17
HAIKU
®
HOME
Make sure power is disconnected from the fan location before installing the mounting plate or
mounting bracket!
Low Profile Mount
Drill four Ø 8 mm holes in the pattern shown. The hole depth should not exceed 40 mm.
Remove any dust from the holes. Insert four anchor bolts (
a
) into the holes. Strike the heads of the anchor bolts with a hammer, ensuring the bolt
sleeves are flush with the ceiling surface.
Position the mounting plate (
b
) on the anchor bolts. Ensure all four anchor bolts are fully tightened to expand and lock the anchors.
If required by local building and safety codes, install an anchor hook (
c
) for the safety cable. Drill a Ø 14 mm hole for the anchor hook in the
pattern shown. The hole depth should not exceed 50 mm. Remove any dust from the hole, and then insert the anchor hook and fully tighten.
Standard Mount
Drill three Ø 12–12.5 mm holes in the pattern shown. The hole depth should not exceed 35–40 mm.
Remove any dust from the holes. Insert three anchor bolts (
a
) into the holes. Strike the heads of the anchor bolts with a hammer, ensuring the
bolt sleeves are flush with the ceiling surface.
Position the hanger plate (
b
) on the anchor bolts. Ensure all three anchor bolts are fully tightened to expand and lock the anchors.
If required by local building and safety codes, install an anchor hook (
c
) for the safety cable. Drill an Ø 8–8.5 mm hole for the anchor hook adjacent to
the hanger plate. The hole depth should not exceed 35–40 mm. Remove any dust from the hole, and then insert the anchor hook and fully tighten.
Universal Mount
Drill three Ø 6 mm holes in the pattern shown. The hole depth should not exceed 40 mm.
Remove any dust from the holes. Insert three anchor bolts (
a
) into the holes. Strike the heads of the anchor bolts with a hammer, ensuring the
bolt sleeves are flush with the ceiling surface.
Position the mounting bracket (
b
) on the anchor bolts. Ensure all three anchor bolts are fully tightened to expand and lock the anchors.
If required by local building and safety codes, install an anchor hook (
c
) for the safety cable. Drill an Ø 8 mm hole for the anchor hook. The hole
depth should not exceed 50 mm. Remove any dust from the hole, and then insert the anchor hook and fully tighten.
!
Содержание B3213-X4
Страница 1: ...INSTALLATION GUIDE INSTALLATION GUIDE...
Страница 4: ...NOTES...
Страница 15: ...13 HAIKU HOME Outlet Box Page 14 4a Concrete Ceiling Page 16 4b Wood Ceiling Joist Page 18 4c...
Страница 23: ...21 HAIKU HOME Standard Mount Page 30 Universal Mount Page 42 5b 5c...
Страница 24: ...22 REV D 2015 HAIKU HOME ALL RIGHTS RESERVED MOUNTING LOW PROFILE 5a a a 1 INSTALL RUBBER BUMPERS...
Страница 25: ...23 HAIKU HOME Slide the rubber bumpers a onto the extension tube brackets STEP COMPLETED 1...
Страница 32: ...30 REV D 2015 HAIKU HOME ALL RIGHTS RESERVED MOUNTING STANDARD 5b b a 1 POSITION WIRING COVER AND TRIM...
Страница 57: ......
Страница 58: ......
Страница 60: ...HKU INST 98 ENG 01 H...