background image

Xiamen Haiwell Technology Co., Ltd

www.haiwell.com

A1

6D

I

0
4
8
12

1
5
9
13

2
6
10
14

3
7
11
15

PWR

LINK

Digital Module User Manual

Haiwell PLC User Manual

A Series Card-type PLC

Содержание A Series

Страница 1: ...Xiamen Haiwell Technology Co Ltd www haiwell com A16DI 0 4 8 12 1 5 9 13 2 6 10 14 3 7 11 15 PWR LINK Digital Module User Manual Haiwell PLC User Manual A Series Card type PLC ...

Страница 2: ...ion 3 2 Indicator Description 4 3 Power Supply Specification 4 4 Environmental Specifications for Product 4 5 Digital Input DI Specification 4 6 Digital Output DO Specification 4 7 Digital Input Output DI DO Wiring Diagram 5 8 Terminal Wiring Diagram 5 9 Module Parameter Table 5 10 Extend module Installation 6 ...

Страница 3: ...DC24V 0 1A MAX A16DOR DC24V 0 35A MAX A16DOT DC24V 0 35A MAX A16DOP DC24V 0 35A MAX A16XDR DC24V 0 2A MAX A16XDT DC24V 0 2A MAX A16XDP DC24V 0 2A MAX A16DI 0 4 8 12 1 5 9 13 2 6 10 14 3 7 11 15 PWR RUN 1 3 S S X0 X1 X2 X3 X4 X5 X6 X7 X8 S S X9 X10 X11 X12 X13 X14 X15 4 5 2 6 7 8 9 95 0 25 0 65 0 14 0 1 Digital channel indicator 8 Module expansion port 2 PWR power indicator link running indicator 9...

Страница 4: ...age for input and expansion None Isolation type No Electrical isolation Power protection DC input power polarity reverse over voltage protection 4 Environmental Specifications for Product Item Environment Specification Temperature Humidity Operating temperature 0 55 Storage temperature 25 70 Humidity 5 95 RH No condensation Vibration resistance 10 57 HZ amplitude 0 075mm 57HZ 150HZ acceleration 1G...

Страница 5: ...munication protocol The low 4 bit of the low byte 0 N 8 2 For RTU 1 E 8 1 For RTU 2 O 8 1 For RTU 3 N 7 2 For ASCII 4 E 7 1 For ASCII 5 O 7 1 For ASCII 6 N 8 1 For RTU The high 4 bit of the low byte 0 2400 1 4800 2 9600 3 19200 4 38400 5 57600 6 115200 03H 06H Module name 07H 08H Default IP address 192 168 1 111 09 0AH Reserve 0BH High byte subnet mask b3 b0 1indicates 255 0 indicates 0 for exampl...

Страница 6: ...parallel interface on the lower right side of the previous module host or expansion module is inserted into the parallel interface on the lower left side of the next module and hooked with small cards on both sides The parallel interface on the right side of this module is used as the next expansion module Connect all expansion modules in this way in sequence Thanks for choosing Haiwell Products I...

Отзывы: