setting on PLC V7 Comm Parameter Setting HMI ADP PC ADP Helmholz SSW...

Страница 147: ...0 Use memory address DB1 and later for S7 or DB3 or later for S5 I input relay 1 IW as word device read only Q output relay 2 QW as word device read only F flag internal relay 3 FW as word device rea...

Страница 148: ...TYPE Remarks V data memory 0 VW as word device I input 1 IW as word device Possible to write to the unused area Q output 2 QW as word device M bit memory 3 MW as word device T timer current value 4 C...

Страница 149: ...case of double words Please take note of this Memory TYPE Remarks V variable memory 0 WX word input 1 WY word output 2 X discrete input 3 Y discrete output 4 CR control relay 5 TCP timer counter set...

Страница 150: ...es CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RXD PLC TXD GND 2 3 5 1 2 3 4 5 7 SD RD RS...

Страница 151: ...1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No DCD PLC RXD TXD 1 2 3 DTR 4 SG 5 DSR RTS CTS 6 7 8 1 2 3 4 5 7 SD RD RS CS...

Страница 152: ...female D sub 25 pin male Signal Name Pin No V Series CN1 Signal Name Pin No T A PLC R A SG 2 4 8 T B 9 R B 11 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 15 p...

Страница 153: ...1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 9 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of...

Страница 154: ...No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC RD SD RD SD 3 8 1 SHELL 1 12 13 24 25 SD SD RD RD 1 2 7 8 Us...

Страница 155: ...24 12 24 Siemens PLC Please use this page freely...

Страница 156: ...for macro programs Select PLC Type PLC Unit Port Connection TP02 TP02 Communication Port T R T R RS 422 Wiring Diagram 1 MMI Port 9 pin 4 5 Short Computer Link Mode RS 422 Wiring Diagram 2 Item Settin...

Страница 157: ...Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name RX PLC TX PG COM 2 3 4 GND 5 RX 7 TX 8 1 7 12 13 24 25 SG SD SD RD...

Страница 158: ...LC model Be sure to set within the range available with the PLC to be used Use TYPE when assigning the indirect memory for macro programs Select PLC Type PLC Connection TSX Micro TSX Micro RS 485 Wiri...

Страница 159: ...PLC 1 0V 7 2 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables MiniDIN 9 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The...

Страница 160: ...Connection T series T series Computer link port on CPU RS 422 Wiring Diagram 1 EX series EX100 250 500 Computer link port on CPU RS 422 Wiring Diagram 2 Item Setting on PLC V7 Comm Parameter Setting...

Страница 161: ...evice Y output 2 YW as word device R auxiliary relay 5 RW as word device L link relay 6 LW as word device W link register 7 F file register 8 TN timer current value 9 Read only CN counter current valu...

Страница 162: ...D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC TX...

Страница 163: ...27 4 27 TOSHIBA PLC Please use this page freely...

Страница 164: ...Cmini Item Setting on PLC V7 Comm Parameter Setting Baud rate 9600 bps 9600 bps Port 1 1 Parity Not provided None fixed Transmission code Data length 8 8 fixed Stop bit 2 2 Memory TYPE Remarks D regis...

Страница 165: ...TR GND 2 3 4 5 DSR CTS 6 7 8 RTS 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use shielded twist pair cables D sub 9 pin female D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is use...

Страница 166: ...C Type PLC Unit Port Connection TOYOPUC L2 PC2 series PC3J CMP LINK RS 422 Wiring Diagram 1 Item Setting on PLC V7 Comm Parameter Setting Baud rate 19200 bps 19200 bps Port 0 0 Parity Even Even Transm...

Страница 167: ...as word device Y output relay 5 WY as word device M internal relay 6 WM as word device K keep relay 7 WK as word device L link relay 8 WL as word device T timer contact 9 WT as word device C counter c...

Страница 168: ...Wiring Diagram 1 0V PLC 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal sh...

Страница 169: ...29 4 29 Toyoda Machine Works PLC Please use this page freely...

Страница 170: ...s can be used data is processed as words consisting of lower 16 bits For input Upper 16 bits are ignored For output 0 is written for upper 16 bits Select PLC Type PLC Unit Port Connection M series M1...

Страница 171: ...pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SG PLC RDA RDB SDA SDB 1 7 12 13...

Страница 172: ...irect memory for macro programs Select PLC Type PLC Unit Port Connection MX series MX200 MX50 ASCII connector RS 232C Wiring Diagram 1 Item Setting on PLC V7 Comm Parameter Setting Baud rate 9600 bps...

Страница 173: ...D RS 2 3 4 CS 5 SG 7 1 2 3 4 5 7 SD RD RS CS SG SHELL 8 7 5 1 Use shielded twist pair cables D sub 25 pin male D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The m...

Страница 174: ...es Memobus port on the CPU module RS 232C Wiring Diagram 1 JAMSC 120NOM27100 RS 422 Wiring Diagram 6 PROGIC 8 PORT2 on the CPU unit RS 232C Wiring Diagram 2 CP9200SH MP900 CP9200SH CP 217IF RS 232C Wi...

