6. OPERATION

Controls and displays

Controls

UP

DOWN

The front panel of the Hakko 942 soldering
station has the following controls:
• A power on/o

f

f switch.

• Four control buttons:

 – Initiates a data entry mode.

 – End of sequence signal (terminates a

phase of a data entry mode); when
pressed  for  less  than  one  second,
displays settings already stored.

 – increases the value in the appropriate

display window .

 – decreases the value in the appropriate

display window .

1. Turn the power switch ON.

2. Once the temperature is reached, the buzzer

sounds.  The heater lamp at the lower right of
the  temperature  display 

  starts

blinking.

CAUTION:

Place the iron in the iron holder when not in use.

CAUTION:

The Hakko 942 is preset at 350

°

C. at the factory .

Check  the  temperature  setting  by  pressing  the 
button.
The set temperature will be displayed for two seconds.

Displays

The  Hakko  942  has  a  three-digit  display
element. Depending upon the selected mode, it
will display:
• Normal mode:

Sensor temperature (tip temperature)

• Data entry:

Selected quantity (see ‘data entry procedures’
for exact characteristics)

• Temperature scale:

°

C or 

°

F, depending upon selection

• Error detection:

Refer to ‘ERROR MESSAGES’  section

In addition, a single heater lamp will flash when
the station has reached the desired temperature,
indicating that it is ready for use.

An  audible  buzzer  is  provided  to  alert  the
operator when:
1. The station has reached the set tempera-

ture. The buzzer will sound once.

2. The low temperature threshold has been

crossed.  This buzzer will shuto

f

f when the

sensed  temperature  returns  to  the
acceptable range.

3. A failure has occurred in the sensor or heater

(including the sensor circuit). 

The buzzer will

sound

 

 

 

  

continuousl

y.

4. The auto power shuto

f

f is activated and the

power to the heating element is shuto

f

f, the

buzzer will sound three times.

Heater lamp

UP

DOWN

6

Содержание 942

Страница 1: ...High output temperature controlled soldering station...

Страница 2: ...Power consumption Temperature range Temperature stability Hakko 942 soldering station Power consumption Tip to ground resistance Tip to ground potential Length less cord Weight less cord Length of co...

Страница 3: ...metal parts near the tip Donotallowthetiptocomecloseto ortouch flammablematerials Informothersintheareathattheunitishotandshouldnotbetouched Turnthepoweroffwhennotinuse orleftunattended Turnthepowero...

Страница 4: ...RT NAMES Tip tray OFF ON Heat resistant pad Iron holder Cleaning sponge Tip not included Hakko 912 Soldering iron Power cord Fuse Power receptacle Station Power switch Receptacle Control card Card cha...

Страница 5: ...2 4 1 5 INITIAL SETUP A Iron holder 1 Adjusttheheightoftheironholdertosuit as follows i Loosentheadjustingscrews ii Settheironholdertothedesiredheight iii Tightenthescrews 2 Put the small cleaning sp...

Страница 6: ...grounded wall socket The Hakko 942 is protected against electrostatic discharge and must be groundedforfullefficiency To remove the cord draw the plug from the receptacle while pressing the release p...

Страница 7: ...ll be displayed for two seconds Displays The Hakko 942 has a three digit display element Dependingupontheselectedmode it willdisplay Normalmode Sensortemperature tiptemperature Dataentry Selectedquant...

Страница 8: ...2willoperatenormallywiththecardinserted If power is turned on with the card inserted the station will heat to the temperature set before thecardwasinserted Changing the temperature setting Example 350...

Страница 9: ...g the tip a Always turn the power OFF when removing orinsertingatip b Hold the tip with the heat resistant pad and pullitout c Insert the new tip fully into the Hakko 912 If the tip is not fully inser...

Страница 10: ...dif ference if any between 400 C 750 F and the measured tip temperature Record this value See the example following to determine what value to enter as the offset for that particular tip When entering...

Страница 11: ...by pressing the button The system will automatically sequence to auto power shutoff mode 2 Auto power shutoff This is an optional setting When it is activated and the soldering iron is not used for 3...

Страница 12: ...of allowable low temperature alarm tolerance For C 30 150 C For F 50 300 F When the station enters low temperature alarm tolerance setting mode the hundreds digitbegun flashing Enterandstorethevalue...

Страница 13: ...off is not active Neverallowtheunittoidleatahightemperature for extended periods This will allow the tip to becomeoxidized TurnthepowerswitchOFF If it is to be out of service for several hours it is a...

Страница 14: ...room temperature performthetipmaintenancedescribedonp 12 If the value still does not decrease check the connectioncordforbreakage Checking the connection cord for breakage 1 Removethesolderingtipandt...

Страница 15: ...he warning buzzersounds Whenthetiptemperaturerises to a value within the set tolerance the buzzer willstopsounding 350 C 400 C 50 C Low temperature alarm tolerance Set temperature OR 650 F 750 F 100 F...

Страница 16: ...onnectioncordand ortheheater sensorfor breakage Solder does not wet the tip CHECK Isthetiptemperaturetoohigh ACTION Settheappropriatetemperature CHECK Isthetipcontaminatedwithoxide ACTION Remove the o...

Страница 17: ...ion 100 120V 220 240V With power receptacle rubber feet 4 ea India Item No 1 2 3 4 5 6 Part No B2579 B2388 B2580 B2712 B2581 B2662 B2715 B2583 B2716 B2717 B2582 Name Cover Control card P W B temperatu...

Страница 18: ...Parts Item No 1 2 3 4 5 6 7 Part No B2390 B2389 A1427 B2391 B2667 B2572 B2607 Name Iron receptacle Iron holder base Cleaning sponge Bottom plate Rubber foot Retaining clip Tip tray Description With t...

Страница 19: ...10 0 8 1 6 1 2 2 4 0 5 0 5 0 5 T2 08D Shape 0 8D T2 12D Shape 1 2D 10 T2 16D Shape 1 6D T2 24D Shape 2 4D 10 T2 52 Shape 5 2D 90 23 7 113 7 5 5 7 5 T2 B Shape B R 0 2 T2 32D Shape 3 2D Unit mm 1 2 1...

Страница 20: ...sg MALAYSIA HAKKO PRODUCTS SDN BHD MALAYSIA HEAD OFFICE NO 22 JALAN PEMBERITA U1 49 SEKSYEN U1 TEMASYA INDUSTRIAL PARK 40150 GLENMARIE SHAH ALAM SELANGOR DARUL EHSAN WEST MALAYSIA TEL 03 5569 5223 FAX...

Отзывы: