16
Permissible loads on standards
When calculating permissible construction heights for the scaffold, the following
permissible loads on standards can be applied for different combinations of lift height
and vertical distances between ties.
1 kN = 100 kp
Lift height [m]
Vertical distance
between ties [m]
Permissible standard load [kN]
Base jack max.
Base jack min.
Vertically braced
using SKRD
2.0
2.0
4.0
16.4
9.5
20.9
9.8
16.4
9.5
The support surface must be capable of withstanding a design load per standard of twice
the relevant permitted load on a standard.
When scaffolding is suspended, standard joints must be locked using 16 mm pins. The
permissible tensile load on a standard in a suspended scaffold is 20.0 kN.
When designing using the partial coefficient method, the design bearing capacity is
obtained by multiplying the permitted load by 1.5.
LOADING CONDITIONS