Страница 175: ...imal notation Item Setting on PLC V7 Comm Parameter Setting Baud rate 19200 bps 19200 bps Port 1 1 Parity Even Even Transmission code Data length 8 8 Stop bit 1 1 Error check CRC fixed Port delay time...

Страница 176: ...Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TXD RXD RTS CTS DSR GND DTR 2 3 4 5 6...

Страница 177: ...n No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No SD RD RS CS DSR 2 3 4 5 6 CP217IF CN2 SG CD 7 8 1 2 3 4 5 7 SD...

Страница 178: ...CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No TXD RXD RXDRT RXD SG 2 3 4 6 7 PLC TXRD TXD 8 9 1 7 12 13 24 25 SG SD SD...

Страница 179: ...used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No RX RXR TRX TX 217IF CN3 1 4 5 6 RX 2 TX 7 SG 8 1 7 12 13 24 25 SG SD SD RD RD 5...

Страница 180: ...etting and available memory are the same as those for FA 500 However B common register cannot be used Select PLC Type CPU Unit Port Connection PLC2Way FA500 FA500 LC01 0N RS 232C Wiring Diagram 1 LC02...

Страница 181: ...computer link function Use The maximum baud rate available with the V7 series is 115200 bps Select the appropriate baud rate depending on the used PLC and environment Item Setting on PLC V7 Comm Param...

Страница 182: ...Remarks D data register 0 B common register 1 TP timer current value 2 TS timer set value 3 CP counter current value 4 CS counter set value 5 X input relay 6 Y output relay 7 I internal relay 8 E ext...

Страница 183: ...V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular jack 2 on the V706 is used as SG Signal Name Pin No Pin No Signal Name Pin No PLC SD ER SG DR RD RS CS 2 3 4 5 6 7...

Страница 184: ...G PLC 1 7 12 13 24 25 SG SD SD RD RD 5 1 2 7 8 SHELL 1 Use shielded twist pair cables D sub 25 pin male RJ 45 8 pin V Series CN1 V706 MJ2 1 Pin No 1 of CN1 is used as FG The metal shell of the modular...

Страница 185: ...33 6 33 Yokogawa Electric PLC Please use this page freely...

Страница 186: ...s or a V706 equipped with DU 01 is used connect the first PLC to the CN1 connector When a V706 is used connect the first PLC to MJ2 Connect the second PLC to the MJ port to MJ1 when a V706 is used PLC...

Страница 187: ...en PLCs The PLC memory data can be transferred to another PLC in blocks using a macro command For the description of 1 1 connection refer to Chapter 1 Hereunder the PLC connection at the MJ port and s...

Страница 188: ...ith PLC2Way connection at MJ port as of February 2004 are shown below MITSUBISHI OMRON SHARP YOKOGAWA Fuji Electric MATSUSHITA For the applicable PLCs refer to PLC2Way under Available PLCs in Chapter...

Страница 189: ...Using V6 TMP Use Hakko Electronics cable V6 TMP 3 m when connecting the V7 series to a PLC at the MJ port The shielded cable of V6 TMP is connected to FG frame ground when the V7 series is used and t...

Страница 190: ...hen the V706 is used Signal Name Pin No Signal Name PLC 1 SG SD RD SD RD 5 1 2 SDA FG SDB SG RDB RDA PLC SDA FG SDB SG RDB RDA PLC SDA FG SDB SG RDB RDA Use the shielded cable Modular jack 8 pin Black...

Страница 191: ...TRL PLC2Way Setting Select the PLC model and make the parameter setting as described below 1 Select System Setting Temp CTRL PLC2Way Setting Temp CTRL PLC2Way Comm Setting The Temp Control PLC2Way Com...

Страница 192: ...elect the PLC model to be connected at the MJ port Click the Setting button The Type Setting dialog is displayed Select PLC2Way The PLC manufacturer names who support PLC2Way communication are display...

Страница 193: ...ct the receive time of the response from the PLC connected at the MJ port If no response is received within the specified time a retrial is attempted Send Delay Time msec Set a time delay in sending t...

Страница 194: ...on the right Setting the PLC Memory Connected at the MJ Port 1 Open the Memory Input dialog for the part where the PLC memory connected at the MJ port should be allocated 2 For the PLC memory connect...

Страница 195: ...that is connected at the MJ port 3 Data transfer from the PLC2 memory Data in the PLC2 memory can be transferred to the PLC memory V7 internal memory or a memory card at one time according to the temp...

Страница 196: ...mment Setting dialog is displayed Enter the desired comment and click OK The entered comment is displayed at the top right corner 4 Setting data in the table Click on a line in the table The selected...

Страница 197: ...ed as a dummy word or double word In this case 0 is stored in the target memory address When the data code in the target memory address is BCD The code numerical data format for the PLC2 memory is fix...

Страница 198: ...the PLC memory Data sampling in the PLC2 memory Read Cycle sec Set the cycle of reading data in the PLC2 memory Store Target PLC Memory When storing data read from the PLC2 memory into the PLC memory...

