WARNING

If anything abnormal such as a burning smell occurs, stop the 
operation immediately and turn the breaker off.

Close doors and windows (preferably use a curtain) while 
operating air conditioner for a long time, if room air is quite 
turbid, you could open the door and window for a moment 
to get some fresh air outside.

Do not install the air conditioner at places where flammable 
gas may leak. If there is electrical leakage accidentally from 
air conditioner, it is easy to cause fire or explosion.

Do not apply the unit for special purposes. Do not use to store 
precision equipment, food, painting etc, which require certain 
humidity and temperature, for their quality may be affected.

Do not open windows and doors while operating the air 
conditioner at COOL/DRY mode for a long time under high 
humidity condition (above 80%). Otherwise, condensed 
water may drip from the unit.

The appliance shall be installed in accordance with national wiring regulations.
The appliance must not be installed in the laundry.
The appliance must be installed 2.3m above the floor.
The appliance must be positioned so that the plug is accessible.
For some models whose cooling capacity are above 4600W (17000BTU/h), 
an all-pole disconnection device which has at least 3mm separation distance in 
all pole and a residual current device(RCD)with the rating of above 10mA shall be incorporated
 in the fixed wiring according to the national rule.

Do not insert a finger, a rod or any other objects into the air 
outlet/inlet grille. As the fan is running at a high speed, it will 
cause injury.

SAFETY PRECAUTION

Do not use these stuffs for cleaning: 
chemical solvent, insecticide, inflammable spraying 
materials which will damage the appearance of air 
conditioner. Do not sprinkle water directly on the indoor unit. 

This product must not be disposed together with the domestic 
waste. This product has to be disposed at an authorized place 
for recycling of electrical and electronic appliances.

Содержание HSU-09LA10 - annexe 1

Страница 1: ...SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER S MANUAL Thank you for choosing our Air Conditioner Please read this OWNER S MANUAL carefully prior to use and keep it for further reference ...

Страница 2: ...2 2 6 6 Safety Awareness Name of Parts Service and Maintenance Trouble Shooting Performance Parameters 7 7 4 4 9 9 CONTENTS 1 1 Contents 1 1 ...

Страница 3: ... to another cord or by using an extension cord Do not put any other loads on the power supply socket An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks SAFETY PRECAUTION The following pictures are presented just for the purpose of illustration As for some models whose cooling capacity is above 4600W 17000BTU h their power cables do not have a plug So p...

Страница 4: ...he appliance shall be installed in accordance with national wiring regulations The appliance must not be installed in the laundry The appliance must be installed 2 3m above the floor The appliance must be positioned so that the plug is accessible For some models whose cooling capacity are above 4600W 17000BTU h an all pole disconnection device which has at least 3mm separation distance in all pole...

Страница 5: ...UNIT NAME OF PARTS 4 4 Connecting pipe Drain hose Air inlet Air outlet Drain opening Manual operation Left Right deflector Filter Air inlet Deflector Display Front panel Appearance of the indoor unit and outdoor unit may differ with some models NOTICE Time indicator lamp Setting temperature and timer display Sleep indicator lamp HEAT PUMP MODE indicator lamp COOL MODE indicator lamp ...

Страница 6: ...OP The following table shows the condition of settemperature fan speed and deflector during emergency operation 4 HORIZONTAL LOUVER BLADE Hold the knob and move the deflector to change right left airflow direction Be careful not to adjust the deflector during operation as the fan is rotating at a high speed and may pinch your fingers Mode Set temperature Deflector Fan speed Swing Swing Heating Hig...

Страница 7: ...r detergent insecticide etc as they can damage the units Don t tear the batteries apart or throw them into fire which will lead to explosion FAN OPERATION Clean the front grille and air filters at least once in every two weeks Before cleaning be sure to stop the operation and turn off the breaker In this illustration each section is shown just for the purpose of explanation During operation please...

Страница 8: ...re there any obstacles to block the inlets and outlets of the indoor and outdoor units Is sleep mode used during daytime Is the indoor fan speed set low Are doors and windows closed The power supply may be suddenly cut off when the power is normal again the air conditioner will automatically resume the same mode operation as setting before power failure This is called auto restart function and thi...

Страница 9: ...d again blows out Outdoor unit leaks water During cooling connecting pipe or pipe connector will cause the moisture content condensation due to the low temperature During heating or defrosting melting water and water vapor will run out During heating water on heat exchanger will drop Is there a fault Fault analysis If you find one of the following symptoms please turn the breaker off quickly and c...

Страница 10: ...7 DB 19 WB 15 WB 24 WB 6 WB 5 Wiring diagram of air conditioner indoor unit outdoor unit are attached to the indoor outdoor unit respectively 27 DB Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor side DB WB Outdoor side DB WB C C 32 23 21 15 27 20 43 26 21 15 24 18 5 6 3 Due to the policy of constant development we reserve the right to modify technical data without notice Wh...

Страница 11: ...KGS 04 ...

Отзывы: