background image

                               

 

 

Cabinet. It is designed for freestanding installation only 

8. Do not operate your Wine cellar in the presence of explosive fumes. 

9. Do not damage the refrigerant circuit. 

10.Do not use any electrical device or any sharp instrument in 

defrosting your Wine cellar.

 

 

 

 

 

 

 

Содержание JC-298G

Страница 1: ...move roller Adjustable temperature display from 6 to 18 Active carbon deodorization implement Interior light Interior fan keep well proportioned temperature Store Wine quantity 120 bottle Haier Group MODEL JC 298G CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE ...

Страница 2: ... and ballast 11 5 4 The compressor 12 5 5 Fix the door 12 6 Control panel principle 13 7 System flow chart 14 8 System flow scenograph 15 9 Circuit diagram 16 10 1 Brief principle diagram 16 10 2 Connect diagram 17 10 3 Control panel diagram 18 10 4 Display board diagram 19 10 Normalproblems 20 11 T rouble shooting 23 11 1 Compressor does t start 23 11 2 poor cooling 24 12 Failure code display 25 ...

Страница 3: ...lways grasp the plug firmly and pull straight out from the outlet 4 Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length the plug or the connector end 5 Unplug your Wine cellar before cleaning or before making any repairs Note If for any reason this product requires service we s...

Страница 4: ...freestanding installation only 8 Do not operate your Wine cellar in the presence of explosive fumes 9 Do not damage the refrigerant circuit 10 Do not use any electrical device or any sharp instrument in defrosting your Wine cellar ...

Страница 5: ...ear 262 8 Defrosting H manual A automatic Fridge Freez A Frost free system Defrost water outlet Ye s Air circulating ventilator Yes Kind of coolant R134a R600a R600a Foaming components CP IP 3 Technical data Voltage frequency V Hz 220 240 V 50 Input power mains fuse minimum W A 160W 1 10A Length of cable incl plug cm 200 205 Temperature range from to Fridge Freez C 6 18 Features DI N 8950 resp 895...

Страница 6: ...terior Ex terior Control lamps green yellow red Over temperature ALARM LED acoustic acoustic Adjustable thermostat Yes Fast freeze switch _ Interior light W 11 Adjustable feet front rear n front Castors front rear rear Wall spacer grid distance holder Flush back cm 10 10 10 6 Product dimensions Unit dimensions H W D cm 128 66 5 67 Depth with open door cm 132 Net weight kg 69 0 7 Packing dimensions...

Страница 7: ...ellar on a floor strong enough to support it fully loaded 3 When moving the Wine cellar never tilt it more than a 45 degree angle Thi s could damage the compressor and the sealed system 4 If the Wine cellar is tilted let it st and in an upright position for at least 24 hours prior to plugging This is to allow the refrigerant to settle Proper Air Circulation z To assure your W ine cellar works at t...

Страница 8: ...ated e g garage etc your wine cellar was not designed to operate i n temperature settings below 32 Fahrenheit z Select a suit able location for the wi ne cellar on a hard even surfaces away from direct sunlight or heat source e g radiator s baseboard heaters cooki ng appliances etc Any floor unevenness should be corrected Initial Setup 1 Operating Your Wine cellar Once the wine cel lar is in i ts ...

Страница 9: ...e a sharp or metallic instrument to remove the frost as it may damage the cooling coils A punctured coil will void the warranty Unplug the power pin then take out stored wine and place in a safety place Defrosting usually takes a few hours To defrost faster keep the freezer door open When frost buildup has melted wipe water of f with a dry cloth Replace the electrical plug in the electrical outlet...

Страница 10: ...n the top b Hold the control panel meanwhile push Hinge the door should open for 135 when the wiring harness button with your loosening the right side philip screw thumb to take the control wire apart Control panel Fan and evaporator clapboard Glass door Adjustable feet Handle ...

Страница 11: ...ever pull it wildly without pushing the button That will break it f The disply panel is fixed on the plastic panel with three philip screws you should regulate the philip screw properly to make the button on the disply panel sensitive On the right side of the picture is fan switch you can connect it directly with the wire without thinking of the direction but remember to push the button on the wir...

Страница 12: ...and control wire in the Ballast cover is fixed in the slot with accesso ry In the picture is the plug connecting the control wire and power wire The black one is ballast wire spring out from the Cord stopper cover d Take the Philip screw ap art from the ballas then you can t ake the ballas ap art When assembling it please fix the below screw first e The ballast wire has locked oneself port When ch...

