Connect the hose to a water tap using the enclose parts and in
accordance with the installation instructions.
Water pressure:
Minimum 0.03MPa, maximum 0.6MPa.
If the water pressure is higher, install a pressure reducing valve.
Water temperature
We recommend that you use cold water.
If you do use hot water, the temperature should not exceed
60
℃.
Electrical connection
This appliance should only be connected to a 220V-240V~
source via a properly installed earth socket. See rating plate
for size of required fuse.
Disconnecting the dishwasher
Here too, it is important that tasks are carried out in the correct
Protection from freezing
temperature
If the appliance is installed in a location where there is a risk
of freezing temperature (e.g. in a holiday home), all water must
be completely drained out of the interior .
Turn OFF the tap, disconnect the supply hose and allow to
drain.
Height adjusting
- The appliance is built-up from a dishwasher and an adjust-
able base. It can fit in with kitchen cabinets at a height of
800mm or 850mm.
- The original height of the appliance is 850mm. you can ad-
just the height as follow.
In order to function correctly the dishwasher must be properly
installed. Specifications for the water intake and waste-water
drainage, as well as electrical connections, must fulfil the cri-
teria that are set out in the following paragraphs and the in-
stallation instructions.
When installing the dishwasher, carry out tasks in the follow-
ing order:
- Check contents of delivery upon receipt,
- Site dishwasher,
- Connect drainage hose,
- Connect inlet hose to water supply,
- Connect dishwasher to power supply.
Checking contents of delivery
All functions of your dishwasher have been thoroughly tested
in the factory. A small number of water marks have been left
on the dishwasher as a result. They disappear as soon as the
appliance is used for the first time.
Sitting the dishwasher
Dimensions associated with sitting the dishwasher are con-
tained in the installation instructions. Ensure that the appli-
ance is completely level by adjusting the feet. Make sure that
it is standing on a firm surface.
Drainage connection
See the installation instructions for details of procedure to be
followed.
If necessary, fit a siphon trap (U-bend) with a connecting piece
for the drainage hose. Connect the drainage hose to the trap
using the enclosed parts.
Installation
Fresh-water connection
sequence:
always switch off the appliance from the mains power supply
first of all.
Pull plug out of wall socket.
Turn off water supply.
Disconnect drain and water input hoses. Remove screws in
underside of work surface. Detach plinth, if fitted.
Pull out appliance and carefully withdraw hoses at the same
time.