Страница 199: ...rd Choose the desired medium for storing sampling data Internal Buffer Stores data in the internal buffer of the V7 series RAM SRAM Stores data in the SRAM area SRAM mounted on the unit V7EM S REC MCA...

Страница 200: ...tting The Memory Card dialog is opened 2 Select Buffering File for Type 3 Match the file number tab in the Memory Card dialog with Output File No in the Buffering Area Setting dialog 3 Trend sampling...

Страница 201: ...1 is transferred to the memory addresses starting from F0 Usable Devices TEMP_READ Temperature control network table read TEMP_READ F0 TABLE F1 TEMP_WRITE Data in memory addresses starting from F1 is...

Страница 202: ...er PLC2Way control function TEMP_CTL F0 F1 Return data Data stored from PLC2Way to V7 series 2 Set 0 for CPU No 1 3 The registration number is stored in special register Z105 4 If there is no user log...

Страница 203: ...the MJ port without reducing the processing capacity between the V7 the PLC When the temperature control network PLC2Way table is used If periodical reading of the PLC data is performed while the PLC...

Страница 204: ...a When Temp PLC2 is selected in the Transfer dialog only the temperature control PLC2 program can be transferred to the V7 series When the Main Menu screen is displayed after transferring screen data...

Страница 205: ...r PLC2Way Station No 12 status 743 Temperature controller PLC2Way Station No 13 status 744 Temperature controller PLC2Way Station No 14 status 745 Temperature controller PLC2Way Station No 15 status 7...

Страница 206: ...7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 MSB LSB Error 0 Bits 0 to 14 are all 0 1 Any bit 0 to 14 is not 0 Error Details Solution Timeout Although a request to send is given to the PLC connected at the MJ...

Страница 207: ...ecuted Other than 0 The macro command is forcibly executed to the stations that are working properly TEMP_CTL u100 2 TEMP_CTL u110 2 TEMP_CTL u120 2 TEMP_CTL u300 2 T t TEMP_CTL u100 2 TEMP_CTL u110 2...

Страница 208: ...ps which is higher than the one available with multi link connection described in Appendix 3 n 1 Connection Multi link PLC RS 232C RS 422 RS 485 CN1 MJ2 CN1 CN1 CN1 RUN STOP PLC RS 232C RS 422 RS 485...

Страница 209: ...apter 2 to Chapter 33 b c Connection between V7 series master station V7 slave station The connecting port for the V7 series master station depends on the selection for Multi Link either Modular Jack...

Страница 210: ...wire connection it is necessary to change the signal connection from 4 wire to 2 wire for multi link 2 connection Connect the slave station to the terminal block via 4 wire connection and then install...

Страница 211: ...RD 5 1 2 7 8 SHELL SG SD SD RD RD SG c V706 master station MJ1 Terminating resistance ON Pin No Signal Name Pin No Pin No Terminal block to be installed by the user V706 slave station MJ2 V706 slave...

Страница 212: ...22 485 ON 1 2 3 4 5 6 7 8 CF auto load MJ2 modular jack 2 terminating resistance Not used CN1 RD terminating resistance at pins 24 and 25 MJ1 modular jack 1 terminating resistance CN1 SD terminating r...

Страница 213: ...T editor Only the points different from those described in V SFT Setting 1 1 Connection page 1 10 are explained here PLC Selection Select the PLC that is connected Setting Procedure System Setting PLC...

Страница 214: ...cified for Retry Cycle This setting does not affect the communication speed if no problem is occurring however if there is any problem it does affect the communication speed When the setting value is...

Страница 215: ...App2 8 Appendix 2 n 1 Connection Multi link 2 Please use this page freely...

Страница 216: ...nection The V7 and V6 series can be used together PLC CN1 CN1 CN1 CN1 RUN STOP PLC MJ2 MJ2 MJ2 MJ2 Maximum length PLC to the terminating V7 series 500 m RS 422 RS 485 connection V7 series No 1 V7 seri...

Страница 217: ...SD SG SG TC485 FG RD RD SD SD SG TC485 FG RD RD SD SD SG TC485 Terminating resistance OFF Signal Name Shield Shield Shield To the PLC s RS 422 port of the link unit Receive data Receive data Send data...

Страница 218: ...D RD 5 1 2 7 8 SHELL SG SD SD RD RD SG SD SD RD RD 5 1 2 7 8 SHELL SG SD SD RD RD SG SD SD RD RD 5 1 2 7 8 SHELL SG SD SD RD RD SG Terminating resistance OFF Shield To the PLC s RS 422 port of the lin...

Страница 219: ...Name V MDD GD port RD terminating resistance OFF RD terminating resistance ON Pin No Signal Name Use shielded twist pair cables Signal Name Signal Name SD SD RD RD 5 1 2 7 8 SHELL SG SD SD RD RD SG S...

