5. INITIAL SETUP
When connecting or disconnecting the
cord assembly, hold the plug.
Be sure to turn off the power switch before connecting or
disconnecting the cord assembly for the handpiece to
and from the receptacle to avoid damaging the unit.
The HAKKO FM-2029 can be connected to channel 3 connector.
Insert the plug until it stops and try to remove it without pressing the release pin.
If it stays in the receptacle, it is properly seated.
NOTE :
Push on the plug until it stops, making sure it is securely connected.
2. Connect the tube of the handpiece to HAKKO FM-206.
(Fig.3)
3. Insert one end of the connecting cable into the jack at the back of the handpiece holder
and the other end into the jack at the back of the station to connect them. (Fig.4)
Connecting cable
When using the HAKKO FM-2029, be sure to
insert the connecting cable for the handpiece
holder into the jack for channel 3. Inserting the
connecting cable into the incorrect jack
will cause the system to not function
correctly.
NOTE :
●
●
B. Connect to HAKKO FM-206
1. Connect the cord assembly of HAKKO FM-2029 to channel 3 connector for HAKKO FM-206. (Fig.2)
●
●
19
(Fig.2)
(Fig.3)
(Fig.4)