background image

Remedy  
Dismantle the system, remove the dry filter from it, purge the tubing with nitrogen, install a 
new filter, then evacuate it and finally charge it with refrigerant.  

C) Clogging in filter 

Analysis of Trouble 
Total clogging of a filter is rarely to occur. The paste-like matter formed from the substances 
filled into the system mostly causes this trouble or other dust after the refrigerator has been 
used for a longer time, or by the dirt accumulated gradually inside the filter. Sometimes, 
tapping the filter nay cause a passage for flowing, Touching it with your hand, you will feel 
that it is cooler compared with its temperature in the normal state. 

Remedy 
The same as described in the capillary clogging with dirt. 

3) Troubles of Compressor 

a) Breakage of gas suction and discharge valve blocks 

Analysis of Trouble  
The compressor works by means of the opening and closing of gas suction valve and 
discharge valve to suck and discharge the refrigerant. If the valve block is broken, the 
refrigerant can not be discharged, and hence no refrigerating can be achieved. 

Method for making judgement

It is quite difficult to differentiate this trouble from others because they often have similar 
symptoms. In repairing, firstly, hear attentively if there is some abnormal sound coming from 
the compressor (sometimes, the broken pieces of valve block may strike against the cylinder), 
and feel the compressor casing with your hand to ascertain whether it is too hot, this is also 
helpful to the troubleshooting; secondly, measure the pressures at the high and low pressure 
ports of the compressor with pressure gauges, if the gas suction valve block is broken, the 
suction pressure gauge pointer will swing violently and the suction pressure is very high, 
whereas when the gas discharge valve block is broken , the discharge pressure gauge pointer 
will swing drastically and the discharge pressure is very high. In the both cases, stop the 
compressor at once, and if technique is available, open the cylinder cover and check up the 
valve block, repair it, or replace it with a new one,  

C. Sudden stop of Compressor during Its Running  

The cause of sudden stop of a compressor during its running is mostly that the gas suction 
pressure and/or discharge pressure exceed their respective prescribed ranges, thus making a 
pressure-operated protective relay shut off the power to the compressor and stop it. In the 
following we discuss mainly the reasons for causing excessively high gas discharge pressure 
and low suction pressure. 

1) Stoppage due to excessively high gas discharge pressure 

Содержание PBFS21EDAW

Страница 1: ...access 3 Optimized condensing system 4 Pre cooling for defrosting for freshness storage 5 Automatic problem detecting and warning system door cooling warning system Haier Group 6 Vitamin C technology...

Страница 2: ...REFRIGERATION PRINCIPLE 9 System flow chart 9 4 CIRCUIT DIAGRAM 10 11 4 1 Schematic 10 4 2 Connect diagram 11 5 Sensor and Error code 12 6 TROUBLESHOOTING 13 30 6 1 Common Troubles in Refrigerators a...

Страница 3: ...PRODUCT CODE and SERIES INTRODUCTION Model Designations Bottom Mount 21 25 cu ft Refrigerator Freezer Details...

Страница 4: ...Gallon bottled seat Cooked IRRG ER Ice making drawer Deepfreeze refrigeration big drawer Deepfreeze fridge Ice spoon Ice maker Ice meeting drawer Drawer clapboard Deepfreeze fridge big drawer For the...

Страница 5: ...nge by means of hexagonal screwdriver and then remove the hinge Remove the door and place it in a proper position Remove the middle hinge if necessary 2 Removing and replacing the left door of refrige...

Страница 6: ...k Button D Time Area E K L M N K M N E Quick refrigerant button F G Deepfreeze fridge temperature adjusting button H deepfreeze fridge temperature indicating area I Chill cold storage temperature indi...

Страница 7: ...WHPSHUDWXUH DGMXVWPHQW Press Button J or Button K the chill cold storage temperature vision area will flicker and when the chill cold storage temperature is set the range of the chill cold storage tem...

Страница 8: ...apply for the models with the function of taking out cold drinks Only apply for the models without the function of taking out cold drinks F G H F G H RRU ERG YLVLRQ WLPH DGMXVWPHQW MXVW IRU 3 6 35 6 V...

Страница 9: ...out of the refrigerant quick deepfreeze refrigeration state KLOO FROG VWRUDJH TXLFN GHHSIUHH H UHIULJHUDWLRQ VHWWLQJ Press Button L the chill cold storage quick deepfreeze refrigeration button indica...

Страница 10: ...cold storage function is turn on again HOVLXV DKUHQKHLW VZLWFKLQJ IXQFWLRQ Press Button F and Button G and Button J on the vision board at the same time for three seconds the Celsius will be used aft...

Страница 11: ...pairing department to have the refrigerator repaired in order to test the optimizing controlling of the refrigerator When any door body is opened for over 60 seconds the door opening alarming function...