Страница 220: ...lay Time 0 to 255 Unit 1 msec Set a time delay in sending the response to the PLC after receipt of data from the PLC Default setting 20 msec Total 2 to 31 Set the total number of the V7 series include...

Страница 221: ...App3 6 Appendix 3 n 1 Connection Multi link Please use this page freely...

Страница 222: ...Maximum connectable PLCs 31 PLC1 PLC2 PLC3 CN1 RUN STOP RUN STOP RUN STOP RUN STOP MJ2 PLC1 PLC2 PLC3 Maximum length V7 series to the terminating PLC 500 m RS 422 RS 485 connection V7 series PLCn n 1...

Страница 223: ...ppendix Setting Procedure System Setting PLC Type Select PLC Type dialog Communication Parameter Setting Setting Procedure System Setting Comm Parameter Comm Parameter dialog Setting Items Select 1 n...

Страница 224: ...tion with the port specified with F0 that caused the failure is resumed once Usable Devices RECONNECT F0 When communication is resumed the failure information is cleared from the system memory s114 to...

Страница 225: ...App4 4 Appendix 4 1 n Connection Multi drop Please use this page freely...

Страница 226: ...at the user can create an original application by using Visual C or Visual Basic etc to allow the server to access the memory device such as V7 internal memory memory card or the PLC memory linked wit...

Страница 227: ...ith multiple PLCs on the Ethernet PLC Ethernet V7 RS 232C RS 485 V SFT PROGRAMMER PROGRAMMER F1 F2 F3 F4 F5 F6 F7 SYSTEM POWER F1 F2 F3 F4 F5 F6 F7 SYSTEM POWER Ethernet ready PLC Server PLC 1 Etherne...

Страница 228: ...ptional unit DU 01 is necessary Web server and e mail functions are available IP Address for the V7 Series To enable Ethernet communications on the V7 series it is necessary to set the IP address for...

Страница 229: ...the transceiver cable in the case of 10BASE2 or 10BASE5 6 12 VDC power supply terminal The power source is required for the transceiver of AUI connection Be sure to take account of a voltage drop at C...

Страница 230: ...Item Specifications 10BASE T Baud rate 10 Mbps Transmission method Base band Maximum network distance or maximum node interval 500 m 4 HUBs Maximum segment length 100 m between the node and the HUB M...

Страница 231: ...DU 01 V7i V706 PLC HUB HUB CU 03 V7 Distance between the node and the HUB 100 m maximum Maximum network nodes 100 Ethernet unit Node UTP cable Straight or cross cable For more information refer to the...

Страница 232: ...n the power lamp of the transceiver is not turned on check the wiring of 12 VDC power supply then replace the fuse refer to page App5 4 of the I F unit CU 03 2 For the replacement procedure refer to t...

Страница 233: ...heck the wiring of 12 VDC power supply then replace the fuse refer to page App5 4 of the I F unit CU 03 2 For the replacement procedure refer to the manual CU 03 2 OPERATING INSTRUCTIONS attached to C...

Страница 234: ...played For more information refer to Chapter 6 MONITOUCH Operations in the V7 Hardware Specifications Manual or V706 Hardware Specifications Manual Set the IP address If necessary set the default gate...

Страница 235: ...mark to Transfer through Ethernet 3 Click the Detail Setting button The IP Address Setting dialog is displayed 4 Enter the IP address of the V7 series to which the screen data is to be transferred Wh...

Страница 236: ...Appendix 5 Ethernet App5 11 5 Check the IP address and click PC 6 Data transfer is started IP address for transfer target...

Страница 237: ...the Ethernet The contents of the system setting vary depending on the method selected Check the connecting method and make the setting on the V SFT editor A Connecting to the PLC through RS 232C or R...

Страница 238: ...tion Twist pair cable Category 5 AUI connection 1 AUI cable QnH Q series Ethernet QnH Q mode QJ71E71 QJ71E71 B2 OMRON SYSMAC CS1 CJ1 Ethernet CS1 CJ1 CS1W ETN01 CJ1W ETN11 SYSMAC CS1 CJ1 Ethernet Auto...

Страница 239: ...e Setting Ethernet The Edit Network Table window is displayed Set the network table and then go back to the communication parameter setting For more information on network table editing refer to page...

Страница 240: ...5 Ethernet App5 15 Set the port number network table number of the PLC in the Memory Input dialog for each part For more information on the network table refer to page App5 16 Edit Network Table Memo...

Страница 241: ...e registered on the network table In the case of the network illustrated below the nodes with should be registered on the network table The network table is transferred to the V7 series together with...

Страница 242: ...e button Menu and Icons Each menu item corresponds to the icons as shown below File menu Import Network Table Imports a network table saved as a file ntb Export Network Table Exports a network table a...

Страница 243: ...etc to be used on the Ethernet IP Address Set the IP address When registering Ethernet ready PLC set the same IP address as that of the PLC For the setting procedure of the IP address on the PLC see...

Страница 244: ...and should be unique The IP address is 32 bit data which consists of the network address and the host address and can be classified into A to C depending on the network size Notation A string of 32 bi...

