Operating functions
Installer settings
Parameters
,
Description
- To open the installer settings, press s
system, then press and
at the same time for 10 seconds.
- When menu is open, press or to change the value of the settings.
- Press to c
ttings.
- Press to close the menu.
O -peak signal type
logic
●
type
When you use o -peak time clock contr
rst determine
the type of signals,Only allow professional installers to operate.
- In
●
two ways using heat pump,should set in the installer
settings
-01 manually set o -peak time;
-02 switch signals by power companies.
-03 PV signal
●
-04 SG signal.
NO
01
ON
8h
5-10h
NO , NC
01 , 02
03 , 04
ON , OF
/
d1-d7
Set the day of the week
,
,
Factory
setting
Adjustment
range
Avoid Legionella
- This parameter is used to activate the legionella protection
mode.
- Once every 7 days, all domestic hot water is heated to 65°C.
- Set the day of the week, d1 to d7 for Monday to Sunday, and
remember the day of the week.
- NO corresponds to Normally Open Signal.
- NC corresponds to Normally Close Signal.
23
Compressor maximum continuous working time
- If the maximum continuous working time of the compressor
more than Set Time, start auxiliary power.
-
,
-
Auxiliary Heating in o -peak time
- ON corresponds to turned on auxiliary Heating.
- OF corresponds to turned o auxiliary Heating.
,
ON
ON , OF
E
n
g
lis
h
Содержание HP80M5
Страница 18: ...Installation introduction 18 Power cable 3 1 5mm 2 2 0 75mm2 Black wire 16A Auto 1 0 123kwh 1 0 ...
Страница 27: ......
Страница 28: ...0040510083 20210218 V ...