7- -
1 2
.
No draining
No
No
After insert the plug, turn the
sequencer knob to the drain location
Check the inset is normal
and measure the voltage of two ends of
the drain pump
Check the inset is normal
and measure the voltage of two ends of
the drain motor
Replace the drain pump
Check if the drain pump acts.
Check if the drain motor is normal
Check if the wire unit is normal
No
Yes
No
No
Check if the wire unit is normal?
Replace the sequencer
Replace the sequencer
Repair or replace the wire unit
Yes
Yes
Yes
7- -
1 3
.
Keep filling water
Open the water faucet without switching on the power.
If the water can fill into the water inlet valve.
check if the gas guide system such
as gas cell leaks gas
Replace the water inlet valve.
Replace the water level sensor.
It leaks gas. Please check and repair the gas guide system.
Please smear 801 glue in installation of the connecting pipe.
Please smear 801 glue in installation of the gas cell cover.
No
No
Exist
Exist
Exist
-
17
-