Страница 245: ...net Mask A subnet mask is used for dividing one network address into multiple networks subnet The subnet is assigned by specifying a part of the host address in the IP address as a subnet address 255...

Страница 246: ...ry EREAD F0 F1 C F2 F3 Example Macro command at the V7 A The macro command for V7 A to read data from PLC B and transfer it to PLC A is shown below Contents Two words starting from D100 in PLC B are r...

Страница 247: ...te data in V7 A to PLC B is shown below Contents Two words starting from u100 in V7 A are written into D100 in PLC B Internal Memory PLC Memory Constant Memory Card Indirect Designation Double word IP...

Страница 248: ...The macro command for V7 B to transfer data to server A is shown below Contents Two words starting from u100 in V7 B are transferred to server A Internal Memory PLC Memory Constant Memory Card Indire...

Страница 249: ...k table 5 status 526 Network table 6 status 527 Network table 7 status 528 Network table 8 status 529 Network table 9 status 530 Network table 10 status 531 Network table 11 status 532 Network table 1...

Страница 250: ...status 573 Network table 53 status 574 Network table 54 status 575 Network table 55 status 576 Network table 56 status 577 Network table 57 status 578 Network table 58 status 579 Network table 59 sta...

Страница 251: ...twork table 86 status 607 Network table 87 status 608 Network table 88 status 609 Network table 89 status 610 Network table 90 status 611 Network table 91 status 612 Network table 92 status 613 Networ...

Страница 252: ...s 0 the data before the command request is stored s518 Stores the current status of the Ethernet An error occurs if a value other than 0 is stored For more information refer to the error codes page Ap...

Страница 253: ...tion If necessary you can copy and tailor the program to your requirements Ethernet The following files are contained in the respective folders Ethernet ESmpl dsp ESmpl h ESmpl cpp ESmpl rc ESmpl clw...

Страница 254: ...Byte short Integer unsigned short WORD int Long long DWORD char String Data Type Bytes Data Range BYTE 1 0 to 255 short 2 32768 to 32767 unsigned short 2 0 to 65535 WORD 4 2147483648 to 2147483647 int...

Страница 255: ...char lpAddr int DFlag 1 Page App5 35 PLC memory Double word int HKEtn_WritePlcMemory2 DWORD sp unsigned short Wordcnt int DeviceType DWORD addr char lpAddr int DFlag 1 Page App5 36 Internal memory Wo...

Страница 256: ...OKOGAWA or YASKAWA PLCs specify a number 1 for the address addr Example D400 399 D25 24 lpAddr IP address shown as a string of characters separated by dots Example 192 168 XXX XXX DFlag 0 1 2 Refer to...

Страница 257: ...y dots Example 192 168 XXX XXX DFlag 0 1 2 Refer to page App5 31 Return values Success TRUE Failure FALSE Error details Get using HKEtn_GetLastError Read Words from Internal Memory int HKEtn_ReadInter...

Страница 258: ...emory int HKEtn_ReadPlcBitMemory int lpOnFlag int DeviceType DWORD addr int BitNo char lpAddr This function is retained until PLC data is transferred from the V7 series Parameters IpOnFlag Returns the...

Страница 259: ...ample 192 168 XXX XXX Return values Success TRUE Failure FALSE Error details Get using HKEtn_GetLastError Read Bits from Memory Card Memory int HKEtn_ReadCardBitMemory int lpOnFlag int FileNo int Reco...

Страница 260: ...block pointer Wordcnt Word count to be transferred max 2000 words DeviceType Address of the device to be written Refer to Chapter 2 to Chapter 33 addr Top memory address to be written For YOKOGAWA or...

Страница 261: ...xample 192 168 XXX XXX DFlag 0 1 2 Refer to page App5 31 Return values Success TRUE Failure FALSE Error details Get using HKEtn_GetLastError Write Words to Internal Memory int HKEtn_WriteInternalMemor...

Страница 262: ...e Bits to PLC Memory int HKEtn_WritePlcBitMemory int DeviceType DWORD addr int BitNo int OnFlag char lpAddr This function is retained until write completion is received from the V7 series It is reset...

Страница 263: ...7 series It is reset on receipt of write completion to the memory card memory Parameters FileNo File number RecordNo Record number addr Top memory address to be written BitNo Bit number to be accessed...

Страница 264: ...lues Success TRUE Failure FALSE Error details Get using HKEtn_GetLastError Cancel Receive Wait Function void HKEtn_Cancel void Cancels the function in the receive wait status such as Recvfrom Request...

Страница 265: ...Cannot process due to short memory Check the memory space at the target station 10 Illegal received data Check the command 20 Socket initialization error Check parameters for initialization 50 Reques...

Страница 266: ...ppropriate action User data format Transfer from the V7 series PLC Data Request from Server to V7 1 A request is sent from the application of the server to the V7 series Use int HKEtn_ReadPlcMemory fo...

Страница 267: ...dling in the Detail tab window of the Comm Parameter dialog a following screen is displayed The error number is displayed here Communication Error Ethernet Error XXXX The error number is displayed her...

