TROUBLE SHOOTING
Long Wash Times
Incoming water should be at least 120 F
o
If the incoming water is below that level,
the heating element will be energized
during the wash and rinse cycle until the
temperature of the water reaches a
preset level, depending on the option.
The cycle will be extended for the period
of time that the heating element is on.
The heater will draw approximately
10.5 amps and can be checked for
operation with an amp probe.
Содержание UNDERCOUNTER DISHWASHER
Страница 1: ...HAIER UNDERCOUNTER DISHWASHER Training Presentation ...
Страница 2: ...CONTROL PANEL POWER BUTTON In to RUN OUT to STOP ...
Страница 11: ...INNER DOOR PANEL Rinse Aid Dispenser Detergent Dispenser closed Door Latch Convection Dry Fan Cover ...
Страница 12: ...DETERGENT CUP Main Wash Detergent Cup Rinse Aid Dispenser setting Rinse Aid Dispenser cap off Pre Wash Cup ...
Страница 15: ...DETERGENT CUP Solenoid Test Test Solenoid and check for actuation of door release and rinse aid plunger ...
Страница 17: ...CONVECTION DRY FAN Testing 32 ohms resistance Test at quick disconnect ...
Страница 18: ...CONVECTION DRY FAN Removal IMPORTANT Remove cover retaining screw ...
Страница 22: ...CONTROL PANEL SERVICE Electronic Control Remove 2 Screws Pry PC Board off of posts ...
Страница 24: ...CONTROL PANEL SERVICE Electronic Control Connections ...
Страница 26: ...CONTROL PANEL SERVICE Door Latch Assembly Door Latch Assembly in place Door Latch Removed for service ...
Страница 27: ...CONTROL PANEL SERVICE Door Latch Switch To Remove Switch first remove this pin Note position of spring ...
Страница 31: ...CONTROL PANEL SERVICE Power Switch Switch OUT OFF Switch IN ON ON Open Closed OFF Open Closed ...
Страница 32: ...TOE KICK REMOVAL 1 Remove Outer Door Panel 2 Remove 2 screws above panel 3 Remove 2 screws below panel ...
Страница 36: ...TANK OVERFILL Pump Motor ...
Страница 37: ...FLOAT SAFETY SWITCH Remove Screw Float Body held in place with screws through bottom plate ...
Страница 40: ...WATER LEVEL PRESSURE SWITCH Push the body of the switch up then pull straight out of the keyhole slot ...
Страница 45: ...HEATING ELEMENT Be certain gasket is in place when replacing heater ...
Страница 49: ...FILL VALVE SOLINOID Valve Body is Metric Thread U S adaptor provided on valve when unpacked ...
Страница 54: ...PUMP AND MOTOR ASSEMBLY Motor wiring connector Motor capacitor ...
Страница 57: ...UPPER WASH ONLY VALVE Ohmmeter test of the solenoid ...
Страница 63: ...www haieramericasupport com THANK YOU ...