Preparations before operation
Removing all package materials
Footing adjustment
Installation of
Clean the refrigerator before operation
Standing
Plug in
Including foam pedestal, adhesive tape (to fix accessories), and protection gaskets.
Stably adjust footing according to the ground condition to reduce possible vibration and noise.
Bumper bar
Take Bumper bar (2 pieces) outside from the operation manual bag; separately screw them in
M8 holes clockwise at middle and lower part of refrigerator back until they are fixed.
After being moved, the refrigerator should be standing for more than 30 minutes before being
connected to power.
Plug in to make a trial operation, then check the EMS display of temperature inside the
cabinet. If the temperature drops continuously without alarm, it means refrigerator runs
normally
As top-placed independent light canopy, products SC-310/410/510 can be disassembled;
Disassembly of top-placed independent light canopy.
Disassembly of Light canopy and instruction
Light canopy is at the front top. Screw off thumbscrews at left/right ends
Pull out connection terminal between light canopy and freezer, then the light canopy can be
disassembled
The processing of assembly is just the reverse to disassembly.
7
EMS-55 display
Equipment instruction
EMS-55 is a control system especially developed for Coca Cola Company. The
system consists of energy saving controller, transformer, and temperature sensing
probes (2), magnetic spring switch (2), and auxiliary lines.
By self-learning from ambient (population flow, open/close times of door and
working time etc), EMS_55, could establish automation module, with which it
could also adjust freezer operation status automatically to adapt to actual operation
mode.
This control system changes the traditional mode operated by temperature
controller, and makes it easy to operate and realizes automatic alarming,
meanwhile it also extends refrigerator's life, reduces the repair rate and achieves
energy saving.
Display instruction
Letters displayed on EMS have the following meaning
Note: At edition E43
it shows USE for EMS's operating status; At edition E46
it shows current temperature in refrigerator under normal operating status.
12