Страница 268: ...link confirmation LED on the communication unit If the LED is not on check cable connection and the port setting on the network table 802 Transceiver error Check the transceiver and cable connection...

Страница 269: ...exceeds the limit Check the number of words that can be sent in macro editing 32 Specified table not used Check the setting on the network table 33 Cannot use the send command Check the macro command...

Страница 270: ...within the internal user memory u When a screen number is specified from the host a write action takes place to the internal memory address specified for the screen and the specified screen is then di...

Страница 271: ...connecting to the PLC only the three words shaded in the diagram below are used but when connecting to a general purpose computer all 16 words shown below are used Address Name Contents n 0 CFMDAT Sub...

Страница 272: ...s shown below The memory addresses are u0 to 16383 Assign memory addresses for system lamp data display and mode within this range 1234 1234 1234 1234 1234 0 0016 0017 0020 0030 1200 1201 1202 1350 13...

Страница 273: ...annot be used 1 n connection one computer multiple V series units A maximum of 32 V series units can be connected For wiring refer to page App6 9 The system composition for a 1 n connection is shown 1...

Страница 274: ...r communication between a general purpose personal computer and a V series unit is shown in the diagram below For V series For V706 DU 01 For V706 RS232C RS422 CN1 General purpose computer V series RS...

Страница 275: ...ta transmission Wiring Perform wiring as shown below Executing Flow Control Pin No Name Signal Name Signal Direction V Series Communication Device 1 Frame ground FG 2 Send data SD 3 Receive data RD 4...

Страница 276: ...device are shown below Wiring Perform wiring as shown below 4 wire system Manufacturer Type Hitachi Cable CO SPEV SB A 3P 3SQ Mitsubishi Cable SPEV SB MPC 3P 3SQ Pin No Name Signal Name Signal Direct...

Страница 277: ...lded cables Use twist shielded cables provided by the following manufacturers Manufacturer Type Hitachi Cable CO SPEV SB A 3P 3SQ Mitsubishi Cable SPEV SB MPC 3P 3SQ FG SD SD RD RD 1 12 13 24 25 FG RD...

Страница 278: ...G SD SD RD RD FG SD SD RD RD SG SG SG SG V TC485 SW Lower Terminating resistance ON Use twist shielded cables V TC485 SW Lower V TC485 SW Lower General purpose computer Signal Name Signal Name Signal...

Страница 279: ...as an RS 232C connector set the slide switch on the V706 to the upper position RS 232C For details refer to the separate V706 Hardware Specifications MJ2 Pin No Signal Name Contents 5 SG Signal groun...

Страница 280: ...e V706 Hardware Specifications MJ2 Pin No Signal Name Contents 1 SD RS 422 send data 2 SD RS 422 send data 7 RD RS 422 receive data 8 RD RS 422 receive data Pin No Name Signal Name Signal Direction V...

Страница 281: ...e Wiring Perform wiring as shown below 2 wire system SD SD RD RD 5 1 2 7 8 SG SD SD RD RD SG SD SD RD RD 5 1 2 7 8 SG SD SD RD RD SG SD SD RD RD 5 1 2 7 8 SG SD SD RD RD SG FG RDA RDB SDA SDB SG Termi...

Страница 282: ...SD SD RD RD 5 1 2 7 8 SG SD SD RD RD SG SD SD RD RD 5 1 2 7 8 SG SD SD RD RD SG FG RDA RDB SDA SDB SG Terminating resistance ON General purpose computer Signal Name Terminating resistance OFF Termina...

Страница 283: ...hat will communicate with the V series 1 From the menu bar go to System Setting and click on PLC Type 2 The Select PLC Type dialog comes up Select Universal Serial and click the OK button Communicatio...

Страница 284: ...or Connection and enter Local No It is possible to set the transmission mode by going to the Detail tab window and making settings for Trans Mode Setting Items Baud Rate Set the communication speed be...

Страница 285: ...Function n 3 SW0 switch data No 0 n 4 SW1 switch data No 1 When the switch output memory is set at an address location from 80 to 95 in the system memory s of internal memory the switch number is writ...

Страница 286: ...number 001 002 Overlap 0 Status 0 OFF 1 ON 003 Overlap 1 Status 0 OFF 1 ON 004 Overlap 2 Status 0 OFF 1 ON 080 Universal serial port switch output 0 Output code 0 15 081 Universal serial port switch...

Страница 287: ...play Set the top memory number The relationship between memory and the calendar is shown in the following table Calendar settings are performed in the read area under RCVDAT n 0 at the leading edge of...

Страница 288: ...t tries to access to the read clear area is shown in the following diagram Following allocation of the read clear backup area backup data of the system memory write area is stored as shown below Defau...

Страница 289: ...mally V series uses the same cables to send or receive data See the diagram below For this reason send output remains OFF High impedance except for sending signals from V series However depending on t...

