Name
Description
Module set to address
Comfort lighting
Reacts to the Lights ON and Lights OFF button on your key chain
remote control.
C1 and C2
Exit delay
Lights are switched on during the exit delay.
C1 and C2
Alarm lighting
In the case of an alarm, the lights will flash during 4 minutes and
then remain on.
C1 and C2
Status indicator
The lights are switched on when the system is set to ARM AWAY.
D1
External Siren PH7208
Extra 110dB siren.
C1 or C2
Extra universal siren
Connect your own siren to a
Haibrain
AM12 or AD10 module.
D2
To change the HouseCode:
1. To access the menu, press the menu
or menu
button. The display will now read ‘ENTER PIN’.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). For every digit entered, a * will appear
on the display.
3. When the PIN code has been entered correctly, the word ‘INSTALL’ will show up on the display.
4. Use the menu buttons
/
to go to menu item 7. OPTIONS. Press OK to select this menu item. You can also go to this menu
item directly by pressing a 7 on the number pad.
5. Use the menu buttons
/
to go to menu item HOUSECODE. Press OK to select this menu item.
6. Use the menu buttons
/
to select the desired HouseCode and press OK.
7. Press CLEAR again to quit the menu.
Did you already have several
Haibrain
X-10 modules installed before installing the security system? Then you may need to change
the basic UnitCode for the system. This means you do not need to change the addresses of the existing system.
If you change the UnitCode of the console, the addresses for the Home Automation functions also change. Example: You change
the UnitCode from 1 into 5:
Name
Description
Module set to address
Comfort lighting
Reacts to the Lights ON and Lights OFF button on your key chain
remote control.
A5 and A6
Exit delay
Lights are switched on during the exit delay.
A5 and A6
Alarm lighting
In the case of an alarm, the lights will flash during 4 minutes
A5 and A6
B5
A5 or A6
and then remain on.
Status indicator
The lights are switched on when the system is set to ARM AWAY.
External Siren PH7208
Extra 110dB siren.
Extra universal siren
Connect your own siren to a
Haibrain
AM12 or AD10 module.
B6