Страница 13: ...and the compressor the live wire and zero wire is connected also some anti shock material to the compressor power panel rotate the plastic bolt to fix between them the wire The compressor power panel is one whole part 5 Fix the door a Pull the bottom Hinge cover out flatly b The bottom Hinge is fixed with four bolts you should use a M6 sleeve to unfix it then you can take the door out ...

Страница 14: ...ressing the temperature buttons about 3 seconds the set temperature will flash on the display To reduce the temperature press the bottom button To increase the temperature press the top button 2 The small yellow lamp is the LAMP switch When the lamp is on the Interior light will run 3 The small red lamp is the ALARM lamp When the lamp is on the alarm will be on ...

Страница 15: ...The refrigeration system of direct cooling single system cooler belongs to the category of a single temperature and single control refrigerating system with one evaporators and is controlled by a single temperature control ...

Страница 16: ...15 System flow scenograph ...

Страница 17: ...time wait 24 hours before plugging the unit in 2 The alarm will sound when the appliance is switched on for the first time and when the appliance is warm Press the Alarm button to switch it off The temperature display will also flash until set temperature is reached 3 The appliance has been tested and is supplied set for normal operation of 12 C ...

Страница 18: ...17 2 Connect diagram ...

Страница 19: ...0UF 25V C2 104 E2 100UF 16V N L C HEAT LAMP K2 5A K3 5A K1 16A Vin 1 GND 2 Vout 3 IC1 7805 L L L 12V 12V 12V 12V 5V 5V 1 2W R7 120 CX1 103 275VAC 1 2 3 4 5 CN1 B5P9 VH 1 2 3 4 5 CN2 5267 5A N1 9013 N2 9013 N3 9013 D5 4148 D6 4148 D7 4148 R6 2 2K R4 2 2K R2 2 2K R5 10K R3 10K R1 10K C HEAT LAMP ...

Страница 20: ...B4 22 D2 AD9 23 D5 T1C1 24 D4 T1C0 25 A5 KB5 26 RST 27 A7 KB7 28 AD12 T2CLK 29 IRQ 30 A0 KB0 31 VSS 32 IC1 MC68HC908JL8CFA C1 G F A B D H E C C2 LED1 TOT 5371 C2 22 R26 10M R42 220 R41220 R40220 R39220 R43 220 R44 220 R45 220 R46 220 N1 2SC2412K N3 2SC2412K R15 4 7K R16 4 7K G F A B D H E C N2 2SC2412K N4 2SC2412K LED2 LED3 R17 4 7K R18 4 7K D1 RLS4148 D2 RLS4148 D3 RLS4148 D4 RLS4148 R19 2K R20 1...

Страница 21: ...vometer if ther e is wire broken change compressor 8 Change compressor 9 Change compressor Compress or st arts too frequent operation time too long but temperatu re drop in wine cellar is too slow 1 The point of sensor was moved 2 The temperature controller is out of order 3 The environment temperature is too high humidity too high airflow is impeded 4 The frost layer at the evaporator is too thic...

Страница 22: ...oor is loose 2 The wine cellar body is not stable and in level 3 When compressor runs friction between tubes and wine cellar body causes resonance 4 Compressor fix ing screw is loose 5 The vibration absorption cushion for comp ressor fixing is too tight or too loose or ageing 6 Compressor inside noise is too big or vibration absorption suspending spring is broken 1 Reinforce the floor 2 Make the w...

Страница 23: ... dust 3 Make the temperature dry and control the environment humidity Tempera ture controlle r out of order 1 There is leakage of temperature sensing medium 2 Damage of cam of cont acting point spring etc Change temperature controller The probe of temperat ure sensing tube doesn t contact evaporat or well It has not been mounted to position or changed during transportation Mount it again ...

Страница 24: ...3 Trouble shooting 1 Compressor does t st art ...

Страница 25: ... room temperature is too hoot or not Whether the condenser is blocked by cloth pieces or paper or dirt or not Whether the glass door has been closed well Whether the glass door door seal bar is too dirty or sealed well Remove dirt and put on a little talcum power Avoid these matters which will affect heat radiation of condenser and reduce refrigeration ability Frequent opening and extended opening...

Страница 26: ...e broken circuit or open circuit it shows F3 Red indicator is light with buzzing Compressor enter into protection mode stop cooling Check sensor A and sensor B and their connecting status replace sensor if necessary F4 Continuous compressor running time is more than 3 hours and Sensor B felt the inner temperature change is within 1 Compressor enter into protection mode stop cooling Check if sensor...

Страница 27: ......

Отзывы: