NOTE:
If unforeseen circumstances create conflict between the following servicing
precautions and any of the safety precautions, always follow the safety precautions.
Remember : Safety First.
General Servicing Precautions
1. Always unplug the receiver AC power cord from the AC power source before:
a. Removing or reinstalling any component, circuit board module or any other
assembly of the receiver.
b. Disconnecting or reconnecting any receiver electrical plug or other electrical
connection.
c. Connecting a test substitute in parallel with an electrolytic capacitor in the
receiver.
CAUTION:
A wrong substitution part or incorrect installation polarity of
electrolytic capacitors may result in an explosion hazard.
d. Discharging the picture tube anode.
2. Test high voltage only by measuring it with an appropriate high voltage meter or
other voltage-measuring device (DVM, FETVOM, etc.) equipped with a suitable
high voltage probe. Do not test high voltage by “drawing an arc”.
3. Discharge the picture tube anode only by (a) first connecting one end of an
insulated clip lead to the degaussing or kine aquadag grounding system shield at
the point where the picture tube socket ground lead is connected, and then (b)
touch the other end of the insulated clip lead to the picture tube anode button,
using an insulating handle to avoid personal contact with high voltage.
4. Do not spray chemicals on or near this receiver or any of its assemblies.
5. Unless specified otherwise in this service manual, clean electrical contacts only
by applying the following mixture to the contacts with a pipe cleaner, cotton-tipped
stick or comparable nonabrasive applicator; 10% (by volume) Acetone and 90%
(by volume) isopropyl alcohol (90%-99% strength)
CAUTION:
This is a flammable mixture.
Unless specified otherwise in this service manual, lubrication of contacts is not
required.
6. Do not defeat any plug / socket B+ voltage interlocks with which receivers
covered by this service manual might be equipped.
7. Do not apply AC power to this instrument and/or any of its electrical assemblies
unless all solid-state device heat sinks are correctly installed.
8. Always connect the test receiver ground lead to the receiver chassis ground
before connecting the test receiver positive lead.
Always remove the test receiver ground lead last.
6
Содержание HS-2190
Страница 31: ...Note the item marked have been adjusted on product line those may differ in different TV 31 ...
Страница 40: ...Terminal view of transistors 2SC4237 2SD1879 2SA608 2SC536 2SB764 2SD400 40 ...
Страница 43: ...C Circuit diagrams 43 ...
Страница 61: ...Sincere Forever Haier Group Tel 86 532 8938356 Web site http www haier com ...