Haier HSU30HEA03/R2 Скачать руководство пользователя страница 6

Before disposing an old air conditioner that

goes out of use, please make sure it's inop-

erative and safe. Unplug the air conditioner

in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system

 contains refrigerants, which require speciali-

zed waste disposal. The valuable materials

contained in an air conditioner can be

recycled.Contact your local waste disposal

center for proper disposal of an old air

conditioner and contact your local authority

or your dealer if you have any question.

Please ensure that the pipework of your air

conditioner does not get damagedprior to

being picked up by the relevant waste

disposal center, and contribute to environ-

mental awareness by insisting on an

appropriate, anti-pollution method of disposal.

Cautions

Disposal of the old air conditioner

All the packaging materials employed in the

package of your new air conditioner may be

disposed without any danger to the

environment.

The cardboard box may be broken or cut into

smaller pieces and given to a waste paper

disposal service. The wrapping bag made of

polyethylene and the polyethylene foam pads

All these valuable materials may be taken to

a waste collecting center and used again after

adequate recycling.

Consult your local authorities for the name

and address of the waste  materials collecting

centers and waste paper disposal services

nearest to your house.

Disposal of the packaging of your

new air conditioner

Before starting the air conditioner, read the

information given in the User's Guide caref-

ully. The User's Guide contains very impor-

tant observations relating to the assembly,

operation and maintenance of the air

conditioner.

The manufacturer does not accept respon-

sibility for any damages that may arise due

to non-observation of the following

instruction.

    Damaged air conditioners are not to be

put into operation. In case of doubt, consult

your supplier.

   Use of the air conditioner is to be carried

out in strict compliance with the relative

instructions set forth in the User's Guide.

   Installation shall be done by professional

people, don't install unit by yourself.

    For the purpose of the safety,the air con-

ditioner must be properly grounded in acco-

rdance with specifications.

    Always  remember  to unplug the air

conditioner before openning inlet grill. Never

unplug your air conditioner by pulling on

the power cord. Always grip plug firmly and

pull straight out from the outlet.

    All electrical repairs must be carried out

by qualified electricians. Inadequate repairs

may result in a major source of danger for

the user of the air conditioner.

Safety Instructions and Warnings

     Do not damage any parts of the air

conditioner that carry refrigerant by piercing

or performating the air conditioner's tubes

with sharp or pointed items, crushing or

twisting any tubes, or scraping the coatings

off the surfaces. If the refrigerant spurts

out and gets into eyes, it may result in

serious eye injuries.

1

Содержание HSU30HEA03/R2

Страница 1: ...HSU30HEA03 R2 DB OPERATING MANUAL ROOM AIR CONDITIONER WALL MOUNTED TYPE Please read this operation manual before using the conditioner Keep this operation manual for future reference NO 0010521199...

Страница 2: ...tioning product is marked with this sym bol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dis mant...

Страница 3: ...los productos el ctricos y electr nicos no deben mezclarse con el resto de resi duos dom sticos no clasificados No intente desmontar el sistema usted mismo El des mantelamiento del acondicionador de...

Страница 4: ...oduct 2 the additional refrigerant amount charged in the field and 1 2 the total refrigerant charge on the refrigerant charge label supplied with the product The filled out label must be adhered in th...

Страница 5: ...refrigerante cargado en campo y 1 2 la carga total de refrigerante En la etiqueta de carga de refrigerante suministrada con el producto La etiqueta rellenada debe pegarse cerca de la conexi n de carga...

Страница 6: ...nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s Guide contains very...

Страница 7: ...should be in line with the local wiring standard 5 After installation the power plug should be easily reached 6 The waste battery should be disposed properly 7 The appliance is not intended for use b...

Страница 8: ...e Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a ina...

Страница 9: ...ially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occ...

Страница 10: ...inlet grille may vary from the one shown in the manual according to the product purchased Display board Inlet Air Purifying Filter Horizontal flap adjust up and down air flow Don t adjust it manually...

Страница 11: ...9 POWER SOFT button 6 Use to set power soft function Used to select CODE A or B with a press A or B will be displayed on LCD Please select A without special explanation 1 CODE When the remote controll...

Страница 12: ...acle as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver...

Страница 13: ...ctively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room When the fan in the indoor unit...

Страница 14: ...Press ON OFF on the remote controller unit starts 2 Select operation mode Press MODE button For each press operation mode changes as follows Remote controller Then Select Auto operation Press FAN butt...

Страница 15: ...ase 1o C if kept depressed it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed sele...

Страница 16: ...dly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON...

Страница 17: ...en Select FAN operation 3 Fan speed selection 4 Unit stop About FAN operation In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mod...

Страница 18: ...crease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops AUTO LOW MED HI AUTO COOL...

Страница 19: ...tion on remote controller displays as follows according to different operation modes remote controller COOL DRY FAN remote controller remote controller The vertical flap will swing according to the ab...

Страница 20: ...operation stops SLEEP operation starts SLEEP operation stops Approx 6hrs 1 hr 1 hr 1 hr 3 hrs 3 hrs Rises 1O C Rises 1O C Rises 1O C Temp setting Temp setting Unit stop Unit stop In COOL DRY mode In...

Страница 21: ...nges as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every time the button i...

Страница 22: ...Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting decreases 1 min i...

Страница 23: ...time the button is pressed display changes as follows Stop the display at SOFT BLANK In POWER operation status Selecting of SOFT operation Press POWER SOFT button again POWER SOFT disappears To cance...

Страница 24: ...operation the system automatically selects the operation modes cooling or heating according to the room temperature Test operation Test operation switch is the same as emergency switch Use this switch...

Страница 25: ...eration prevent the penetration of direct sunlight with curtain or blind Close doors and windows during operation If the unit is not to be used for a long time turn off the power supply main switch OF...

Страница 26: ...at the filter is completely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use...

Страница 27: ...r will be used based on real situation The photocatalyst air purifying filter will be solarized in fixed time In normal family it will be solarized every 6 months Prop up the inlet grille by using a s...

Страница 28: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Страница 29: ...e plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may ca...

Страница 30: ...ve elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a sw...

Страница 31: ......

Отзывы: