Troubleshooting
18
S/N
Possible
Malfunctions
Possible
causes
Checking Steps
Instrument
Solutions
1. Check whether the tap is
open.
Eyeballing
If normal, go on with the next
step.
2. Check whether the water
pressure is too low.
Eyeballing
If normal, go on with the next
step.
3. Check whether the
electromagnetic valve is well
linked.
Eyeballing
If normal, go on with the next
step.
4. Check whether the
pressure switch is well linked.
Eyeballing
If normal, go on with the next
step.
5. Check whether the
pressure switch hose leaks
gas or not.
Eyeballing
Blowing
If normal, go on with the next
step.
6. Check whether the
electromagnetic valve is
damaged.
Check by
hand
Eyeballing
Multimeter
If normal, go on with the next
step.
7. Check whether the
pressure switch is damaged.
Eyeballing
Multimeter
If normal, go on with the next
step.
9 Err5
Alarm
The water
switch does
not move
within 8
minutes.
8. Check whether the relevant
wiring harness is broken.
Eyeballing
Multimeter
If normal, change power
drive board.
1. Check whether the motor is
well linked.
Eyeballing
If normal, go on with the next
step.
2. Check whether the motor is
damaged ( or over-heated ).
Eyeballing
Multimeter
If normal, go on with the next
step.
10
Err6, Err7,
FErr Alarm
The motor is
broken.
3. Check whether the relevant
wiring harness is broken.
Eyeballing
Multimeter
If normal, change power
drive board.
1. Check whether the
drainage pump is well linked.
Eyeballing
If normal, go on with the next
step.
2. Check whether the
drainage pump is damaged
(short circuit inside).
Eyeballing
Multimeter
If normal, go on with the next
step.
3. Check whether the
pressure switch is well linked.
Eyeballing
If normal, go on with the next
step.
4. Check whether the
pressure switch is damaged.
Eyeballing
Multimeter
If normal, go on with the next
step.
5. Check whether the
pressure switch hose leaks
gas or not.
Eyeballing
Blowing
If normal, go on with the next
step.
11 Err8
Alarm
The water
level is over
the
protecting
water level.
6. Check whether the relevant
wiring harness is broken.
Eyeballing
Multimeter
If normal, change power
drive board.
Содержание HT1206TXVE
Страница 6: ...Safety caution 6 ...
Страница 7: ...Safety caution 7 ...
Страница 8: ...Safety caution 8 ...
Страница 9: ...lnstallation 9 lnstallation 9 ...
Страница 10: ...Installation 10 ...
Страница 11: ...Functions 11 ...
Страница 12: ...Functions 12 ...
Страница 13: ...Function schedule 13 ...
Страница 14: ...Function schedule 14 Function schedule 14 ...
Страница 15: ...Troubleshooting 15 ...
Страница 19: ...Wiring circuit 19 ...
Страница 20: ...Exploded view and list of parts 20 Exploded view 78 77 ...
Страница 23: ...Exploded view and list of parts 26 Sincere Forever Haier Group Tel 86 532 88939999 Web site http www haier com ...