Страница 290: ...fer to 1 Before Connecting to PLC The mode contents are as follows Connection mode 1 1 Used when one host communicates with one V series unit 1 1 1 n A maximum of 32 V series units are possible to be...

Страница 291: ...F 2 F 3 F 1 F 4 F 5 F 6 F 7 C o m m a n d Transmission data Part A Transmission data Part B Transmission data Part A Transmission data Part B D L E D L E S T X D L E Error code D L E E T X S U M S T...

Страница 292: ...a macro command is run Interrupt timing When an interrupt condition occurs while the host is transmitting a command or before the V series machine transmits a response the interrupt code will be tran...

Страница 293: ...5 F 6 F 7 C o m m a n d Transmission data Part A Transmission data Part B Transmission data Part A Transmission data Part B D L E D L E S T X D L E Error code D L E E T X S U M C R L F S T X N A K C R...

Страница 294: ...a macro command is run Interrupt timing When an interrupt condition occurs while the host is transmitting a command or before the V series machine transmits a response the interrupt code will be tran...

Страница 295: ...C o m m a n d HL S t a t i o n N o S t a t i o n N o Transmission data Part A Transmission data Part B Transmission data Part A Transmission data Part B D L E D L E S T X D L E Error code D L E E T X...

Страница 296: ...mission data Part A Transmission data Part B Transmission data Part A Transmission data Part B D L E D L E S T X D L E Error code D L E E T X S U M C R L F S T X N A K C R L F E T X S U M C R L F HL S...

Страница 297: ...tted as command WM data writing address 05AD 1453 and memory data OF2A 3882 in transmission mode w o CR LF w sum check However in the case of an interrupt data from ENQ to ETX is subject to a sum chec...

Страница 298: ...ed within the specified time an NAK 01 BUSY signal is sent In this case it is necessary to retransmit the command When Busy Time is set as 0 the machine waits until the display is complete and then a...

Страница 299: ...s for which global port number are active are shown below If commands other than these are used a command error will occur Responses to global port numbers are not transmitted to the host However resp...

Страница 300: ...to be read HEX ASCII Count Number of characters to be read HEX ASCII When the data to be read is not continuous DLE is inserted as a delimiter between the breaks V series side Address and count are o...

Страница 301: ...is inserted as a delimiter between the breaks V series side Address Top address of the data memory to be read HEX ASCII Count Amount of data memory to be read HEX ASCII The read sequence is the same...

Страница 302: ...64H EF Address 0101 0065H GH Address 0102 0066H IJ Address 0103 0067H KL Host side There should be no more than 5 DLEs Address Address of the memory to be written HEX ASCII Count Number of write chara...

Страница 303: ...ld be no more than 5 DLEs Address Address of the memory to be written HEX ASCII Count Data memory contents to be written HEX ASCII When write data is not continuous DLE is inserted as a delimiter betw...

Страница 304: ...NAK error code 01 is returned Retry command HL T R E T X S T X S U M A C K Error code 01H Command A Host side V series side In the case that error code 01 is returned command A is on standby as the V...

Страница 305: ...ed Screen internal switching Interrupt when the screen changes based on an internal switch Macro OUT_ENQ Interrupt enabled all the time Example Interrupt settings are shown below Switch ON Prohibited...

Страница 306: ...Prohibited HL R I S T X E T X S U M HL HL S T X E T X S U M D a t a Interrupt status read command Host side V series side 07 06 05 04 03 02 01 00 Switch ON 0 Interrupt prohibited 1 Interrupt allowed S...

Страница 307: ...7 Refer to page App6 16 For RS 422 485 2 wire connection interrupts cannot be used HL 02 SW0 SW1 ENT0 ENT1 ENT2 WORD WORD WORD WORD WORD WORD SCREEN2 SCREEN5 When a screen internal switching occurs V...

Страница 308: ...Use the macro command OUT_ENQ For details refer to Chapter 13 in the Reference Manual Function HL xx WORD WORD 00 HL xx WORD WORD 01 Interrupt with a macro command OUT_ENQ Word transmission Transmiss...

Страница 309: ...t However if you go from the menu bar to System Setting to Function Switch Setting or if you go from the menu bar to Edit to Local Function Switch Setting and check Use Function Switch it is possible...

Страница 310: ...rity error is detected in the received data Send the command again 04H Sum check error A sum error occurs with the received data 05H Address error The address specified by the memory read write comman...

Страница 311: ...12 words Write CHR command 1024 bytes 0BH Retry command error When a retry command is received there is no BUSY status NAK 01 command 0FH ETX error No ETX code is found 10H DLE error There is no DLE c...

Страница 312: ...s App6 43 1 byte Character Code List 2 SP 3 0 1 2 3 4 5 6 7 8 9 4 A B C D E F G H I J K L M N O 5 P Q R S T U V W X Y Z _ 6 a b c d e f g h i j k l m n o 7 p q r s t u v w x y z 8 9 E F 1 0 0 1 2 3 4...

Страница 313: ...em memory s User Memory u 16384 words are available for user memory This area is usable as desired for screen data Also the host computer can write to and read from the area The memory map is as shown...