Страница 12: ...REFRIGERATION PRINCIPLE 1 Compressor 2 Mullion Heater 3 Dry Filter 4 condenser 5 Mullion Heater 6 Evaporator 7 Capillary tube SYSTEM FLOW CHART SYSTEM FLOW SCENOGRAPH...

Страница 13: ...CIRCUIT DIAGRAM 1 Schematic...

Страница 14: ...2 Connect diagram for PRFS25EDA series...

Страница 15: ...ice maker motor CN 6 Ice Maker CN9 Dispenser 1 neutral 1 2 damper heater CN 7 Drawer 9 10 light switch 7 8 temp sensor 5 dispenser arm switch 4 dispenser lamp 3 dispenser heater 2 Ice dispenser door...

Страница 16: ...VHQVRU DFN VLGH ZDOO RI UHH HU FRPSDUWPHQW PELHQW VHQVRU URXQGHG 8QGHU XSSHU KLQJH OHIW FRYHU HIURVW VHQVRU 7RS ULJKW FRUQHU HYDSRUDWRU FHPDNHU VHQVRU FHPDNHU IOH WUD K XPLGLW VHQVRU FXELF 8QGHU XSSHU...

Страница 17: ...al leak points do exist in the system In troubleshooting pay attention to those parts that are liable to leak check main connection points for oil seepage and tubing for cracks If there is no severer...

Страница 18: ...condition that the refrigerant in the system is unchanged This phenomenon occurs mostly when the compressor has been used for quite a long time its moving parts have worn to a considerable degree fit...

Страница 19: ...ring it thoroughly recharge the system with refrigerant and seal the charging port B No Refrigerating The phenomenon that the compressor runs normally but no frost or only a little frost appears on th...

Страница 20: ...s heard and the gas suction pressure rises as well it can be confirmed that the trouble is caused by ice clogging Remedy If there is too much moisture in the refrigerating system it is advisable to re...

Страница 21: ...similar symptoms In repairing firstly hear attentively if there is some abnormal sound coming from the compressor sometimes the broken pieces of valve block may strike against the cylinder and feel t...

Страница 22: ...od not too long thus making the protective relay actuate and bring to a stoppage Remedy Check up how the air has been left in the refrigerating system Generally there are two possibilities one is that...

Страница 23: ...s desired value the thermostat will shut down the compressor automatically Never take this normal operation as a trouble care should be taken to differentiate it from other real troubles in servicing...

Страница 24: ...rmal relay sometimes may be open due to the leakage of temperature sensing agent from the temperature sensor Remedy Remove the relay cover to check up its contacts if they are open this means that the...

Страница 25: ...the old with a new one d Check the terminals for loose connection and electric circuits for other abnormal phenomena 5 Mechanical faults of compressor a Seizing of shaft This phenomenon is caused most...

Страница 26: ...e to the fact that the contacts of the thermostat cannot be released Remedy Dismantle the thermostat and make a through checkup if it is totally out of functioning replace it with a new one 3 evaporat...

Страница 27: ...occurred in some electric devices or the erroneous wiring in installing power cord plug or outlet by the user This is very dangerous 3 Electric leakage test a Slight electric leakage A tingle sense wi...

Страница 28: ...loosening of parts Improper and compact laying of tubes or the loosening of parts may cause vibration and noise 4 Large noise of the fan a The fan motor is loose b Noise is produced by normal operati...

Страница 29: ...x the earth wire 1 1 Install top axis of mullion through the heater 2 Paste the heater onto mullion 2 4 4 Install the reinforce metal and foam on the bottom cover 5 Fix the bottom cover on the mullion...

Страница 30: ...and bottom cover 5 Remove the screw fixing earth wire 6 6 Tear off the heater and replace a new one Then Install it according to the steps above 5 3 Remove the screws on mullion 1 Remove the screws on...

Страница 31: ...will cause gap between the airproof and horizontal mullion 1 1 Remove the screws fixing horizontal mullion 2 2 Dismantle the horizontal mullion and foam airproof 3 3 Disconnect the linking clip and mu...

Страница 32: ...ce Place the sensor in middle of the clips Install the FRZ sensor according to the above steps 1 1 Remove the FRZ airpassage cover 2 2 Remove the rear gasket of FRZ airpassage cover then you can see t...

Страница 33: ...mm two thread and with electric iron plating soldering tin 4 connection port 4 connection electric iron pyr oconde nsation pipe Make pyrocondensation tube cover the two thread and with electric iron j...

Страница 34: ...ction of signal input terminal on Inverter PCB is right Notice right of signal input terminal is while the left is multimeter If it s wrong connection reconnect them 7 Test the output of control signa...

Страница 35: ...rtain time proportion if the humidity is heavy or more door openings 5 The Center mullion heater will stop working under proper humidity or less door openings 6 And it s 25W 529 There are the technica...

Страница 36: ......

Отзывы: