5-7. Water inlet quantity setting
(1) If there is phenomenon such as ice box leakage, ice cubes stick together, over-size ice cubes, it
means that the water volume is more than necessary. Need reduce the water time to small.
(2) Adjust S1 on the main control board (as shown on picture), the following table is a comparison of
time and parameter.
Parameter
No.
S1 S2 S3
timing
remark
1 OFF OFF OFF
6sec
2 ON OFF OFF 3.5sec
3 OFF ON OFF 4.0sec
4
ON ON OFF 5.0sec
5
OFF OFF ON
5.5sec
6
ON OFF ON 6.0sec
7
OFF ON ON
7.0sec
8
ON ON ON
8sec
Volume is
80-120cc