Haier PJF2-200 Скачать руководство пользователя страница 5

Haier solar water heater

 

    

5

Installation of Storage Water Tank

•  Determine  and install the storage water tank according  to the  requirement of users 

together with the actual situation.

•  Add one corrugated  pipe according  to the distance  between  the solar station and the 

storage water tank (it shall not be greater than 0.6m), to connect the circular outlet of the 

storage water tank and the circular inlet under the solar station.

•  Connect  with  various  pipe  fittings  at the temperature  pressure  valve, cold water inlet 

and hot water outlet.

•  Connect the temperature pressure valve on the water tank top. Connect a drainpipe 

on the valve. The drainpipe is to be installed in a continuously downward direction and 

in a frost-free environment. The valve can drain water out under high temperature and 

pressure condition to avoid hazards. At any time the drainpipe can’t be blocked.

•  The check valve shall be installed at the cold water inlet of the storage water tank, and the 

direction of the check valve shall be consistent with the water flow.

•  If the water temperature  in the storage  water tank rises, some water- drop  will  flow  out  

from  the  pressure  relief  hole  of  the  temperature pressure  valve, which is a normal 

situation.  If your water heater is not installed near to the sewer. It is suggested to install 

the drain pipe of the temperature  pressure valve, to prevent the spatter indoors. The 

drain pipe must be left open to the atmosphere. 

•   Connect the power cable of the storage water tank and the sensor to the correct position 

of the power panel for the solar station.

Installation introduction

Installation of the solar station 

1
2
3
4

Before  installation,  determine  the  specific  installation  position  according  to  the 

requirements  of user. 
According to the positions and distance of the hanger holes on the back of solar station,  

drill two holes in the wall with percussion  drill. The hole is 70mm in depth and 9mm in 

diameter. Then fix it on the wall with two expansion bolts. 

Align the hanger holes on the back of solar station to the hook on the hanger and hang the 

solar station on the hanger.
Screw off bolts on the bottom shell of solar station, open its front shell and connect it to 

the heat circulation  system (all the inlet and outlet vents of solar station are G1/2” female 

standard thread).

   

 

Notice

 

Installation position on the wall of 
installation hanger of solar station 

must be fixed properly and wall 

supporting  load  must  be  two 
times of weights of solar station.

The hanger holes on 

the back of solar station 

Hanger of 

solar station

Small expansion bolt

Содержание PJF2-200

Страница 1: ...use 2 Installation introduction 3 Installation Consideration 3 Installation of Solar Collector 3 Installation of StorageWaterTank 5 Installation of the solar station 5 Installation of expansion water...

Страница 2: ...onal personnel The water may drip from the discharge pipe of the temperature pressure valve and that this pipe must be left open to the atmosphere Children should be supervised to ensure that they do...

Страница 3: ...eze flows into underneath the inlet outlet pipeline and above of the inlet outlet pipeline Installation of Solar Collector Use the steel wire rope with the diameter of 6mm to install the solar collect...

Страница 4: ...ion tank Safety valve Priming valve Priming outlet Solar station Priming inlet Circulation liquid inlet of water storage tank Circulation liquid outlet of water storage tank Drain outlet outdoor indoo...

Страница 5: ...valve which is a normal situation If your water heater is not installed near to the sewer It is suggested to install the drain pipe of the temperature pressure valve to prevent the spatter indoors The...

Страница 6: ...equipment for priming Observe the returned antifreeze until uniform returned flow and no bubble is realized At first close the check valve connected to returning inlet of priming equipment then the c...

Страница 7: ...end Wire interface of water pump Relay output N end Relay output N label Water storage tank sensor interface Signal wire interface of Display board Creepage detection coil interface Clamp for holding...

Страница 8: ...connected points of lead must be avoided to be in outdoor environment to prevent corrosion and oxidation due to rain Schematic diagram of wiring position of solar collector temperature sensor unit mm...

Страница 9: ...presetted heating and intelligent heating At the same time indication light of corresponding mode is lighted up 2 second pause automatically confirms the mode and then enter the mode Press the button...

Страница 10: ...light turns green Intelligent heating indication light green red While the green light is on it is indicated that water heater is in intelligent heating working mode While the red light is on it is in...

Страница 11: ...erence is lower than 3 C then circulation pump stops working It is suggested that the set temperature difference of circulation pump shall be 15 C in summer and 8 C in winter Directions Q Q After sett...

Страница 12: ...heating mode the system will divide the whole day into 8 parts Record the period part with water usage times exceeding 4 in 7 days and in the 8th day finish the heating course before in the period par...

Страница 13: ...ar collector circular pipeline respectively Drain the storage water tank Close the inlet valve of the storage water tank Remove the end cap at the drain outlet Open the handle of the temperature press...

Страница 14: ...e water tank 200L 300L Waterproof level of storage water tank I PX1 Waterproof level of solar station I PX1 Rated internal pressure 0 70MPa Dimension of storage water tank mm 600 638 1250 600 638 1720...

Страница 15: ...se the electric heating method The pipe heater is damaged Contact the after sales service department The anti freezing fluid is not enough Fail to start the equipment It is not powered on the power su...

Страница 16: ...t name Quantity Packing box of storage water tank Storage water tank 1 Specification 1 Check Valve 2 Tee Valve 1 Temperature pressure valve 1 Large expansion bolt 4 3 4 fiber gasket 2 Stopper 2 Connec...