MANOK plus
Maintenance
92
Order h49 7144.907-333
11 Maintenance
11.1 Maintenance safety
WARNING
Serious injuries caused by parts being ejected
centrifugally after a loss of clamping power!
Maintain the maintenance and cleaning intervals
of the product at all times.
It is essential to check the maintenance status of
the product at regular intervals with a structural
clamping force measurement.
CAUTION
Health risks caused by incorrect handling of
cleaning agents!
Pay attention to hazard specifications and the
safety data sheet of the manufacturer.
INFORMATION
If necessary, use any forcing / extraction threads in
the components of the product, changing parts or
clamping elements.
11.2 Maintenance schedule
The following sections describe the maintenance work
needed to ensure optimum and fault-free operation.
If increased levels of wear are detected during regular
checks, shorten the maintenance intervals to reflect the ac-
tual rate at which signs of wear appear.
Contact the manufacturer for questions relating to mainte-
nance work and maintenance intervals [see »Contact« chap-
ter].
Interval
Maintenance work
daily
Visual inspection of clamping and mating surfaces for signs of
wear, nicks and cracks [see »Visual inspection« chapter]
Visual inspection of rubber on clamping element for signs of
wear, nicks and cracks [see »Visual inspection« chapter]
Complete cleaning if heavily soiled [see »Cleaning« chapter]
Conduct a structural clamping force measurement
weekly or after 40 operating
hours*
Remove the clamping element [see »Removal of the clamping
element« chapter]
Clean the clamping element, clamping taper and coupling area
[see »Cleaning« chapter]