Страница 314: ...output 1 Output code 16 31 82 Universal serial port switch output 2 Output code 32 47 83 Universal serial port switch output 3 Output code 48 63 84 Universal serial port switch output 4 Output code 64...

Страница 315: ...2 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 MSB LSB 00 16 01 17 02 18 03 19 04 20 05 21 06 22 07 23 08 24 09 25 10 26 11 27 12 28 13 29 14 30 15 31 MSB LSB 00 224 01 225...

Страница 316: ...NO No External Switch ON Interlock Yes Satisfied Not satisfied Interlock condition Lamp Lamp ON graphics Buzzer ON Output ON macro Execution Continue ON macro Yes ON macro End No External Buzzer Buzze...

Страница 317: ...App6 48 Appendix 6 Universal Serial Communications Please use this page freely...

Страница 318: ...be collected through communications with the V7 series Data collection is available even between the products of different manufacturers When connecting to the V7 series or a V706 equipped with DU 01...

Страница 319: ...e determined depending on the connecting method For the wires not used be sure to properly insulate with tape etc RS 232C V7 series 1 set Wiring example of above a 0V SG RD SD 5V SD RD SD RD V6 TMP Br...

Страница 320: ...1 RS 232C RS 485 conversion Terminal block Terminal block Terminal block 0 5 m recommended 1 0 m maximum 1 RS 485 2 1 2 a b SG 5 SG 5 SG SG SG FG FG FG 1 1 Signal Name V7 series Modular jack 8 pin Pin...

Страница 321: ...ar jack to be used Modular Jack 1 Modular Jack 2 Baud Rate 4800 9600 19200 38400 57600 115k bps Local Port 1 to 31 Set the port number of the V7 series Send Delay Time msec Set a time delay in sending...

Страница 322: ...Model Type Address Reserved for system V7 internal memory PLC memory within 16 bits Temperature cotrol PLC memory within 16 bits Memory card 2 2 4 10 2 4 2 2 2 4 2 2 2 2 4 4 4 Read target memory setti...

Страница 323: ...Bytes Model Type Address Reserved for system V7 internal memory PLC memory within 16 bits Temperature cotrol PLC memory within 16 bits Memory card 2 2 4 10 2 4 2 2 2 4 2 2 2 4 6 4 Write target memory...

Страница 324: ...nts STX 02H Start of transmission block ETX 03H End of transmission block CR 0DH Carriage return LF 0AH Line feed Name Code Hexadecimal ASCII Contents Read 20H 32 30 Read from memory Write 21H 32 31 W...

Страница 325: ...m Check Code SUM 2 bytes Data is added up SUM and the lower one byte 8 bits of the sum is converted into the 2 digit ASCII code hexadecimal A sum check code is shown below Example Transmission mode wi...

Страница 326: ...Send the command again 04H Sum check error A sum error occurs with the received data 06H Count error The memory read write count is 0 0FH ETX error No ETX code is found 11H Character error A character...

Страница 327: ...yte Character Code List 2 SP 3 0 1 2 3 4 5 6 7 8 9 4 A B C D E F G H I J K L M N O 5 P Q R S T U V W X Y Z _ 6 a b c d e f g h i j k l m n o 7 p q r s t u v w x y z 8 9 E F 1 0 0 1 2 3 4 5 6 7 8 9 A B...

Страница 328: ...4 Manufacturer PLC 1 1 1 n Multi drop Multi link 2 n 1 Multi link Ethernet Field Network Controller Network PLC2Way Allen Bradley PLC 5 SLC500 Micro Logix 1000 Control Logix Automationdirect Direct LO...

Страница 329: ...S series CPU FX series link A Protocol 3 A link Net10 1 MODICON Modbus RTU MOELLER PS4 OMRON SYSMAC C OPCN 1 2 SYSMAC CV 2 SYSMAC CS1 CJ1 2 SYSMAC CS1 CJ1 DNA 1 SAIA PCD SAMSUNG SPC series N_plus SECN...

Страница 330: ...Ethernet Field Network Controller Network PLC2Way Allen Bradley PLC 5 SLC500 Micro Logix 1000 Control Logix Automationdirect Direct LOGIC Direct LOGIC K Sequence Baldor Mint DELTA DVP series FANUC Pow...

Страница 331: ...PU 6 FX2N series CPU FX1S series CPU FX series link A Protocol 3 A link Net10 1 MODICON Modbus RTU MOELLER PS4 OMRON SYSMAC C 2 SYSMAC CV 2 SYSMAC CS1 CJ1 2 SYSMAC CS1 CJ1 DNA 1 SAIA PCD SAMSUNG SPC s...

Страница 332: ...awa 924 0035 Japan TEL 076 274 2144 FAX 076 274 5208 TEL 03 3255 0166 FAX 03 3255 0298 238 Kamikashiwano machi Matto shi Ishikawa 924 0035 Japan Tokyo Office Head Office Sales TEL 06 6385 8234 FAX 06...

Отзывы: