Quick Instruction
9 of 15
Tel.:+82 32 327 4712 www.haiyang.co.kr
HIS-700R, Cable colour Function
Red
Power supply, positive DC +9 ... +28V
Black
Power supply, negative (and signal ground)
White
NMEA-out (+), AIS-Data ,
Green
NMEA-out (-), AIS-Data
Yellow Additonal
NMEA-in
(+), e.g. GPS-data
(optional)
Brown Additonal
NMEA-in
(-), e.g. GPS-data
(optional)
1.5.2
Connection and settings of the Chartplotter
The only thing you have to do is:
to connect the white (out +) cable to your input (+) of the NMEA port
to connect the green (out – ) cable to your input (-) of the NMEA port
Please find details of the settings in your Chartplotter manual. Every
chartplotter is a little bit different.
Nevertheless the main settings of your input NMEA channel should be:
Select the right input channel at your Chartplotter. (Some do have up to 3
and more input channels)
Set transmission data rate to 38400
Set the input channel of the chartplotter to the following bit configuration:
8/N/1